Showing results: 721 - 735 of 1102 items found.
-
42-724-021 -
Pickering Interfaces Ltd.
The 40-724-021 (PXI) and 42-724-021 (PXIe) are 32x8 RF matrix modules suitable for switching frequencies up to 300 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
E4982A -
Keysight Technologies
The E4982A LCR Meter provides the best performance for the passive component manufacturing such as SMD inductors and EMI filters, where impedance testing at high frequencies (1 MHz to 300 M/500 M/1 G/3 GHz) is required. Not only for the manufacturing, the E4982A can also be utilized for R&D, quality assurance with the powerful functions such as list measurements.
-
JY7003G -
Kingrun Instrument Co., Ltd.
JY7003G relay protection tester can verify various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronous, frequency, DC, intermediate, time, etc.) and microcomputer protection, and can simulate various complex instantaneous The whole set of tests shall be carried out for permanent, permanent and transformational faults.
-
TRZ -
ATCP Physical Engineering
The TRZ Horn Analyzer determines the operation frequency of the item to be tested and its impedance and current with the touch of a button. It’s quick and easy. With this quick and easily retrieved information, the user can perform the quality control of transducers, tuning of sonotrodes and ultrasonic horns, preventive and corrective maintenance of acoustic sets and much more (please, see the TRZ Applications).
-
Mors Smitt Group
All countries in the world have special regulations for testing and approvals of low voltage installations. In many countries these regulations are prescribing installers, inspectors etc. to check the electrical installation periodically. Prescribed tests that need to be performed are:RCD testInsulation resistance testEarth loop impedance testEarth loop resistance test (Rs-test)Earth resistance test
-
12XX Series -
Ametek Scientific Instruments
The 12xx Series Potentiostats has two current models: the 1287A and 1280Z. This family of potentiostats communicate through trusted GPIB interface technology that can convert to USB for easy connection modern computers. The Solartron Analytical 1287A and 1280Z are often driven by CorrWare software for DC testing, such as Cyclic Voltammetry, and ZPLOT for AC testing, such as Electrochemical Impedance Spectroscopy.
-
40-724-021-L -
Pickering Interfaces Ltd.
The 40-724-021-L (PXI) and 42-724-021-L (PXIe) are 32x8 RF matrix modules with y-axis loop-thru and are suitable for switching frequencies up to 150 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
40-724-011-L -
Pickering Interfaces Ltd.
The 40-724-011-L (PXI) and 42-724-011-L (PXIe) are 16x8 RF matrix modules with y-axis loop-thru and are suitable for switching frequencies up to 150 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
40-724-012-L -
Pickering Interfaces Ltd.
The 40-724-012-L (PXI) and 42-724-012-L (PXIe) are 16x4 RF matrix modules with y-axis loop-thru and are suitable for switching frequencies up to 150 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
40-724-022-L -
Pickering Interfaces Ltd.
The 40-724-022-L (PXI) and 42-724-022-L (PXIe) are 32x4 RF matrix modules with y-axis loop-thru and are suitable for switching frequencies up to 150 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
MIG0603CLV1 -
EMC Partner AG
The MIG0603CLV1 is a generator for testing varistors. It has circuits with three different source impedances and up to 11 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 200A which is maintained over the entire load range.
-
COMBI519 -
HT Italia Srl
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Teledyne LeCroy
Teledyne LeCroy has a wide variety of world class probes and amplifiers to complement its product line. From the ZS high impedance active probes to the WaveLink differential probing system which offers bandwidths up to 25 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
-
COMBI521 -
HT Italia Srl
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
EASYTEST -
HT Italia Srl
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.