Filter Results By:

Products

Applications

Manufacturers

Showing results: 241 - 255 of 277 items found.

  • Test Leads

    AL-34WB - Standard Electric Works Co., Ltd

    ● Wire length: 1.2m approx.    Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm   Outside diameter of  PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit

    72-7770 CAL DU - Tenma

    The 72-7770 CAL DU from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.

  • Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit

    72-7770 CAL D - Tenma

    The 72-7770 CAL D from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.

  • Voltage/Continuity Testers

    VOT-53 - Standard Electric Works Co., Ltd

    ● 2000-count digital display (LCD type).    ● Test leads positioned at 19mm apart.● Interchangeable probe tip for 2mm and 4mm.● Polarity test ● Audible continuity test.● Auto sensing function for: voltage (AC/DC), Ω, diode.● Measurement function:   ACV/DCV: 1000V   Resistance: 2000Ω   Frequency: 30Hz~1kHz ● Phase rotation test : ● Waterproof design, protection class: IP65.● Phase / Neutral identification.● Rubberized double-molded housing.● Flashlight function.● Safety standard :     EN 61010-1 CAT III 1000V    EN 61010-1 CAT IV 600V    EN 61243-3    EN 61326-1

  • Multifunctional Safety Tests

    LXinstruments GmbH

    Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test

  • New Battery Analyzer

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • New Battery Conductance Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • New Car Alternator Charging Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • Electrical Safety Testers- Hipots

    Salicon Nano Technology

    Safety testers (also named hi-pot tester/hipot tester/hipot test) are designed to ensure safe operation of DUTs under various operating conditions and environment.GW Instek’s GPT-9900/GPT-9800/9600 series safety testers(hipot test) provide safe and quick measurement tools for AC/DC withstanding voltage tests, insulation resistance tests, and AC ground bond tests. Those tests are required by many international safety regulations such as CE, UL, VDE, and etc. We also have leakage current tester, GLC-9000, which supports all the major leakage current test standards for medical and general electronic equipment.

  • Power Line Purpose Tester

    LX-221A+ - Shenzhen Lian Xin Technology Co., Ltd.

    ·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.

  • External Measurement Instrument Port | Add-On Option to CableEye HVX Series Testers

    Item 835 - CAMI Research Inc. (CableEye®)

    Measure 10 GΩ Isolation at 100 V

    This new capability is of special interest to customers requiring measurements of extremely high isolation resistance at very low voltages. The HVX-series option may be ordered with new testers or added as an upgrade to previously purchased systems. Application Applications for such high isolation measurements at very low voltage include mission critical devices with densely packed pins that would arc at higher voltages potentially causing damage: For example, the testing of military or aerospace cables with nano connectors. Exacting Reporting Standards CableEye® software allows customers to meet the most exacting reporting requirements of government-contracted and ISO 9000-style certified companies. Co-Requisites This options co-requires the 4-Wire Kelvin Resistance Measurement option (Item 832), and a third party source Source Measure Unit (SMU – Keithley Model 2410 or 2470).

  • Insulation Meters

    PCE Instruments

    Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.

  • Installation Safety Testers

    PeakTech Prüf- und Messtechnik GmbH

    This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Battery Extra Load Units

    BXL Series - IBEKO Power AB

    BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.