Showing results: 1321 - 1335 of 1816 items found.
-
40-561A-221-60X8 -
Pickering Interfaces Ltd.
The 40-561A-221-60X8 is part of a range of high-density PXI BRIC matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays.
-
40-561A-222-60X8 -
Pickering Interfaces Ltd.
The 40-561A-222-60x8 is part of a range of high-density PXI BRIC matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays.
-
40-562A-222-88X4 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-562A-222-66X8 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays.
-
40-562A-221-88X4 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays.
-
40-561A-221-90X8 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-561A-222-90X8 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-560A-221-92X8 -
Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-550-902 -
Pickering Interfaces Ltd.
This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.
-
40-558-401-96x16 -
Pickering Interfaces Ltd.
The 40-558-401-96x16 matrix is part of a range of BRIC ultra-high-density large PXI matrices are available in 2, 4, 8 or 12-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
40-592A-113 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
40-592A-104 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
40-595A-006 -
Pickering Interfaces Ltd.
The 40-595A is a matrix module based on the BRIC format that is designed for fault insertion applications in safety critical testing. As with other BRIC modules the matrix size can be scaled to suit the user application. The 40-595 has a very high current rating of 10 Amps, ideal for higher power systems, and can be used as a conventional matrix.
-
40-592A-112 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units.
-
40-595A-001 -
Pickering Interfaces Ltd.
The 40-595A is a matrix module based on the BRIC format that is designed for fault insertion applications in safety critical testing. As with other BRIC modules the matrix size can be scaled to suit the user application. The 40-595 has a very high current rating of 10 Amps, ideal for higher power systems, and can be used as a conventional matrix.