Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 976 - 990 of 1031 items found.

  • Precision LCR Meter

    TH2827C - Changzhou Tonghui Electronic Co., Ltd.

    TH2827 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable Chinese and English operation interfaces. Integrated transformer test function  greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • 1 A DIGITAL MILIOHMMETER

    MO-2Ke - MEGABRAS srl

    The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.

  • Variable Frequency AC Resonant Test System

    HDXZ-162kVA/54kV - HD Power Test Equipment Co.ltd

    HDXZ-162kVA/54kV Variable Frequency AC Resonant Test System is applied for AC dielectric withstand test for electric equipment.The system is mainly composed of following parts:variable frequency control power supply,exciting transformer,reactor and capacitive divider.1. 10kV/300mm2 cable 3km AC withstand voltage test, capacitance ≤1.1265uF, test frequency 30-300Hz, test voltage 22kV, test time 5min.2. 35kV/300mm2 cable 1.5km AC withstand voltage test, capacitance ≤0.2917uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • TE-Metrology

    HIGHVOLT Prüftechnik Dresden GmbH

    The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components

  • High Resistance Neutral Grounding Devices

    Hilkar

    HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.

  • NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783107-01 - NI

    250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.

  • Enhanced SCR Power Controller

    Thyro-PX DC - Advanced Energy

    The Thyro-PX DC series shapes the future of the growing hydrogen and DC heating markets. The SCR power controller series takes advantage of the existing Thyro-PX controller card architecture and is available as three-phase units, supports up to 1800 amps DC Current, and offers superior interface options. Integrate operating modes and parameters seamlessly with the 2.8-inch, LED Thyro-Touch display and enable efficient system parameters, loading, and storage via an onboard SD-card. The Thyro-PX power controller is ideally suited for your transformer and resistive loads for glass, metal, and ceramic manufacturing. It is optimal for heating elements in electric furnaces.

  • DC High-Voltage Test Device

    PGK 80 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • DC High-Voltage Test Device

    PGK 50 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 50. The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • Partial Discharge Testing Equipment

    PD-Analyser - Scope T&M Pvt, Ltd.

    This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • 50Hz-100kHz LCR Meter

    Chroma 11022/11025 - Chroma Systems Solutions, Inc.

    The Chroma 11022 and 11025 LCR Meters are passive component testers that can give you the most cost effective alternative equivalent to the high priced meters. They are designed for the demanding applications in production test, incoming inspection, component design and evaluation. Programmable test signal level settings are from10mV to 1V in a step of 10mV, and the VM/IM signal level monitor functions allow you to evaluate your devices at the level you specify. Ten test frequencies of 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, and 100kHz, can be used to evaluate passive components and transformers/ LF coils.

  • Couplers, Repeaters, Bus Switches, Connectors, Cables & More

    Excalibur Systems, Inc.

    Accessories for the MIL-STD-1553 data bus are as much of an interface as the communication card. Therefore at Excalibur we provide a full line of accessories for the MIL-STD-1553 data bus that include, Box/Inline Couplers, Repeaters, Bus Switches, break out boxes, connectors, terminators, transformers and custom cable assemblies. Excalibur uses only premier quality parts from known manufacturers. We constantly test our products to meet our higher standards.If you have a need for an accessory product for your card and it is not listed please contact us to see if it is a product we should be supporting.

  • High Voltage System

    HV-2 - International Electro-Magnetics, Inc.

    *Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.

Get Help