Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1996 - 2010 of 2471 items found.

  • TEV Antenna

    Techimp HQ S.r.L

    TEV sensor is a partial discharge sensor whose working principle is based on a direct Capacitive coupling with a Switchgears earthed metal case. The two ends of TEV sensor can be coupled magnetically to virtually any opening on a metal Surface. It picks up the electric signal given by PD activity onto the two metallic surfaces. Thanks to its special design has high sensitivity, larger than other single ended TEV sensors. His compact and robust design (passive sensor) makes the TEV the optimal sensor for direct installation on medium voltage Switchgears.

  • 1U Rack Adapter for Series HSF-1U, HSF-1UR

    RA 19 - Kepco, Inc.

    The 1U high rack adapter will mount four of the low profile 50W, 100W and 150W (Series HSF-1UR or HSF-1U) power supplies. Each plug-in power supply is equipped with a power on/off, indicator LEDs and voltage test points. The RA 19-1U provides access to the DIP switches and rack keying without disassembling the rack. It also provides a redundant scheme with modules 1 and 3 being powered from one a-c input and modules 2 and 4 from a second a-c input. Module numbering is left to right facing the front panel.

  • Cable Detectors

    PCE Instruments

    With certain models of cable detectors you can locate open power cables, either live or dead (without current), with voltages up to 300V. Cable detectors can locate cables, circuits, short circuits and ground points. To perform these functions, it is not necessary to disconnect electrically sensitive devices or to disconnect theCable Detectors to locate open power cables, either live or without current, up to 300V power from the cable which is being tested. Cable detectors can also locate ferrous and non-ferrous metals, wood and plastic with a high level of accuracy.

  • Power Supplies

    ZP-380B - CoolMax Technology Inc.

    Many power supplies fail to obtain the 80-Plus certification, which indicates that the power supply can provide 80% plus power efficiency. The ZP series, however, can. It is one of the few power supplies that can give you the power you need at higher efficiency, which means you can use the same power with less energy. It is also built with a 120mm fan that maximizes its cooling system and Active PFC to improve the stability and efficiency of the transmission network. APFC will help reduce transmission loss and improves voltage regulation. Save money at high power efficiency with ZP.

  • Power Supplies

    ZP - SERIES - CoolMax Technology Inc.

    Many power supplies fail to obtain the 80-Plus certification, which indicates that the power supply can provide 80% plus power efficiency. The ZP series, however, can. It is one of the few power supplies that can give you the power you need at higher efficiency, which means you can use the same power with less energy. It is also built with a 120mm fan that maximizes its cooling system and Active PFC to improve the stability and efficiency of the transmission network. APFC will help reduce transmission loss and improves voltage regulation. Save money at high power efficiency with ZP.

  • 48-Channel High Performance Strain Gauge Measurement Instrument

    EX1629 - AMETEK VTI Instruments

    48-Channel High Performance Strain Gauge Measurement InstrumentSupports quarter-bridge (120, 350Ω or user defined), half-bridge or full-bridge24-bit ADCs, sampling rates up to 25 kSa/sBuilt in programmable differential excitation -8V to 8VBuilt in selectable bridge completionConfigure signal conditioning excitation and bridge completion on a per channel basisSimple, low-cost wiring using RJ-45 telecom connectorsSupports TEDS for easy transducer detection and setupRJ-45 input connector reduces setup cost and timeBuilt in self-calibration and shunt calibrationSupports voltage, ratiometric and linear measurements other than strain measurements.

  • X-Ray Inspection System

    MX1 - Manncorp

    Manncorp’s new MX1 is a high-performance x-ray inspection system designed for real time imaging of multilayer PCBs and dense metal BGAs, μBGAs, and chip scale packages. Its high voltage (80kV), computer-controlled x-ray tube and 35 μm focal spot provide the power necessary for detection of a variety of defects including bridging, voids, and missing balls. The MX1’s standard camera features continuous zoom magnification from 4X to 50X and variable angle viewing up to 45°, and an upgrade to the x-ray tube can boost magnification to 225X.

  • Solid State Relay

    5200 - AMETEK Drexelbrook

    The B/W 5200 Series solid state relays are offered in two basic types for use in a wide range of low and high sensitivity applications.Both 5200 solid state relays are designed to operate on either 115 or 230 volts AC at 50/60 hertz.Both models incorporate a low voltage sensing circuit.Furhtermore, both solid state relays are capable of performing control functions directly from electrodes suspended in a well or tank, the B/W Unifloat level sensing system, or various pilot devices such as pressure, flow and limit switches, thermostats and push buttons.

  • TE-Metrology

    HIGHVOLT Prüftechnik Dresden GmbH

    The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components

  • LED Power Supply

    Shanghai Yiya Electronic Instrument Co., Ltd.

    1. High efficiency, low temp. movement(<18℃ in full load, superior stability. 2. Power supplies can be used in dry,damp and wet locations. 3. Built-in EMI filter & low ripple, reduce LED attenuation & increase life span. 4. Aluminum mental housing, easy for heat dissipation & ensure stability. 5. Automatic protection for over voltage, over current 6. 8-hour full load aging test, strict QC before delivery. 7. IP66/67 waterproof rating, suitable for outdoor & indoor application.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785996-01 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    779994-02 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9235, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785995-01 - NI

    10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9235 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9235 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • PCI I/O Module for Sound and Vibration

    JSV-4461-PCI - Jumho Electric Corporation

    2-channel ICP analog voltage inputMaximum sample rate: 204.8KS/s; simultaneous acquisitionAnalog-to-digital converter: delta-sigma, 24 bitsPhase Accuracy < 0.05deg@10KHzMaximum analysis bandwidth:96 KHzInput range from ± 42.4 V to ± 316 mV Coupled Mode: AC, DCDigital filter: user-defined low pass, high pass, band pass, band stopDynamic range: 118 dB; harmonic distortion: -107dB; channel crosstalk: -138dBICP current: 0-4 mA, optional 2-channel analog output range: ±10 V; update rate: 204.8 kS/s

  • Extra-Ground Current Impuision Equipment

    JYQ - Kingrun Instrument Co., Ltd.

    Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.

Get Help