DPT-12 -
Physitemp Instruments
DPT-12 Immersion Probe for Liquids - 12'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
DPT-24 -
Physitemp Instruments
DPT-24 Immersion Probe for Liquids - 24'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
Bio-Logic Science Instruments
Temperature range -35 °C to +150 °CTemperature accuracy ±0.3 °CComputer Interface USB 2.0Mains voltage 115 V/230 V 50/60 HzPower consumption 250 WDimension 400 x 313 x 385 mm (L x W x H)Weight 8 kg
-
NF Corp.
A/D converted input signals undergo discrete Fourier transform (DFT) to calculate complex impedance values and obtain parameters and characteristics specific to the DUT, such as its capacitance, inductance and quality factor. Original NF algorithms are also applied to allow equivalent circuits made up of R, L and C along with the constants for those circuits to be estimated from the complex impedance spectrum obtained by sweeping the frequencies.
-
DS-51 -
Ceibo Inc.
* Real-Time and Transparent In-Circuit Emulator * Supports Most of the 8051 Derivatives * Emulates 1.5V to 6V Microcontrollers * Maximum Frequency of 42MHz * 64K/512K of Internal Memory with Banking Support * 32K Trace Memory "on the Fly" * 64K Hardware and Conditional Breakpoints * MS-Windows and Keil ?Vision Debuggers * Source-Level Debugger for Assembler, PLM and C * On-Line Assembler and Disassembler * Performance Analyzer * Serially linked to IBM PC at 115 Kbaud
-
DS-XA -
Ceibo Inc.
* Emulates XA Derivatives * 2MByte Code and Data Memory * Memory With Mapping Capabilities * Real-Time Trace * Frequency Range up to 30MHz @ 5V * Source-Level Debugger For C And Assembler * MS-Windows Debugger Software for Windows NT and 95 or Later * 3.3V And 5V Emulation Support * Support for ROMless and ROM Microcontrollers * PLCC Emulation headers
-
DS-186 -
Ceibo Inc.
* Support for 80C186/8/XL/EA/EB/EC, 8086/8, V20/25/30/40/50 and other Microprocessors * Full-speed Emulation up to 25MHz * 1MB of Zero-Wait-State Mapped Memory * 8K x 32-bit Frames Dynamic Trace Buffer * 1MB Hardware Breakpoints * 115 KBaud RS-232 Communication Link * Numeric Coprocessor Support * OMF Converter * Support for Borland, Microsoft and Intel Compilers * Full Support for C, C++, Pascal and Assembler
-
-
I -
Memmert GmbH + Co.KG
In the laboratory, the Memmert incubator I is ideal for all applications with temperatures up to +80C specifically for incubating living cultures at +37 C. Thanks to the finely-tuned control technology, critical temperature overshoots are completely ruled out, valuable loads are therefore warmed up particularly carefully in this highly precise microbiological incubator.
-
PHHT15 -
Pyle Audio Inc.
Indoor Relative Humidty and Comfort Level IndicatorClock Display with Alarm FunctionSelectable Celsius or Fahrenheit DisplayTemperature Range: -50 to 70C / -58 to 158 FTemperature Accuracy: +/- 1 C (2 F)Humidity Accuracy: +/- 5%Humidity Display Resolution: 1%Sampling Period: 10SBattery: AAA, 1.5V (Included)Dimensions: 4.13' H x 3.94' W x 0.91' DWeight: 4.48 oz.Sold as : Unit
-
ENVIROMUX-GSM-IND -
Network Technologies Inc
Sends SMS messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. SIM card supporting SMS messaging required (not included). Ideal for harsh environments and high temperatures up to 149°F (65°C). GSM/GPRS/EDGE 850/900/1800/1900 MHz. AT command compatible. Dimensions: 3.58x2.28x0.87 in (91x58x22 mm). Operating temperature: -13 to 149°F (-25 to 65°C). Operating humidity: up to 95% non-condensing RH. Regulatory approvals: CE, C-Tick. Compatible with ENVIROMUX-SEMS-16(U).
-
Apogee Instruments, Inc.
Calibrated to a custom black-body cone with a measurement uncertainty of 0.2 C from -30 to 65 C when the sensor (detector) temperature is within 20 C of the surface (target) being measured. Radiometers are only sensitive from 8 to 14 m (atmospheric window) to minimize the influence of water vapor and CO2 on the measurement.
-
AOIP
The choice of infrared sensors, optical wavelengths and proposed in the range of infrared temperature measurement AOIP can meet a large number of fixed or mobile applications of noncontact temperature measurement from -40 C to 2000 C.
-
CHY firemate Co., Ltd.
Display: 3 1/2 digit liquid crystal display (LCD) with amaximum reading of 1999.Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: the " " is displayed when thebattery voltage drops below the operating level.Operating environment: 0°C to 50°C at<75% relativehumidity.Storage temperature: -20°C to 60°C, 0 to 80% R.H.withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% relativehumidity.Auto power off : 10 secondsDimensions: 148mm(H) x 105mm(W) x 42mm(D).
-
ThermoWorks
Easily measure surface temperatures with ThermoWorks non-contact IR guns, ideal for produce and agriculture inspectors, HVAC, construction, warehouse, quality assurance, HACCP and cold chain management, both shipping and receiving. Choose from fixed or adjustable emissivity; single, dual or circle laser types; and lens optics from close focus—for electronic components and laboratory measurements—to 100:1—for long distance measurements. High temperature ranges up to 3272°F (1800°C) are perfect for metallurgy and metal work foundries.