Showing results: 406 - 420 of 1102 items found.
-
40-782A-521 -
Pickering Interfaces Ltd.
The 40-782A-521 is a single transfer switch and is part of our range of PXI microwave switching modules. It has a characteristic impedance of 50Ω and a maximum operating frequency of 18GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
J2190A -
PICOTEST Corp.
The J2190A active filter presents a high impedance (approximately 150kOhms) minimizing the loading of the circuit being tested. The output impedance is 50 Ohms allowing low noise coaxial connections to all typical test equipment. The 0.1Hz-10Hz noise band is common for opamp measurements, voltage regulators and voltage references. Many application notes offer schematics of such a filter for test purposes. An engineer’s time is much too valuable to be spent building test equipment. We have created a 4th order high pass and 4th order low pass filter with an optimally flat response and 0dB gain. Additional filters can be cascaded for even sharper cutoff.
-
Phillips Aerospace
Capabilities• VME, CPCI, VSX form factors• Differential pairs and controlled impedance• Matched length traces, trace guarding• Multilayer (designs to 26 layers completed)• Analog and designs (>6 GHz)• Column Grid Array, Micro-Ball Grid Array• Flex circuits
-
CP-3308R -
PINTEK Electronics
*100:1 scope probe *300MHz Bandwidth *Read out Function *Division Ratio x 100 *100MΩ Fix Input Impedance *1500V DC Working Voltage (CAT Ⅱ) *2000V AC peak to peak MAX. (CAT Ⅰ) *CE Approved.
-
Shanghai MCP Corp
Taut-Band movement.26 measuring range with Min. 1mV and 100uA(MS506-A) both in AC and DC.Zero at midpoint function (voltage meter,current meter and galvanometer 3 in 1).Overload warning LED indicator.Input impedance:100kΩ at all voltage ranges.Battery test function
-
Si9000e -
Polar Instruments Inc
With its fast, accurate, frequency-dependent transmission line modelling, the new Si9000e is designed to model transmission line loss, impedance at given frequencies and extract full transmission line parameters over a wide range of popular PCB transmission lines (over 90 structures).
-
EA163 -
eDAQ Pty Ltd.
This modular potentiostat is perfect for cyclic voltammetry and electroanalytical chemistry, and can use two (working and counter), or three (working, auxiliary and reference) electrodes. It can also operate as a galvanostat, ZRA (zero resistance ammeter), and high impedance voltmeter. It must be used together with any e-corder model.
-
1287A -
Ametek Scientific Instruments
The Solartron Analytical 1287A potentiostat and galvanostat is a high accuracy, wide bandwidth instrument which offers a range of DC test capabilities. The 1287A can be coupled with a frequency response analyzer, such as the Solartron Analytical 1260A or 1255B, and ZPLOT software for AC tests such as Electrochemical Impedance Spectroscopy.
-
HSL-DI32-DB-N -
ADLINK Technology Inc.
*Slave ID consumption: 2 - N: for 32-CH NPN sinking type sensor inputs or dry contact*Photo couple isolation voltage: 2500Vrms*Input impedance: 4.7KΩ*Input current: ??10mA (Max), ??12.5mA (Peak)*Input voltage: ??40V (Max)
-
Material Sensing & Instrumentation
Broadband Dielectric Spectroscopy is a powerful tool for investigating a variety of dielectric processes for both electrical and non-electrical applications. Also called Impedance Spectroscopy, the measurement separates molecular process on the basis of response time, providing a unique relaxation frequency along with a signature variation with frequency.
-
DU-1500T -
Array Solutions
The DU 1500T optimizes the performance of your antenna and transmitter or SWL receiver by providing adjustable impedance matching.The DU1500T also measures the Power and Standing Wave Ratio (SWR), which allows you to tune the indicted SWR to the lowestpossible ratio for the selected transmit frequency.
-
610102117 -
Virginia Panel Corporation
Primary mating contact 610102116. (May mate with other ITA contacts, as well.)20 GHz coax contacts have an impedance of 50 Ohms and a current rating of 5 amps.It is recommended to use SF142 to achieve 20 GHz and RG223 to achieve 12 GHz.
-
V965 -
CAEN S.p.A.
The Mod. V965 is a 1-unit wide VME 6U module housing 16 Charge-to-Digital Conversion channels with current integrating negative inputs (50 Ohm impedance). For each channel, the input charge is converted to a voltage level by a QAC (Charge to Amplitude Conversion) section.
-
V965A -
CAEN S.p.A.
The Mod. V965A is a 1-unit wide VME 6U module housing 8 Charge-to-Digital Conversion channels with current integrating negative inputs (50 Ohm impedance). For each channel, the input charge is converted to a voltage level by a QAC (Charge to Amplitude Conversion) section.
-
iP30z -
iPortable
The new iP30z iPortable™ Antenna SWR. Analyzer is designed for field use. This compact battery powered unit has an easy to read frequency display and measures SWR and impedance in the HF Band. The SWR readings quickly show you the actual VSWR measurement and Magnitude of the impedance (Z). This is the easiest way to adjust your portable or base station antenna to be best matched for your radio.