Filter Results By:
Products
Applications
Manufacturers
-
product
AR Radiated Immunity Test Systems
AR RF/Microwave Instrumentation
We have complete standard and custom test systems that perform entire radiated immunity tests with just the press of a few buttons. Everything you need – amplifiers, antennas, couplers, signal generators, system controllers, receivers, and more, along with the software to control it – all in one comprehensive system.
-
product
EMC Testing Services
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
product
RF Shielded Chamber
MIL-STD
A high performance RF-shielded chamber specifically designed for radiated emissions testing in accordance with MIL-STD-461E/F. This chamber can be used for conducted emissions, conducted immunity, radiated emissions, and radiated immunity testing.
-
product
TDK Software
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
product
EMC Testing Knowledge & Equipment
Creating, delivering, installing, and training on EMC test systems; RF Immunity systems, RF Radiated and Conducted Emissions systems, Conducted Immunity and Pre-compliant EMC systems.
-
product
Three Meter Fully Compliant Chambers
3 Meter Fully Compliant semi-anechoic chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations.
-
product
Technical Measurement & Consultation Services
Pulsed EMI, Emission, to radiated immunity testing. The highest level of testing and measurement technique and solution know-how are sure to be of service to you.
-
product
Pre-Scan Emissions/Immunity Chambers
3m pre-scan Immunity/Emissions semi-anechoic chambers are designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity and emissions measurements. When using this chamber for ANSI C63.4 pre-compliant radiated emissions pre-scan measurements there’s a limited scan height.
-
product
Solid State Pulsed Amplifiers
AR RF/Microwave Instrumentation
For automotive and military EMC radiated immunity susceptibility testing, as well as radar and communication applications, there is now a very attractive alternative to Traveling Wave Tube Amplifiers (TWTA’s).
-
product
Multi-Tone Test Systems
AR RF/Microwave Instrumentation
AR’s state-of-the-art multi-tone systems are designed to test RF Radiated and Conducted Immunity faster than ever before. Both the MT2IEC10V3M and MT4IEC10V3M fully comply with IEC 61000-4-3:2020 Edition 4, allowing for multiple tone testing, reducing test time by up to 74%. Commercial, aviation, and automotive industries, will perform RF radiated and conducted immunity testing faster, more accurately, more efficiently, and more closely to a real-world environment.
-
product
Test Cells (
LaplaCell
LaplaCells provide a facility for the rapid and efficient testing of the EMC compliance of products. These cells offer a calibrated and screened environment in which radiated emissions can be measured and immunity to RF radiation can be tested. They \re calibrated according to the methodology of IEC61000-4-20, thus affording compliant testing to IEC61000-4-3 and pre-compliance testing for radiated emission testing.
-
product
RF Synthesiser
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 230MHz for conducted tests and 30MHz - 6GHz for radiated tests. They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
-
product
Horn Antenna
TDK HRN-0118
The TDK HRN-0118 broadband horn antenna (1 GHz to 18 GHz) is designed specifically for radiated emissions and immunity measurements in EMC test environments. The HRN-0118 horn antenna provides optimal performance over the frequency range of 1 GHz to 18 GHz.
-
product
Fibre Optic Video Link
V-250
Fibre optic video links offer immunity to the effects of radiated interference, high voltage differentials, water, ground loops and the effects of hazardous environments. The systems offered here are fully compatible with B&W or colour NTSC, SECAM, PAL and D2MAC video standards.
-
product
Stripline Automotive 10KHz-30MHz 50 Ohm
STPL-30
The GTEMCELL STPL-30 Stripline is designed to produce high electric fields over a controlled bandwidth. It is used to perform EMC measurements according to automotive and aerospace standards in order totest the immunity of automotive and aircraft equipment to radiated electromagnetic fields.The STPL-30 uses a dual-sided tapered adjustable feed design into a tunable transmission line.
-
product
RF Amplifiers up to 1000 MHz
Narrow and Broad band high power RF modules and rack mount amplifier systems using solid state devices including LDMOS and GaAs in Class A and Class A/B topologies for Pulse, AM, FM, continuous wave and digital modulation applications that include EW, Radar, Jamming, EMI and EMC radiated immunity, and wireless communications testing.
-
product
TEM Cells
Transverse Electro Magnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz., EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.TEM cell generates a consistent electromagnetic field for testing small RF devices such as wireless pagers, receivers, portable phones, etc.
-
product
E-Series Average Power Sensor
E9304A
Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
product
Antenna, Octave Band Horn
EM-7021 | 2 GHz – 5 GHz
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
product
Antenna, Octave Band Horn
EM-7020 | 1 GHz – 2.5 GHz
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
product
Antenna, Octave Band Horn
EM-7022 | 4 GHz – 10 GHz
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
product
LETIS
Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.
-
product
ESD Protection
Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.
-
product
EMC Testing
Keystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing. EMC TestingKeystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing.Our EMC/EMI testing capabilities include but are not limited to:Radiated immunity testing up to 200 V/m from 10 kHz to 40 GHzRadiated emissions testing up to 40 GHzSurge testing to 10kV/10kA – and higherElectrostatic Discharge “ESD” testing up to 30 kVConducted immunity testing to levels well above the highest defined “standard” levelsMagnetic field immunity testing up to 100 A/m continuous and 1000 A/m short/impulseCustomized transient waveforms to extend level, duration and/or repetition of the standard’s definitionShielding Effectiveness from small panels and boxes all the way up to large enclosures and cabling, with a wide dynamic range all the way to 40 GHzWhat differentiates Keystone Compliance from other EMI test labs is our consultative engineering and expedited EMI test reports. Our staff understand EMC/EMI testing and has extensive experience with radiated immunity, radiated emissions, conducted immunity, conducted emissions, surge, ESD and shielding effectiveness testing. We also cater to specialized testing requirements. If you do not see the test standard or testing requirement you are looking for, please contact us as we may still be able to assist you.For more information about our scope of accreditation, please visit the links below.CISPR StandardsIEC/EN Product Family StandardsIEC/EN Test StandardsISO, SAE and Vehicle StandardsMilitary StandardsFCC, North American and International StandardsShielding Effectiveness TestingLightning and Surge Testing