  • Time-Resolved Electrochemical Quartz Crystal Microbalance

    400C Series - CH Instruments, Inc.

    The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).

  • Powerful and Cost Effective Spectroscopic Ellipsometer

    Smart SE - HORIBA, Ltd.

    The Smart SE from HORIBA Scientific is a versatile spectroscopic ellipsometer for fast and accurate thin film measurements. It characterizes thin film thickness from a few Angstroms to 20µm, optical constants (n,k), and thin film structure properties (such as roughness, optical graded and anisotropic layers, etc).The spectral range from 450 to 1000nm is measured in a few seconds and ellipsometric data are analyzed using the DeltaPsi2 software platform. The software integrates two levels of software to fulfil both routine analysis with predefined recipes and advanced analysis with state-of-the art ellipsometric modelling.

  • Heat Flux Sensors

    MF Series - EKO Instruments Co., Ltd.

    EKO Heat Flow Sensors are applied to measure the heat flow or thermal conductivity in materials and radiative IR flux emitted by body surfaces. The sensors are suitable for indoors applications, some models made for outdoors purposes and are available in different sizes and thickness. All sensors are extremely flat, which is a big advantage considering the minimum interference with the conditions of the testing area the thermal dynamics. Since sensor foils are relatively flexible those can easy be applied on curved surfaces and can be used in different applications to measure the performance of insulating materials in refrigerators, container walls, pipes, building constructions, etc.

  • UPG-07 - Ultrasonic Precision Gages - Monochrome

    UPG-07 Monochrome - Danatronics Corporation

    PG-07 Series of hand held ultrasonic precision gages are available in 4 models. Our UPG-07 series is the ideal unit to non-destructively test the wall thickness for manufactured parts requiring unprecedented accuracy and resolution. The UPG-07 series utilizes single element transducers and offers a 30 Mhz, square wave pulser, .0001" or 1 micron resolution with the ability to store and re-call 30 unique applications. So if you are measuring light bulbs, plastic bottles, golf clubs, coil steel, thin aluminum, aircraft parts and even pure gold bars, the UPG-07 series is the right choice.

  • Manual Tablet Testing Units

    H-Series - Teledyne LABS

    The manual lab testers of the H-series in the new LAB.line design combine state-of-the art technology with usability: round shapes, generous radii and smooth surfaces allow for easy and hygienic cleaning.Operation of the embedded touch display is simple and intuitive: you can change a product or view informative test results with just a few clicks.The H series consists of three unit variations with usually 500 N, alternatively 50 N or 1000 N. The H5 version offers to connect an external scale (Sartorius/Mettler). With the H5+ version, you can even perform high-precision measurements with the external thickness gauge module.

  • Electrostatic Capacitance-Type Gap Detectors

    VE series - Ono Sokki

    VE series are non-contact type of vibration/small displacement detector with high accuracy which can measure the distance between conductor such as metal and sensor’s surface in micron/submicron resolution. It demonstrates its best performance when used for the measurement and control of the axial and surface vibration of rotational shafts such as main shaft of turbines, electric motors, compressors, and of the thickness and width of moving objects. In addition to the measurement of the amount of displacement, a gap detector can also be used for a wide range of other measurement and control applications such as the measurement of the amount of slack or warping. The non-contact measurement process enables to apply no load to rotational or vibration body, and does not affect the material under measurement.

  • Oven Data Logger

    215 - Elcometer Limited

    Memory stores up to 260,000 readingsIdeal for testing for powder or liquid coatings in batch or conveyor ovensVariable measurement interval, date, time, °C / °FHigh temperature resistant teflon coated probe cables are easy to clean after each runQuick display shows maximum temperature, Cure-Index figure and pass/fail for each probeMeasure up to 6 different temperatures at one timeIdeal in situations where powder coated thickness is inconsistentStart and stop logging at a pre-set temperatureLarge menu-driven display for easy operationPrint full colour report directly to any HP printerUSB data output to ElcoMaster® software and combine with other key inspection measurements

  • Syscal Pro

    IRIS Instruments

    The Syscal Pro is an all-in-one multinode resistivity and induce polarization sounding and profiling system for environmental and engineering geophysical studies. The Syscal Pro gathers a 10 channels receiver and a 250 W internal transmitter which make it the more powerful system of the Syscal range. Compact, easy-to-use and field proof, the Syscal Pro measures both resistivity and chargeability. It is ideal for environmental and civil engineering applications such as depth-to-rock determination, weathered bedrock mapping. With a maximal output voltage of 2000Vpp, the Syscal Pro is very adapted to detect deep fault in fractured aquifers or to characterize the depths and thickness of the groundwater aquifers.

