Showing results: 1 - 15 of 46 items found.
-
Signals & Systems India Private Limited
IRIG B Booster – SIB-1010 is used to boost the IRIG-B AM and PWM/TTL signal which is received from the GPS unit. It provides easy and affordable connectivity to substation equipment and power generation and distribution equipment. With this Plug-N-Play unit, you can expand your IRIG B connections to multiple devices instantly. It is rugged and surge-protected equipment. Its cabinet can be mounted directly on a wall, panel or DIN Rail, without the need for additional brackets. It has an inbuilt power supply module, therefore, doing away the need for an external power adapter.
-
-
RG1 -
North Atlantic Industries
The RG1 Time Code receiver synchronizes to IRIG-A/B/G time codes and provides precise time in a memory register, for the host SBC.The IRIG output of the card can be used to synchronize other IRIG time code readers. Additionally, the RG1 includes a real-time clock (RTC) that may be used as a reference source for IRIG master applications, to free the system processor from the task of updating the master timer.
-
Signals & Systems India Private Limited
IRIG B TO NTP/SNTP CONVERTER – SPC-INS-1010 is a compact DIN rail mountable protocol converter unit which synchronizes and maintains the timing and frequency requirement of power and process industry equipment using IRIG-B signal obtained from GPS receiver. It provides nanosecond accuracy when external time references are not available. It has the storage facility to store the system log file. It delivers NTP, SNTP, PFC-Pulse, RS232 & RS485 outputs. The system enables configuration and monitoring through Web-based application. It supports a wide range of power supply input either 90V-260V AC/DC or 18-36VDC or 36V-72VDC.
-
TCR180 -
Meinberg Funkuhren GmbH & Co. KG
The module TCR180 has been designed to receive and to generate IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements) or as an IRIG converter device. The frequency locking of the master oscillator to the time code system enables this module to generate fixed and programmable standard frequencies with high accuracy and stability. Various oscillator options allow the cost efficient implementation of different requirements concerning the accurracy of the outputs. The generator of the IMS-TCR module generates pulses per second and per minute and per hour. Four programmable outputs are also available. The pulses are synchronized to UTC-second.
-
TCR180PEX-EL -
Meinberg Funkuhren GmbH & Co. KG
The TCR180PEX-EL receives IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes and can be used for synchronizing the system time of its host PC. The IRIG output of this card can generate an IRIG signal for other IRIG time code readers. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements).
-
Precise Time and Frequency, Inc.
The ptf 1205A is a 12-channel IRIG amplitude modulated time code distribution amplifier housed in a 1U high, 19″ rack package. The ptf 1205A uses an RF design combining the latest technology in low noise components to minimize input/output delays which are of the order of nano seconds.The unit uses two stages of input signal buffering to distribute the input signal to 12 separate outputs, and insure maximum isolation between individual output signals.
-
TCR180PEX -
Meinberg Funkuhren GmbH & Co. KG
The TCR180PEX receives IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes and can be used for synchronizing the system time of its host PC. The IRIG output of this card can generate an IRIG signal for other IRIG time code readers. The output format is independent from the incoming IRIG signal - a perfect solution to your IRIG conversion requirements. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements) or as an IRIG converter device.
-
Avionics Interface Technologies — A Teradyne Company LOGIN Open Search Form F-SIM-1553-AVOE F-SIM-1553-AVOE -
Avionics Interface Technologies
Supports Capture, Recording, & Analysis of MIL-STD-1553 Chapter 10 Ethernet Data Streams - View Live MIL-STD-1553 Data and Activity Statistics from one or more Chapter 10 Streams - Compatible with AIT eDAQ-1553 & eDAQ-1553-FQ Modules - Open, View, Save, & Analyze MIL-STD-1553 bus data from Chapter 10 Archive Files - Replay MIL-STD-1553 bus data from Chapter 10 Archives using any of AIT’s MIL-STD-1553 Interface modules - Supported in AIT’s Flight Simulyzer simulation and analyzer software application
-
F-SIM-1553-CH10-STREAM -
Avionics Interface Technologies
Streams MIL-STD-1553 Data from AIT MIL-STD-1553 interfaces in Chapter 10 Format - Software application which is Compatible with all AIT MIL-STD-1553 Interfaces - Capable of streaming data captured from one or multiple MIL-STD-1553 Bus Interfaces - Streamed data can be sent to a single network system or multicast on the Ethernet LAN - Compatible with AIT F-SIM-1553-AVOE analyzer or 3rd party Chapter 10 systems - Timestamps & Errors detected embedded in Chapter 10 stream
-
AD14-500x4-IRIG -
Ultraview Corporation
The AD14-500x4-IRIG is a high performance wideband 4-channel 14-bit data single PCIe Gen3 board, that can continuously digitize four wideband signals, with four high linearity A/Ds. A second board version AD14-500x4-K7US-IRIG-B has all of the above features and can additionally be synchronized with stability of better than +/- 100 picoseconds with respect to an IRIG-B 1PPS signal and global time codes from a satellite receiver or local site time reference, allowing simultaneous synchronized acquisition of data at multiple locations anywhere in the world.
-
Dewesoft d.o.o.
Aerospace InterfacesDecode and visualize data from ARINC 429, MIL-STD-1553, IRIG CHAPTER 10, iNET and IRIG Chapter 4 PCM telemetry data interfaces.
-
CONW1553-1 -
Abaco Systems Inc
Transitions from a card end connector (with IRIG) on the QVME-1553 or QVXI-1553X into two 8" cables with CJ70 Twinax, 3 lug, 1553 cable jack ends, and four 8" cables with BNC cable jacks for I/O triggers and IRIG Rec/Gen.
-
PCIEX-SyncClock -
Brandywine Communications
The PCI-Express time code reference timing card with standard options such as IRIG B and optional GPS receiver provides an extremely accurate time source to the PCI-Express bus.
-
Brandywine Communications
Brandywine offers a wide range of high quality, state of the art signal timing distribution amplifiers, all with very low phase noise. These precision timing signal distribution amplifiers offer a variety of time and frequency signals and interface formats including IRIG A, IRIG B, Have Quick, 1PPS, as well as low phase noise reference frequencies. All of our distribution amplifiers feature dual inputs with automatic failover and multiple independently buffered outputs.