Showing results: 181 - 195 of 2477 items found.
-
NEO TELE-TRONIX PVT. LTD
We are highly reckoned among clients for manufacturing and exporting an excellent AC High Voltage Test Set. It is specially engineered and developed for performing varied tests on air conditioner. As to satisfy clients' requirements, we can also optimize this test set. Manufactured in accordance with industry standards using supreme grade raw materials, this AC High Voltage Test Set is offered to clients at industry leading price. Before the final dispatch in market, this test set is stringently tested on varied quality parameters.
-
DAC-6017 -
Soken Electric Co. Ltd
It can measure and diagnose the insulating characteristic of winding coils of high voltage electric motor, generator, and etc.It also makes possible to build in-vehicle type or stationary type in accordance with the application.
-
CIE / 5050A -
Cambridge Instruments & Engineering Co.
'CIE' A.C. High Voltage Breakdown Test Set is ideal for fast accurate & reliable testing of withstand/Breakdown test of electrical & electronic materials, components, equipments, panel boards, etc.
-
Series 60 & 65 -
Pickering Electronics
High voltage relays - chassis mounted, up to 15kV. Tungsten switches with power rating of 50 Watts maximum. Series 60 has solder terminals and nylon chassis mounting studs
-
22400 -
S & G Tool Aid Corp
Two circuit testers in one - troubleshoot both primary and secondary circuits. Use as a primary circuit tester on 6 and 12 volt circuits or on secondary or high voltage circuits to check out spark plugs. 48" lead wire.
-
HVSCM -
Test Electronics
Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.
-
WMA-005 And WMA-005LF -
Falco Systems
The Falco Systems WMA-005 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-005LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.
-
Supreme Instrument Laboratories
Supreme High voltage Oil Testing Apparatus is designed for testing of dielectric strength of transformer Oil or any other insulating liquids. It constitutes a complete equipment and apart of an A.C. supply of 230 / 240 Volts, no other supplementary facilities are required for its operation.
-
NEO TELE-TRONIX PVT. LTD
Hard-wearing and technically-sound High Voltage Test & Measurement System is developed to provide accurate results. These systems are widely used in power, electrical, engineering and other industries. They are designed using heavy-duty spare-parts to add strength with life to the systems. They are ideal to provide accurate results without any flaw to ensure to provide the best performance. These systems are perfect combination of easy usage, durability and high accuracy in results.
-
40-320A-101 -
Pickering Interfaces Ltd.
The 40-320A-101 is a single 24-channel MUX and is part of our 40-310/320A range of High Voltage Switching Modules which will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320A) configurations.
-
40-320A-001 -
Pickering Interfaces Ltd.
The 40-320A-001 is a single 12-channel MUX and is part of our 40-310/320A range of High Voltage Switching Modules which will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320A) configurations.
-
P150 -
FLC Electronics Inc
The P150 is a general purpose linear amplifier having a fixed amplification of 20 times and capable of unipolar high voltage output of +150V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to +10 V can be used as an input device. The amplification can be set to x15 (or other value) on request.
-
Analog Devices Inc.
Analog Devices’ offering of digital-to-analog converters with on-chip high voltage output amplifiers includes the AD5501/AD5504, which are single-channel/quad-channel products with a DAC output range of 0 V to 30 V or 0 V to 60 V. The AD5535 is a 32-channel DAC with output range of 0 V to 50 V or 0 V to 200 V.
-
GTU-250KVA/500KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
Accel-RF Corporation
The advanced development of new technologies, such as SiC and GaN, have opened the opportunity for more efficient and higher voltage/power performance in switching and power management circuits. Their high cutoff frequencies, low on-state resistance, and very high breakdown voltages can increase power supply power handling densities approaching hundreds of watts/inch. Reliability of these new technologies and techniques is critical for realizing practical applications. While Silicon devices have a rich history of proven reliability, these newer compound semiconductor technologies are too new to have a reliability history and have not been well proven. Further, process variations, even in well-controlled lines, yield widely varying results. This has driven the need for additional testing and to burn-in devices prior to delivery.