Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 204 items found.

  • Channelized Down-Converter

    DCV Series 5” x 2.5” x 0.6” - EM Research, Inc.

    *Connectorized Package *Wide Choice of Frequency Ranges *Integrated Filters *Gain Control *L-Band to 70 MHz IF Range Available *L-Band to 140 MHz IF Range Available *CAN, RS-232, I2C, or SPI Control *Internal / External References *Custom Designs Available *Low Power Consumption *Low Phase Noise *Low Spurs

  • Hydrophone

    RESON TC 4035 - Teledyne Marine RESON B.V.

    ​The TC4035 is a miniature probe hydrophone specifi cally designed as a standard reference hydrophone for sound measurements in the frequency range 100 to 500kHz. The hydrophone incorporates a 10dB low-noise preamplifier, which includes an insert calibration circuit for convenient electrical testing of the hydrophone condition. The pre-amp has a drive capability for cable length up to 25 meters.

  • Multifrequency Clock Synthesizer - PMC

    Model 7190 - Pentek, Inc.

    - Simultaneous synthesis of up to 5 different clocks- 8 SMC clock outputs- Ideal for A/D and D/A converter clock sources- Typical phase noise: -125 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 or 10 MHz- Four quad VCXOs allow selection from 16 different base frequencies- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 500 MHz- Control and status via PCI bus interface

  • Source Systems AC

    ZERA GmbH

    The power sources of MTS-series based on digital amplifier modules combined with frequency generator and reference device are the MTS source system. Single-phase systems (MTS1xx) or three-phase systems (MTS3xx) from 1 to more than 40 test positions are available.

  • PCM-FM Transmitter

    Model: DS-5220 - De Vries Scientific

    The S-Band PCM/FM Transmitter is a synthesized microwave signal source providing low phase noise with a high level signal output. The unit can be set to any frequency within the band of   design via a USB or RS-232/422/485 computer command. The oscillator is phase locked to an  internal TCXO  reference. The oscillator provides a stable low noise source for PCM data       transmission.

  • Video Transmitter

    Model: DS-5210 - De Vries Scientific

    The S-Band Video Transmitter is a synthesized microwave signal source providing low phase noise with a high level signal output.  The unit can be set to any frequency within the band of design via a USB or RS-232/422/485 computer command. The oscillator is phase locked to an internal TCXO  reference. The oscillator pro-vides a stable low noise source for video transmission.

  • Seismic Sensors & Transducers

    Riverhawk Company

    Displacement Pickups are vibration transducers that incorporate a spring-mass system with eddy-current damping using a frictionless pivot. This pivot is a spring flexure that serves as the ‘spring’ and a moment arm attached to the pivot serves as the ‘mass’, which allows resolutions down to the micro inch range. At frequencies above 50Hz, the mass remains fixed in space and becomes an inertial reference. A transducer within the pickup senses the motion of the mounting base relative to the inertial reference and converts it into a proportional signal. Appropriate damping results in a frequency response flat down to 10 Hz. Note that the pickup senses in only one plane, which is perpendicular to the mounting base.

  • Frequency Response Analyzers

    350C Series - Venable Instruments

    Venable Model 350c is the 3 channel successor to the original workhorse Model 350a/b that launched in 1986 and established Venable Instruments as a market leader. The contemporary 350c Series incorporates a 3rd channel, allowing the user to measure more transfer functions simultaneously with one sweep, such as source and load impedance. The 350c is the only frequency response analyzer in the industry that can measure absolute phase, using a reference channel.

  • Comb Generator, 10 MHz to 26.5 GHz

    U9391C - Keysight Technologies

    The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Comb Generator, 10 MHz to 50 GHz

    U9391F - Keysight Technologies

    The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Comb Generator, 10 MHz to 67 GHz

    U9391G - Keysight Technologies

    The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • 1207a Multi Channel Auto Switch

    Precise Time and Frequency, Inc.

    With intense competition and subscribers demanding ever more from service providers, quality and availability of service have never been more critical to maintaining and expanding your subscriber base.To complement our range of our high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new RF, Digital, and Time Code, Auto Switch / Distribution unit to insure you deliver the performance and reliability your customers demand.The ptf 1207A delivers up to eight channels of fully redundant, frequency and timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others, with NO SINGLE POINT OF FAILURE.The unit accepts two inputs on each channel from separate sources (primary and backup), monitors the inputs for signal integrity, and outputs the primary signal with no degradation of the input.If the primary input on any channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.The unit will accept up to eight channels simultaneously and independently switch on each channel.The unit also includes full remote monitoring and control via RS232 and Ethernet interfaces.

  • Ultra Low Noise, Rubidium Frequency Standard.

    A10-M - Quartzlock (UK) Ltd.

    Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.

  • Resonant Chopper Systems

    Electro-Optical Products Corp.

    An external clock signal, to provide an ultra stable modulating optical beam motion [sub] system. The system can be used as a "stand alone" unit, in the laboratory, or can be incorporated into a larger instrument/system. The chopper is ONE FIXED FREQUENCY, picked from the range of 5 Hz to 20 kHz. The chopper is a small size, light weigh, low cost and long life device. It requires low power drive electronics and does not radiate electromagnetic interference (EMI). It has high frequency stability and high amplitude stability. The chopper is IR, VIS and UV and high vacuum capable. Reference signal and position output available.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

Get Help