Showing results: 61 - 75 of 1816 items found.
-
JX16/AB-1 -
Cytec Corp.
This module has 16 single pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.
-
JX16/AB-2 -
Cytec Corp.
This module has 16 two pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 two pole matrix. It is available with Type S, M or LT reed relays for high speed, long life application. These modules are usually used for 2 wire matrix applications where any number of 2 wire signals must be switched between either of 2 pieces of equipment.
-
GX6188 Series -
Marvin Test Solutions, Inc.
The GX6188 is a 6U PXI, high density matrix, GENASYS architecture switching card. The card provides the user with the ability to connect and interface resources to multiple UUT connections. The board consists of two matrices - a 104x8 and a 8x8 matrix. The GX6188 can connect to 104 UUT switching points, eight external resources and an eight channel global bus via front panel connectors. Multiple GX6188 cards can be connected using the global bus. Like other GENASYS switch cards, the GX6188 features an integral, 3-dimensional switching architecture which provides the flexibility to connect test system resources to multiple UUT connections as well as supporting an expansion bus connection without sacrificing I/O matrix connections when building multiple switch card configurations.
-
P9165A -
Keysight Technologies
P9165A 2x8 USB solid state switch matrix, 300 KHz to 6.5 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution in the form of compact USB controlled involving larger scale of multi-DUT or multiport measurements such as 5G massive MIMO antenna measurement and others.
-
P9164B -
Keysight Technologies
P9164B 2X16 USB solid state switch matrix, 300 KHz to 9 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution in the form of compact USB controlled involving larger scale of multi-DUT or multiport measurements such as 5G massive MIMO antenna measurement and others.
-
P9164A -
Keysight Technologies
P9164A 2X16 USB solid state switch matrix, 300 KHz to 6.5 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution in the form of compact USB controlled involving a larger scale of multi-DUT or multiport measurements such as 5G massive MIMO antenna measurement and others
-
P9165B -
Keysight Technologies
P9165B 2X8 USB solid state switch matrix, 300 KHz to 9 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution in the form of compact USB controlled involving larger scale of multi-DUT or multiport measurements such as 5G massive MIMO antenna measurement and others.
-
GLSUN-MEMS-8x8 -
Guilin GLsun Science and Tech Group Co., LTD
Fiber Configurations 8x8 ports Fiber Type SM, 9/125 umTest Wavelength 1530/1570 nm Operating Voltage 4.8~5.5VSwitch Type Non-latching Fiber Length 0.5m±5cmConnector LC/PC Tube Type 900 umOperating Temperature -10°C~ +70°C Storge Temperature -40°C ~ +85°C
-
CXG Matrix -
Cytec Corp.
These Chassis are built as 50 or 75 ohm matrix configurations of 4x8 or 8x8 using tree switch configuration switch modules for high bandpass. The internal matrix block is wired out to BNC, SMA or other 50 or 75 ohm connectors. LEDs on the front panel show switch and power status. Add a Control Module to complete the system.
-
40-565B-002-87X8 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.
-
40-565B-202-29X8 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.
-
40-565B-102-116X8 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.
-
40-565B-002-116X8 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence
-
40-565B-102-174X8 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.
-
40-565B-102-29X8 -
Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.