Filter Results By:

Products

Applications

Manufacturers

Showing results: 856 - 870 of 1102 items found.

  • Polarity Indicator Circuit Tester

    CT8007 - General Technologies Corp.

    No ground wire means no wire tangles nor time lost searching for grounding points. High Impedance electronic circuitry. Negligible current draw ( 1 microampere) is 30,000 times less than regular lamp type testers. This gives complete safety when working around sensitive electronic control modules and sensors. Operating range between 6 and 28 Volt DC in battery powered systems

  • LCR-Reader-MPA: Ultimate All-in-One Digital Multimeter

    Siborg Systems Inc

    LCR-Reader-MPA combines tweezer probes with a powerful LCR/ESR-meter that is able to determine the type of component and best test parameters before measuring with a 0.1% basic accuracy. The device will display the main impedance value, any secondary values such as ESR, Q or D, component type and test parameters used instantly on a bright backlit LCD display. The 1 oz. device is very portable and ideal for fieldwork.

  • True RMS Digital Multimeter

    72-10415. - Tenma

    *Handheld digital multimeter*Measure AC/DC voltage, AC/DC current, resistance, frequency and capacitance*Diode test and continuity buzzer*Manual function select & auto ranging*Data hold function*Auto power off, low battery indication*Input impedance for DC voltage around 10Mohm*MAX / MIN / Relative Modes*Analog Bar Graph*CAT III 1000V, CAT IV 600V rated

  • Multifunction Electrical Installations Meter

    MPI-502 - Sonel S.A.

    Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling

  • Low Power Programmable AC Source with Transients

    61500 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61501)1500VA (61503)2000VA (61504)4000VA (61505)Voltage range: 0-150V/0-300V/AutoCompact size and weight attributable to advance PWM technologyAC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyLow output impedance for testing IEC 61000-3-2 (61505)Programmable output impedance for testing IEC 61000-3-3LIST, PULSE, STEP mode function for testing power line disturbance (PLD) simulation capabilityIEC 61000-4-11 voltage dips, short and variation simulationHarmonics, inter-harmonics waveform synthesizer for testing IEC 61000-4-13Programmable voltage, current limitComprehensive measurement capability, including current harmonicsHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientAnalog programmable interface3 units combined to 3-phase power outputEasy-use software for operation and IEC regulation testOptional GPIB and RS-232C interface

  • Active Probe

    Sonic - PMK Mess- und Kom­mu­nika­tion­stech­nik GmbH

    The Sonic® 4000 active probe offers best-in-class performance and is easy to use to make in-circuit measurements. The DC to >4GHz bandwidth, high input impedance, low noise and ±8V dynamic range make the Sonic 4000 the ideal probe for use with any oscilloscope or other 50Ω measurement system. The Sonic® 4000's ±12V input offset capability extends the probe's input voltage range.

  • Capaciter Tester

    KS-1600 - Konstar Electric Industrial Co., Ltd

    It is a dial instrument, and has the stable function and high reliability. It is driven by the battery. The instrument makes use of the indicator plate(102*79mm), thus displays clearly.This instrument can test the data of on-line capacitive resistance and on line impedance. It is an excellent instrument and an ideal tool for the people in labs, factory and household. When testing the mounted capacitor, it does net need to be completely out of power nor do the meter, and the meter can be testing continuously.

  • RS-485 and RS-422 Transceivers

    Analog Devices Inc.

    The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.

  • Circuit Synthesis Software

    Optenni Lab - Optenni Ltd

    Optenni Lab™ is the leading circuit synthesis software for antenna optimization aiming at efficient assessment and optimization of antenna systems at any design phase. Optenni Lab features automatic matching circuit synthesis and optimization, antenna array beamforming with active impedance control, and many supplementary assessment tools. Optenni Lab is often used in conjunction with EM simulators, and several links are provided with major EM tools on the market.

  • Ultra-low Noise Phase Inverter - Buffer

    WMA-IB-LN - Falco Systems

    The WMA-IB-LN can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision and ultra-low noise. The WMA-IB-LN model has been designed specifically for the Falco Systems WMA-200 high voltage amplifier. Two WMA-200 amplifiers combined with one WMA-IB-LN provide unprecedented noise performance and output voltage range.

  • Wireless

    Beltpacks - Trilogy Broadcast

    Available as either single or dual channel units, the Trilogy 410 Series beltpacks are designed for 4 wire operation providing a convenient portable connection to any Trilogy intercom system. Each is fitted with a momentary ‘push to talk switch’ plus individual volume control(s) for the incoming audio level. These high performance beltpacks are suited for use with any quality low impedance headset equipped with dynamic microphone depending on the model.

  • 100Hz-50kHz LCR Meter –

    11021/11021-L - Chroma Systems Solutions, Inc.

    The Chroma 11021/11021-L are the most cost-effective digital LCR Meters available, providing 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. The standard RS232 interface, optional GPIB & Handler interfaces, high speed and stable measurement capabilities enable the Chroma 11021/11021-L for use in both component evaluation on the production line and fundamental impedance testing for bench-top applications.

  • 100Hz-50kHz LCR Meter

    Chroma 11021/11021-L - Chroma Systems Solutions, Inc.

    The Chroma 11021/11021-L are the most cost-effective digital LCR Meters, providing 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. Standard RS232 interface, optional GPIB & Handler interface, high speed and stable measurement capabilities enable the Chroma 11021/11021-L can be used for both component evaluation on the production line and fundamental impedance testing for bench-top applications.

  • Predicting Microwave and RF Designs Virtually

    RF Module - COMSOL, Inc.

    The RF Module is used by designers of RF and microwave devices to design antennas, waveguides, filters, circuits, cavities, and metamaterials. By quickly and accurately simulating electromagnetic wave propagation and resonant behavior, engineers are able to compute electromagnetic field distributions, transmission, reflection, impedance, Q-factors, S-parameters, and power dissipation. Simulation offers you the benefits of lower cost combined with the ability to evaluate and predict physical effects that are not directly measurable in experiments.

  • GFCI and AC Circuit Analyzer

    Extech CT70-AC - Extech Instruments Corporation

    Circuit and wiring issues can introduce shock hazards (from grounding issues) and can compromise performance of machinery and equipment, from poor ground impedance, lack of sufficient voltage under load, and/or high ground-to-neutral voltage. The Extech CT70 is a GFCI and AC Circuit Analyzer which covers outlet load handling and outlet tester functions. Complete with an AC test cord (standard North American 3-prong plug).

Get Help