  • Shielding Effectiveness Test

    Keystone Compliance

    Shielding effectiveness testing determines the ability of material to reduce the electromagnetic field in a space by blocking the field with barriers made of conductive and/or magnetic materials. Shielding effectiveness testing can be applied to a broad range of radio frequencies. Electromagnetic Shielding is typically applied to both enclosures and cables. The shielding can reduce the coupling or radio waves, electromagnetic fields and electrostatic fields. The amount of reduction can vary based on the material used, its thickness, the size of the shielded volume and the frequency of the fields of interest. Also impacting the effectiveness of the shielding is the size, shape and orientation or apertures in a shield to an incident electromagnetic field. Electromagnetic shielding that blocks radio frequency electromagnetic radiation is also known as RF Shielding.

  • Automated Live Fish Measuring System

    ViTec Co. Ltd

    The system for measuring and identifying aquatic organisms is designed to measure the linear dimensions and volume of live fish on a conveyor. The conveyor speed can reach 2.5 m / s, that is, up to 5 fish can pass through the installation in one second.The measurement of the thickness and volume of fish is carried out using a specialized camera Sick Ranger D40, which works on the principle of laser triangulation.The camera operation is synchronized with the conveyor movement using the Sick DGS-60 encoder.The industrial color camera Basler Scout scA1300-32gc is used for measuring the linear dimensions of fish (length and width), as well as highlighting characteristic features of different types (color of scales and fins) and possible defects.

  • Ignition Pulse Detector

    IP-3000A - Ono Sokki

    IP-3000A Ignition pulse detector is a slim and light weighted detector by using amorphous metals fiber element. It is 1/4 in thickness (mass: approx. 1/50) and 1/3 in weight compared with the previous model of Ono Sokki. Also the IP-3000A can obtain constant output from low to high rotation with high sensitivity.Meeting the needs of structure or mechanism in recent gasoline engines, the IP-3000A can easily clamp around an ignition coil cable (the primary side cord of ignition coil or the current cord of electronic distributor). Moreover, heat-resistant design up to maximum operating temperature of +120 C° enables measurement under harsh environment.The IP-3000A Ignition pulse detector can be used with Ono Sokki’s engine tachometer.

  • Materials And Chemical Analysis

    Anderson Materials Evaluation, Inc.

    Materials characterization, failure analysis, quality control, and materials and process development services are offered.  Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.

  • Resistivity Meter

    Model 2180 - Magnetic Instrumentation Inc.

    The unit is compact and lightweight. The basic system is 7″ wide by 2.5″ high and 12″ long. When measurements are needed below approximately 100 micro-ohm-centimeters, the basic system is piggybacked onto a second enclosure that houses a power amplifier with a current gain of ten. The combined unit measures 7″ wide by 5″ high and 12″ long. The combined unit weighs 11.5 pounds. Two short cables interconnect the two enclosures for powering the power amplifier and routing the signals to the fixture or four point probe. The front panel of the basic system includes a 32-character backlit LCD display and a set of function keys. An easy-to-use menu will allow access to user defined parameters such as sample thickness, sample volume, and calibration constants; upper and lower alarm limits, relative measurements, and several others.

  • Alcohol Tester

    Shenzhen Graigar Technology Co.,Ltd.

    Electrochemical (fuel cell) alcohol sensor, Module changeable Test Range: 0.000-2.000mg/l (0.400%B.A.C; 4.000%oB.A.C; 4.000g/l;) Alarming level: Pass level: 0.090mg/L (could be modified) Fail level:0.250mg/L (could be modified) Accuracy: +/-10% Work temperature: -10oC-50oC Work humidity: <95%RH (No Dews) Battery: 2XAA NiMH batteries, rating capacity: 2.1AH Dimension lXbXh: (mm) 250X105X400 Indication manner: mg/l,mg/100ml,g/l ,%BAC,%oBAC optional Coin for single time: 0-15 (For 0, the tester can be tested without coin). Coin diameter: 20mm-28mm Coin thickness: 1.2mm-2.5mm Coins Capacity: about 200 pieces Straw capacity: 200pcs(⊄<=7mm) Breath sampling time: about 5 seconds continuous breath.

  • Dielectric Breakdown Voltage and Dielectric Strength

    ASTM D149 - National Technical Systems

    This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem. This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used. It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium. This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test. This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method ASTM D3151). This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial. Note: The above information is taken directly from the test method Scope published in ASTM D149.