  • Manual Oscillators

    MOS-01, -01A - Compact Power Company

    The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.

  • Multiple Output Bidirectional PSU

    LAB-MOBI - Electronic Test & Power Systems

    The LAB-MOBI is a series of multi channel High Power Bidirectional PSUs. Each system is able to operate as either a DC Source or a DC Electronic Load. This integrated approach features high dynamics enabling the user to switch seamlessly between quadrants. When sinking energy from the unit under test the LAB-MOBI automatically inverts the DC to AC and synchronises this output to the grid. Dedicated application modes are available for battery cycling and emulation, which can be used to implement specific test routines. Other common applications the LAB-MOBI is used for include testing electric motors, fuel cells, super capacitors and solar panels. Max. Volt. Output 1000V,Min. Power 60kW, Max. Power 500kW.

  • On-Board Flow Meter

    DF-2200 - Ono Sokki

    The DF-2200 On-Board Flow Meter is a compact on-board fuel flow meter developed for our FP series Volumetric Flow Detector*. The compact body is equipped with functions such as flow rate/temperature/pressure measurement and CAN communication required for fuel consumption measurement. Adopting the same size as our CT-6700 Engine Tachometer, it can be used by stacking two units in a limited space. In addition to 12 to 24VDC of power source, an AC adapter is available as an option, which is sufficient for not only on-board measurement but also engine bench evaluation.

  • Solenoid-Saver

    B-1022-B - ROSS ENGINEERING CORPORATION

    *Solenoid-Saver® eliminates AC hum and reduces heat generation for many types of solenoids.*Controlled application of current prevents coil burnout if high pull-in/low holding current AC or DC solenoids fail to pull-in completely.*Can adapt high pull-in low holding current solenoids to special voltages & frequencies 12V to 250V DC or 12V to 240V AC wideband 25-800Hz.*Optional optical isolated control input 4 to 10V, 5MA, 20 usec or more (or other control voltages) to actuate any high current solenoid directly by computer or other low power signal source.*For coils of 1 ohm to 3,500 ohms DC resistance requiring up to 70 amps during pull-in up to 120 milliseconds. Basic solenoid coil voltage and resistance must be specified.*Eliminates heat producing dropping resistors, bypass switch, dual coils, laminations, & shading coils.*Can increase pull-in and holding force of many types of solenoids.*Optional stored energy to delay solenoid release on loss of power.*Can be used as an added accessory to existing solenoid installation to eliminate AC hum, lower coil temperature and prevent coil burnout.*Optional high speed, 1 microsecond sensing, 1-10 millisecond actuation with stored energy Solenoid-Saver®

  • Power Supply Testers

    Qmax Test Technologies Pvt. Ltd.

    Power Supply Tester is an integrated package of hardware such as AC/DC Power Sources, DC Loads, Noise Measurement Unit, and DMM etc configured as per user applications, which makes it suitable for testing wide range of Power Supplies and provide economic solution for testing AC/ DC and DC/DC power supplies and converters. The Power Supply Boards that passed in the first level of screening for Go-No Go tests will undergo a second level testing. The second level of testing measures all the key parameters of the power supply such as line regulation, load regulation, efficiency etc and check whether the results are within the mentioned limit, if not declare the UUT (Power Supply Board Under Test) as a failed one.

  • Car Accessories Material Burning Tester

    ZRS-4H - Lisun Electronics Inc.

    • Test Gas Source: Gas or Liquefied Petroleum Gas (Suggestion: Use good quality gas if possible) • Burner inner diameter: ¢9.5±0.5mm, about 100mm long with air adjusting hole • Height of flame: Can be adjusted from 20 mm to 100 mm according to the standard requirement • Applying time of flame: Burning time can be adjusted from 0 to 99 minutes 99 seconds • Test process: Automatic control • Inner volume: 0.05m³ • Material: Stainless steel or iron plate spray • Power: AC 220V; 50Hz/5A

  • Digital Multimeter and Phase Rotation Tester

    3000 MPR - Standard Electric Works Co., Ltd

    ● 4000-count LCD● Auto ranging● Voltage, Resistance, Current, Continuity, Diode measurement● Can measure Resistance up to 200.0 Mohm● Checks a wide range of 3-phase power sources (80~750VAC)● Phase Rotation indication : clockwise and counter-clockwise on LCD● The LCD will show AC voltage between phases and Phase Rotation● Wide range for capacitance test: 0~40000μF(40.00mF)● REL / Auto-Zero function● MAX /MIN function● VAHz function● Frequency : 40.00 MHz● Data hold function● Over range indication● Low battery detection● Auto power off in 15 minutes● Convenient stand for viewing● Comply with EN 61010-1, CAT III 600V for the range of 600V AC/DC

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Transformer Oil Tester

    GTD-81 - Kingrun Instrument Co., Ltd.

    GTD-81 Insulation Oil Dissipation Factor and Resistivity Measuring System DTL, is designed and manufactured based on international standards. It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Programmable Wide Frequency AC Power

    PWF series - Preen AC Power Corp.

    The PWF series is a family of programmable AC power source with wide range of adjustable frequency, developed for aerospace or military’s 400Hz and 800Hz test applications, such as lab use, compliance test, and quality assurance. The PWF series consists of L series and M series, which have different output frequency range. L series provides 45~500Hz and 0~300V output, and M series provides 300~800Hz and 0-150V output. Users can select communication interfaces of RS-485, RS-232, and optional GPIB. The PWF series also have programming sequence functions of STEP and GRADUAL modes, three phase independent control, phase angle control, and disturbance function.

  • Electronic Ballast Automatic Test Equipment

    ATE-1 - Lisun Electronics Inc.

    Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • Power Line Meter

    Alpha Lab, Inc.

    The Line EMI Meter measures electromagnetic interference in a single-phase AC power line. It plugs into a wall outlet (mains socket) and requires no battery. It immediately displays total line noise in millivolts (range 1999 mV, resolution 1 mV) in the frequency range 10 KHz 10 MHz (the frequency limits at which sensitivity is of the maximum sensitivity). A speaker plays the sound of the EMI, amplitude demodulated, in order to identify the EMI source (such as an AM or shortwave radio station vs. a motor vs. an electric arc).

  • Single Channel USB Programmable Instrumentation Amplifier

    USBPIA-S1 - Alligator Technologies

    The USBPIA-S1 stand alone USB controllable module provides a single channel of high-quality instrumentation amplifier and optional AC coupling, for front-end signal conditioning compatible with all popular A/D converter devices. The USBPIA-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPIA-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPIA-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.