Showing results: 916 - 930 of 1121 items found.
-
CS2-CT -
Chuan Sheng Electronics Co., Ltd.
The CS2-CT provides high speed and multifunction, counting, control and communication (Modbus RTU mode) of Pulse from flow meter or encoder, proximity switch, photo switch for length control.There are 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue,and RS485 port available. They are also support N, R, C mode for totalizer control.
-
Hilkar
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
Maschinenbau Haldenwang GmbH & Co. KG.
Online appointment bookingfast, comprehensive vehicle inspection with transparent display of measurement resultsmenu-driven, automatic service process -> close dialogue between the customer and service employeesclearly defined order if the customer leaves the dealershipAvailability of all relevant data in one system (car legend) -> optimum customer approach by the present data and evaluationsregular flow of information about new features / changes in the dealership and on / for the vehicle
-
Ultrasonic -
Bacharach, Inc.
Bacharach's ultrasonic-based leak detectors support a variety of applications, including: Combustible and Refrigerant Gases, Compressed Air and Pneumatic Systems, Inert Gases (CO2, Nitrogen, Helium, etc.), Steam Trap Leak Detection, Condensate Flow, Thermal Expansion Valves (TXV), Solenoids, Mechanical Problems (Bearings, Wear), Electrical Arcing, Sealed Enclosures, Tanks, and Rooms, and Condition-Based Monitoring:
-
EAC-4Q-GS -
ET System Electronic GmbH
*Single system from 30kVA to 500kVA and in parallel up to 2MVA and more*Galvanic isolation from the network*TFT touch display with simple menu navigation*Emergency stop in the front door*Indicator lights for operating status*Bidirectional current flow, up to 100% of the nominal output power can be fed back into the grid*Output voltage and phase angle adjustable per phase
-
Texas Instruments
Ultrasonic sensing is the measurement of the time between an ultrasonic signal being sent and received. The interval between these two signals is typically referred to as time-of-flight (ToF) and depends on the distance the ultrasonic wave travels until it is reflected due to an impedance change and the speed of the ultrasonic wave. The basic equation time = distance / speed can be used to measure fluid level, fluid identification/concentration, flow, or proximity.
-
Wewon Environmental Chambers Co, Ltd.
Water pump for rain test chambers uses highly pressure stainless steel pump, ensure water pressure and flow of the test cycle, the pump is installed in the side of the IP test device, and both ends of the inlet and outlet to set up the joint, easy to replace and repair. Water tank can be disassembled,The corresponding joint or hose connection is arranged in the water pipe connection.
-
Shanghai Guantu Technology Co., Ltd.
The arrester is usually connected between the live wire and the ground, and is connected in parallel with the protected equipment. When the overvoltage value reaches the specified operating voltage, the arrester will act immediately, flow the charge, limit the overvoltage amplitude, and protect the insulation of the equipment; when the voltage value is normal, the arrester will quickly return to its original state to ensure the normal power supply of the system.
-
ADLINK Technology Inc.
ADLINK remote IO and serial communication cards are suitable for handling multiple digital signal types for IoT and other industrial applications such as facility monitoring, environmental monitoring, and industrial process control.Remote IO - NuDAM modules provide direct communication with various sensors, including performing signal conditioning, scaling, linearization and conversion to obtain temperature, pressure, flow, voltage, and current measurements. The new ND6100 series modules use Modbus/RTU remote data transmission protocols, providing customers with a comprehensive product portfolio. ADLINK's serial communication cards provide a PCI/PCIe interface and support RS-232 and CAN communication interfaces, allowing customers to choose the most suitable communication card for various automation equipment needs.
-
GeoPyc 1365 -
Micromeritis
The GeoPyc employs a unique displacement measurement technique that uses Dry Flo, a quasi-fluid composed of small, rigid spheres having a high degree of flow-ability. The sample is placed in a bed of Dry Flo which is agitated and gently consolidated about the sample. The GeoPyc collects the displacement data, performs the calculations, and displays or prints the results. The GeoPyc automatically determines the volume and density of a solid object by displacement of Dry Flo, a solid medium. The medium is a narrow distribution of small, rigid spheres that have a high degree of flow ability and achieve close packing around the object under investigation. The particles are sufficiently small that during consolidation they conform closely to the surface of the object, yet do not invade pore space.
-
ACCQPrep HP150 -
Teledyne LABS
Compared to Flash chromatography, High-Performance Liquid Chromatography (HPLC) operates under a higher pressure and uses columns of a smaller particle size for higher efficiency and increased resolution for purer results.HPLC is divided into analytical and preparative forms. Prep HPLC uses larger particles, meaning less surface area for the stationary phase, a higher flow rate and, generally, less pressure than analytical HPLC. Flash and prep HPLC are both used to purify large sample quantities; in analytical HPLC, the goal is to achieve the highest resolution possible to observe each unique compound in the sample. Explore the ACCQPrep® HP150 from Teledyne LABS to discover why ISCO is known worldwide for Prep HPLC.
-
Ajinkya Electronic Systems
IM2100 Series Scanners are useful for scanning parameters like temperature, flow, humidity, pressure etc and indicate them in a multiplexed manner. These scanners show the values one after the other in preprogrammed time interval called scan time. Options like PC communication, alarm relays are available. Scanners can communicate with SCADA software and are suitable for Data Acquisition system where local recording is not required.
-
LS-4B -
Hong Kong Songyang Industrial Ltd.
The water meter test bench is made up the platform, clamps, back and front pipe, flow counter group, standard measuring instrument and the outlet valve.When the inlet is connected with the stable water source, the water will get to the standard measuring instrument through the straight pipe. Compare the value of the checked water meter with that of the standard measuring instrument, the valve error that the water meter reads will be acquired.
-
Testing Machines, Inc.
TMI has a wealth of knowledge in instrumentation covering a variety of industries. Our Global PM&C (Preventative Maintenance and Calibration) Group is capable of providing calibration services for most laboratory instruments including Tensile Strength, Thickness, Elmendorf Tear, COF (Coefficient of Friction), Smoothness, Porosity, Parker Print Surf, Contact Angle, Compression, Burst Strength, Melt Flow, Impact Strength (IZOD/Charpy).