Showing results: 241 - 255 of 270 items found.
-
BAUR TDR 510 -
BAUR Prüf- und Messtechnik GmbH
Handheld Time Domain Reflectometer TDR 510. The BAUR handheld time domain reflectometer TDR 510 is used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables. The BAUR TDR 510 comes with a device storage for 50 measurements and the option to compare the trace of an active TDR measurement with a stored trace.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on live cables through the measurement category CAT IV / 600 V* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
Extech EX503 -
Extech Instruments Corporation
The EX503 offers an array of must-have multimeter measurements including capacitance, frequency (dual sensitivity for electrical and electronic applications), diode test and continuity. Other features include Data Hold and Relative Hold, and manual- or auto-ranging modes. The latter automatically adjusts the measurement range based on the detected source such as electrical components and electronic equipment. The meter features 0.5 percent accuracy and a CAT IV-600-volt safety rating, protecting users even on outdoor wiring. Includes EX503 heavy-duty digital multimeter, double-molded test leads, magnetic hanging strap, 9-volt battery, carrying case, and user manual.
-
Extech EX411A -
Extech Instruments Corporation
The EX411A offers multiple functions so you can carry one meter into the field instead of several. The manual-ranging EX411A measures AC/DC voltage, AC/DC current, resistance, diode, and continuity, all with +/-0.5 percent basic accuracy. The unit has low current capability, measuring down to 0.1uA, and features input fuse protection and mis-connection warnings. A Type K thermometer is built in for surface or air temperature measurements. Comes with CAT III test leads, stand, hanging strap, holster with built-in test lead storage, Type K bead wire temperature probe, and battery.
-
885 PR -
Standard Electric Works Co., Ltd
● 3 functions in one unit: Phase Rotation, Phase Presence, Voltmeter● LCD contact type Phase Rotation Tester● Large LCD to show phase rotation and phase presence● Check a wide range of three phase power sources● Voltage range for phase rotation test: 75~600V AC ● Frequency range: 40~400Hz● 6000-count voltmeter● Auto ranging Voltmeter AC/DC● Data hold function● Auto power off● Convenient stand for viewing● Easy to use● Comply with EN 61010-1 CAT III 600V EN 61010-2-033 EN 61326-1
-
8010 IN -
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1
-
ET4500 -
Martindale Electric Co. Ltd
The new ET4500 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
can be used to carry out 3 wire earth testing and has on board memory to store and download all installation test results for documentation.
Everything about the new ET Series has been designed to save time and make testing easier.Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .Supplied with a full range of accessories.
-
DSX CableAnalyzer™ Series -
Fluke Networks
The DSX CableAnalyzer Series copper test solution enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you'll be. Unfortunately, there are a lot of things that slow the process down setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.
-
T-BERD/MTS-5882 -
Viavi Solutions Inc.
The T-BERD/MTS-5882 is extremely versatile, enabling the cell site technician to address all key tests with one, lightweight, handheld tester; including: Fiber Inspection: Dirty fiber connections are the #1 cause of network downtime. Microwave back-haul: The majority of microwave backhaul links around the world are still microwave. Enhanced Cable Diagnostics: Environmental factors can damage the CAT X shielded twisted pair cable connecting the microwave antenna. Fronthaul: Avoid dangerous tower climbs with CPRI testing including BERT, PIM detection, MIMO diversity, RET, and VSWR. Backhaul: In addition to packet testing across error-prone microwave hops.
-
LDH400 Series -
Aim-TTi
Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option
-
Extech 380976-K -
Extech Instruments Corporation
The 380976-K is a Single Phase/3 Phase 1,000 Amp AC Power Clamp Meter Kit. Measures 1/3-Phase True Power (kW), Apparent Power (kVA), Reactive Power (kVAR), Horsepower (HP), Power Factor, and Phase Angle with Lead/Lag indicator. Auto Detect AC/DC Voltage measurements with simultaneous frequency display. In addition, the supplied test lead kit includes two CAT IV 72" test leads, 2 modular test probe handles, 2 plunger activated jaw clips, and 2 extra-large alligator clips. Complete with test lead kit, Type K probe, carrying case and 9V battery.
-
Extech EX840 -
Extech Instruments Corporation
This CAT IV True RMS clamp meter features a built-in IR thermometer with laser pointer for non-contact surface measurements from -58 to 518 °F (-50 to 270 °C). Clamp measures AC current up to 1000 Amp with a maximum resolution of 0.1 Amp. The 1.7-inch jaw fits around conductors up to 750MCM. Peak hold captures motor inrush currents and other surges. Data hold and auto power off functions. Other functions include AC/DC Voltage, resistance, Type K thermometer, capacitance and frequency. Complete with test leads, Type K temperature probe, 9 Volt battery and case.
-
781337-01 -
NI
16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module—The PXIe‑4300 provides integrated data acquisition and signal conditioning for high-voltage measurements. It provides increased accuracy, simultaneous sampling, and synchronization features for scalable measurement systems. The PXIe‑4300 includes 300 Vrms channel‑to‑channel CAT II isolation and 3,300 Vrms channel‑to‑earth 5 second withstand isolation to protect users and equipment from hazardous voltages. This module offers programmable lowpass filtering, DC input coupling, and two PFI lines for digital input triggering. The included NI‑DAQmx driver simplifies hardware and configuration and measurement.
-
LVD-415 -
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
4109 -
M. C. Miller Company
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
3000 MPR -
Standard Electric Works Co., Ltd
● 4000-count LCD● Auto ranging● Voltage, Resistance, Current, Continuity, Diode measurement● Can measure Resistance up to 200.0 Mohm● Checks a wide range of 3-phase power sources (80~750VAC)● Phase Rotation indication : clockwise and counter-clockwise on LCD● The LCD will show AC voltage between phases and Phase Rotation● Wide range for capacitance test: 0~40000μF(40.00mF)● REL / Auto-Zero function● MAX /MIN function● VAHz function● Frequency : 40.00 MHz● Data hold function● Over range indication● Low battery detection● Auto power off in 15 minutes● Convenient stand for viewing● Comply with EN 61010-1, CAT III 600V for the range of 600V AC/DC