Filter Results By:

Products

Applications

Manufacturers

Showing results: 181 - 195 of 277 items found.

  • 250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm

    PP019-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm

    PP022-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm

    PP020-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm

    PP023-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP024-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP025-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP026-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • Reach-In Solar Panel Test Chamber

    ACMAS Technologies Pvt. Ltd.

    For testing various size solar panels WIEBER designs and manufactures Solar Panel Test Chamber. The test are to be performed according to various standards of ASTM, IEC, UC etc. Solar panels need to pass environmental tests as per IEC and other standards requirements to prove their long term performance and resistance to temperature and humidity extremes. Solor Chamber also known as Solar Photovoltaic Testing Chamber and PV Module Test Chamber.

  • Temperature Controllers

    WIKA Alexander Wiegand SE & Co. KG

    The compact temperature controllers from WIKA offer display, control and monitoring of temperatures. The configuration of the sensor input is made via the multi-function input. Resistance thermometers, thermocouples and standard industrial signals, such as 4 ... 20 mA, serve as the input variable of a temperature controller. The monitoring output can be set either as relay (for slow control), as logic level for the control of electronic solid-state relays (for fast control and high current loads) or as a continuous 4 ... 20 mA output.

  • Thermocouples

    WIKA Alexander Wiegand SE & Co. KG

    Thermocouples are temperature sensors that generate a voltage directly dependent on temperature. Compared to resistance thermometers, they are particularly suited for high temperatures up to 1,700 °C. Instrument designs from mineral-insulated sheathed cable are very resistant against extremely high vibration loads (depending on instrument model, sensor element and wetted materials). The accuracy classes 1 and 2 apply for thermocouples in accordance with IEC 60584 as well as the standard and special classes in accordance with ASTM E230.

  • Furnaces

    Instron

    These three zone resistance wire wound furnaces are of split construction to facilitate fast and easy loading of a pre-assembled specimen train. The case is constructed from stainless steel with aluminium and hardened insulation board end plates. The optional front cut-out allows the use of side-entry high-temperature extensometry. Adjustable stainless steel latches keep the furnace halves locked together during use, but are then easily opened once testing is complete. The furnace is available with optional heavy duty brackets or mountings, which attach to a wide range of testing systems. An extensive range of standard controllers is available to suit most test regimes. Custom variants can be specified should the standard range not include a suitable unit.

  • Back and Forth Scratching Tester

    WGQ-60 - Shanghai Dean Electrical Co., Ltd

    Executive standard: NEMA、JIS; Inspection standard: JB/T4279.15-2008Used to detect the scraping resistance of coating and cable insulation layer of flat wires of 0.800~5.600mm (narrow side) and the silk and enamel covered round wires with nominal conductor diameter of 0.100~5.000mm;Application of SCM control allows for fast operation and strong anti-interference capacity;Sample support table allows for parallel rise and fall, maintaining close contact between the entire plane with sample;Scratching needle is vertical to the paint scraping direction and parallel with sample supporting table;When film is scratched and the action current is ≥5mA, painting scraper would automatically stop scraping;LED would automatically display the number of scraping.

  • Voltage Probe

    KHZ43201 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KHZ43201 voltage probe is a standard low resistance test probe, which meets the technical requirements for this product in the CISPR16-1 and CISPR14-1 test equipment. When measuring the interference voltage of the power grid, the artificial power supply network cannot be used at the load port, and sometimes it is necessary to use a voltage probe to measure the interference of the signal port, the load port, and the antenna port. The input impedance of the voltage probe to the ground wire is greater than 1.5KΩ, which can protect the input terminal of the receiver.

  • Igniter Testers

    AMPTEC RESEARCH

    Igniter Tester is a failsafe and portable digital ohmmeter specifically designed for ultra-safe resistance testing on squibs, flares, bridge-wire, and other explosive devices. The 620A-4 ohmmeter has been approved by the USAF Non-Nuclear Munitions Safety Board for usage on all non-nuclear munitions, and independently certified to meet Mil. Std. 810 Mtd. 511 for usage in fuel-filled environments. Due to its intense self-safety design and numerous certifications, the 620A-4 failsafe ohmmeter is the industry standard for military programs in need of igniter testing.

  • Omicron Fiber Optic Connector

    Teledyne Marine Impulse-PDM

    Teledyne Impulse-PDM’s Omicron 5030/5070 optical connectors utilize proven small form factor ferrule technology and are available for multi-mode or single-mode operation.The connectors are offered, as standard, in stainless steel to BSEN10088-3 Grade 1.4404 (316L), which is electro-polished to remove surface contamination, thus improving resistance to corrosion. Connector bodies can also be manufactured in other materials, either to address specific anti-corrosion requirements, or to increase depth rating. Engaging nuts are normally manufactured in naval brass to UNS C46400​.

Get Help