Showing results: 6526 - 6540 of 7546 items found.
-
42-297A-013 -
Pickering Interfaces Ltd.
The 40-297A-013 (PXI) and the 42-297A-013 (PXIe) are 18-channel programmable resistors with a range of 1 Ω to 238 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
310120219 -
Virginia Panel Corporation
Receiver, G40x, 48 Module, Slide Mount, EMIThis model replaces G40x p/n 310120163 which was the same, but not EMI.The G40x is a two-tier, 48 slot system that accommodates pull through removal of interconnect adapters with VPC modules, PCBs/ Wiring, and test cards in one piece. It offers 8 standard/90 Series discrete-wire module slots, plus space for 2 iCon series modules, as needed. This G40x is for slide mounting. The operation handle may be switched from the standard right side to the left. Slide kit and flange mounting kit purchased separately.
-
40-261-001 -
Pickering Interfaces Ltd.
PXI programmable resistors featuring fine resistance setting resolution and excellent resistance stability and accuracy through the use of advanced switching networks and software correction techniques. The two modules in this range support two identical resistor channels t that can be set to values of between 1.5Ω to 2.9kΩ or 10Ω to 36kΩ with a precision of better than 2mΩ (this version) or 15mΩ (40-261-002) making them ideal for simulating sensors that can be accurately controlled to fine values.
-
42-297A-050 -
Pickering Interfaces Ltd.
The 40-297A-050 (PXI) and the 42-297A-050 (PXIe) are 6-channel programmable resistors with a range of 3 Ω to 1.51 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
42-297A-010 -
Pickering Interfaces Ltd.
The 40-297A-010 (PXI) and the 42-297A-010 (PXIe) are 18-channel programmable resistors with a range of 1 Ω to 31 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
40-262-202 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-263-303 -
Pickering Interfaces Ltd.
The 40-263-303 is a 12-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
40-263-301 -
Pickering Interfaces Ltd.
The 40-263-301 is a 12-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
42-158-103 -
Pickering Interfaces Ltd.
The 40/42-158-103 is a PXI/PXIe high density power relay module with 16xSPDT switches rated at 5A. User connection is via a 50-pin D-type male connector.
-
40-262-101 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-262-102 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-263-003 -
Pickering Interfaces Ltd.
The 40-263-003 is a 24-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
40-263-001 -
Pickering Interfaces Ltd.
The 40-263-001 is a 24-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
40-263-102 -
Pickering Interfaces Ltd.
The 40-263-102 is a 20-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
40-263-501 -
Pickering Interfaces Ltd.
The 40-263-501 is a 4-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.