Showing results: 6496 - 6510 of 7546 items found.
-
Series 41-760 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
41-761-002 -
Pickering Interfaces Ltd.
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
41-761-001 -
Pickering Interfaces Ltd.
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
41-760-002 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
41-760-001 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
41-760-003 -
Pickering Interfaces Ltd.
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
40-597A-105 -
Pickering Interfaces Ltd.
The 40-597A-105 is a PXI 1-pole 160x12 matrix in BRIC8 format and is part of a range of high density matrix modules able to switch up to 2 A or 200 VDC/210 VAC. The 40-597A BRIC modules are available in 2, 4 or 8-slot sizes to suit most high performance PXI matrix requirements, constructed using high quality electro-mechanical relays for high switching confidence.
-
40-585-001 -
Pickering Interfaces Ltd.
Our model 40-585, along with the following models40-584, 40-586A, 40-587Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
40-592A-116 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units.
-
40-795-001 -
Pickering Interfaces Ltd.
The 40-795/796 Daisy Chain Switching Module is designed for telecom test applications. It allows production or verification testing of SONET/SDH transmission multiplexers switching 2MBit/s or 1.5MBit/s data over 100 or 120 balanced lines.
-
41-761-003 -
Pickering Interfaces Ltd.
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
40-923A-001 -
Pickering Interfaces Ltd.
The 40-923A includes all the features and performance required by the PXI standard and supports a control interface or embedded controller and up to 18 additional 3U peripheral modules.
-
40-924-001 -
Pickering Interfaces Ltd.
The 40-924 includes all the features and performance required by the PXI standard and supports a control interface or embedded controller and up to 7 additional 3U peripheral modules.
-
42-297A-140 -
Pickering Interfaces Ltd.
The 40-297A-140 (PXI) and the 42-297A-140 (PXIe) are 3-channel programmable resistors with a range of 2.5 Ω to 102 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
42-297A-121 -
Pickering Interfaces Ltd.
The 40-297A-121 (PXI) and the 42-297A-121 (PXIe) are 4-channel programmable resistors with a range of 1.5 Ω to 925 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.