  • Non Contact Temperature Sensors

    Tempsens Instrument Pvt. Ltd.

    Non Contact Type temperature measurement involves determining temperature of object surface without direct contact with the surface. Tempsens offers both single point and area inspection model devices which are infrared thermometers and infrared camera and industrial furnace monitoring camera.

  • Laser Type PM Sensor

    SN-GC - Panasonic Industrial Devices Sales Company of America

    Panasonic’s Laser Type Particulate Matter Sensor has a very small footprint of W37 x D37 x H12 mm, and can be used to detect a wide variety of particulate matter including but not limited to dust, fly ash, soot, smoke, aerosols, fumes, mists and condensing vapors, solid fuels, construction materials, cooking/smoking of plant matter, fireplaces and furnaces, house/forest fires, waste incineration and much more.

  • Mineral Insulated Cables

    Tempsens Instrument Pvt. Ltd.

    We have world-class manufacturing plant for producing wide range of Mineral insulated (MI Cable), metal-sheathed cable. The applications of MI Cable are many such as blast furnace, atomic research, nuclear reactors, Kilns and many more. We provide standard as well as custom-built cables as per the customer need/ application requirement. We have very flexible lines so always ready to meet the demand.

  • Spot Pyrometers

    Fluke Process Instruments

    Fluke Process Instruments spot pyrometers are designed to be flexible and easy-to-install; durable to withstand the most demanding harsh industrial environments; and visual so you can see and understand your process temperature data. Spot pyrometers are a type of fixed thermal sensor used for measuring a single point on high-temperature surfaces, often in large furnaces or kilns. These devices measure temperature from the thermal radiation emitted, also known as radiometry.

  • Hydrogen Analyzer

    H‑500 - ELTRA GmbH

    Determination of hydrogen using the heat extraction method is a special requirement for the characterization of steel, steel alloys, copper and other metals. ELTRA’s H-500 is designed for the rapid and accurate determination of hydrogen in these materials. The H-500 analyzer uses the heat extraction technique and is equipped with a resistance furnace with quartz tube. The temperature can be set up to 1000 °C in steps of 1 °C. The usual working range of the H-500 is about 900° to 1000° C.

  • Heat Technology

    Weiss Technik

    In the area of industrial heating technology, our experienced team develops, plans and produces reliable systems for almost every possible area of application. Our product portfolio includes a broad range of heating and drying cabinets, cleanroom dryers, hot-air sterilisers, infra-red and continuous furnaces, and innovative microwave technology too. Alongside our comprehensive selection of series products, we also focus on the implementation of customer-specific, process-integrated solutions.

  • Atomic Absorption Systems

    Agilent Technologies

    Agilent leads the industry with innovative atomic absorption (AA) instruments. The entry-level SpectrAA 55B is ideal for labs in remote locations, while the 240FS and 280FS AA systems achieve the productivity of sequential ICP with Agilent’s Fast Sequential technology. The 240Z and 280Z AA systems provide superior performance and accurate background correction with transverse Zeeman technology. Our AA Duo systems feature unique simultaneous operation of both the flame and graphite furnace.

  • Arc Infrared Carbon and Sulfur Analyzer

    CS-8620 - Wuxi Tianmu Instrument Technology Co., Ltd.

    Infrared carbon and sulfur analyzer is used together with high-speed automatic ignition furnace to quickly and accurately determines the mass fraction of carbon and sulfur in steel, iron, alloy, non-ferrous metals, cement, ore, catalyst and other materials. a high-tech product integrating light, electromechanical, computer and analytical technology. It has the advantages of wide measuring range, strong anti-interference ability, complete functions, simple operation, accurate and reliable analysis results, etc. It is the ideal for measuring Carbon and sulfur in many industries. Analytical equipment.

  • Differential Temperature Controller

    Ajinkya Electronic Systems

    Normal temperature controller acts on one single input and tries and maintain that temperature at a pre programmed constant level. A differential temperature controller as the name suggest, takes two temperature inputs and tries to maintain the difference between these two temperatures as constant. This is widely used in today’s innovation Solar Energy Systems to provide maximum operating efficiency and flexibility. It automatically maintains the difference e.g., In case of self powered solar box furnace or in case of a solar water collector. By automatically switching on a fan or a pump the temperatures can be equalized.

  • Advanced SCR Power Controller

    Thyro-PX Series - Advanced Energy

    50 years of experience are infused in the Thyro-PX®  series’ design and functionality. The SCR power controller is available in single-, dual-, and three-phase units, supports voltages from 690 V and 2900 A, and offers superior interface options. Integrate operating modes and parameters seamlessly with the 2.8-inch, LED Thyro-Touch display. And enable efficient system parameters, loading, and storage via an on-board SD-card. Thyro-PX power controller is ideally suited for your transformer and resistive loads for glass, metal, and ceramic manufacturing. It is optimal for heating elements in electric furnaces.

  • Pyroelectric and Thermal Testing

    Radiant Technologies, Inc.

    The optional Chamber Task measures the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled within a thermal chamber, on a hot chuck or in a furnace. From these measurements the Spontaneous Polarization Pr(q) and the Dielectric Constant er(q) are computed. These are then combined to determine the Electrical Displacement D(q) as a function of the temperature q.

  • Fluid Power Actuators

    Type K Damper Drives - Rotork plc

    The Type K Range offers rotary and linear pneumatic damper drives for utility power plants, refineries, powerhouse boilers, furnaces and process heaters that require precise combustion air and flue gas handling solutions. Type K damper drives have proven to increase boiler efficiency, reduce maintenance, lower fuel consumption and reduce harmful emissions.

  • Flash Diffusivity Analyzers

    DLF 2800 - TA Instruments

    The Discovery Laser Flash DLF 2800 is an advanced freestanding instrument for the measurement of thermal diffusivity and specific heat capacity of materials from room temperature to 2800°C. The distinctive design incorporates a proprietary laser, laser optics, detector, and furnace technologies, and along with the unique six-position sample carousel, ensures unprecedented measurement accuracy and sample throughput. With the ability to operate in a variety of atmospheric conditions, including inert gas or under vacuum, the DLF 2800 can characterize a wide variety of materials, including polymers, ceramics, carbons, graphite, composites, glasses, metals, and alloys.

  • Sulfur and Carbon Analysis by Combustion

    832 Series - Leco Corp.

    LECO’s 832 series will redefine the way you determine sulfur and carbon in a wide variety of organic materials. Using extensive customer feedback and innovative engineering, our latest instrumentation takes advantage of an on-board software platform powered by a touch-screen interface, increasing usability and operational control without using valuable bench space. A high-efficiency combustion furnace, improved IR cell design, and a robust, rugged design make the 832 a valuable resource for any laboratory needing fast and accurate analysis of sulfur and/or carbon in organic materials.

  • Temperature Standards

    ITS-90 - Fluke Calibration

    The defining instruments of the ITS-90 (International Temperature Scale of 1990) are Standard Platinum Resistance Thermometers (SPRTs) and ITS-90 fixed-point cells. SPRTs are calibrated in fixed-point cells to provide the highest possible temperature accuracy. Primary standards offered by Fluke Calibration include: long-stem SPRTs; capsule SPRTs; triple point of water cells; metal fixed-point cells; maintenance baths and maintenance furnaces for fixed-point cells; standard resistors.