Filter Results By:

Products

Applications

Manufacturers

Instruments

read precision values.

See Also: Instrument Cables, Modular Instruments, Instrumentation Amplifiers


Showing results: 3646 - 3660 of 5003 items found.

  • Fraction Collectors

    Foxy Series - Teledyne LABS

    Durability and reliability are built into all three of Teledyne LABS fraction collectors, the Foxy® R1, R2 and R2 High Flow. Designed for accuracy and speed, these fraction collectors represent state-of-the-art functionality and innovation. The Foxy R1 and R2 fraction collectors are liquid distribution instruments with the ability to divide the liquid into multiple collection vessels, switching vessels on time, drops, volume, peaks, or a combination of these parameters. Collection vessels can be test tubes, vials, mini-wells, bottles, or funnels. The touch screen display simplifies set-up for a variety of collection routines. ​​​

  • NI-6581, 100 MHz, 54 Single-Ended-Channel Digital I/O Adapter Module

    780565-01 - NI

    100 MHz, 54 Single-Ended-Channel Digital I/O Adapter Module for FlexRIO—The NI-6581 is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. You can use the NI-6581 to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581 can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.

  • Human Vibration Monitor

    HVM200 - Larson Davis, Inc.

    The HVM200 is a small rugged vibration meter with built in Wi-Fi that can be used to measure hand-arm, whole body and general vibration. It includes the metrics and frequency weightings needed to measure human vibration. This 3 channel meter meets the requirements of ISO 8041:2005 and it is designed to measure per ISO 2631-1, 2 & 5 and ISO 5349 in support of the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs) and the directive 2002/44/EC. This makes the HVM200 an ideal choice for an instrument used to demonstrate compliance with human vibration requirements and regulations worldwide.

  • Wireless Device Functional Test Reference Solution

    Keysight Technologies

    The Keysight S8890A Wireless Device Functional Test Reference Solution provides an automation environment which is both simple to use, yet comprehensive and powerful. Based on the Test Automation Platform www.keysight.com/find/TAP, S8890A provides optional instrument driver/plug-ins offering simplified logically grouped control steps. These steps can be sequenced, looped and swept to provide powerful individual test cases or comprehensive sequences. Each driver/plug-in is provided with extensive starter sample test cases which can be modified by Keysight or the end user the UE to be tested. Plug-in options:

  • Temperature Transmitters

    Rotronic Measurement Solutions

    A temperature transmitter is an electrical instrument that interfaces a temperature sensor (e.g. thermocouple, RTD, or thermistor) to a measurement or control device (e.g. PLC, DCS, PC, loop controller, data logger, display, recorder, etc.). Typically, temperature transmitters isolate, amplify, filter noise, linearize, and convert the input signal from the sensor then send (transmit) a standardized output signal to the control device. Common electrical output signals used in manufacturing plants are 4-20mA or 0-10V DC ranges. For example, 4mA could represent 0°C and 20mA means 100°C.

  • Transition Time Converters

    Keysight Technologies

    These converters have been designed to convert the transition times of instruments with fixed, fast transition times, to slower, fixed transition-times (150 ps, 250 ps, 500 ps, 1 ns, 2 ns); hence reducing the signal bandwidth. All transition-times are between 10% and 90% of amplitude.The design of these converters ensures very low signal reflection far beyond the 3 dB point. Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications. The converters are fitted with two SMA connectors, one male, one female.

  • 350 MHz Universal Frequency Counter/Timer, 12 digits/s, 100 ps

    53220A - Keysight Technologies

    Two 350 MHz input channels, plus optional third channel (6 GHz or 15 GHz)12 digits/second resolution, 100 p sec time interval resolution LXI-C/LAN, USB, GPIB Built-in math analysis and color, graphical display (trend and histogram)Optional: Lithium Ion Battery Bench Vue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.

  • Angle Position Indicator, High Accuracy

    8810A - North Atlantic Industries

    NAI's 8810A Angle Position Indicator (API) is a rack-mount or bench-top measurement instrument featuring front panel controls and input terminals. The use of an intelligent DSP design eliminates push buttons and allows all programming to be done either via an integrated touch-screen, front panel USB optical mouse interface, or with the multipurpose increment/setup knob. Improved flexibility is provided by two fully independent inputs that can be used to read two separate input signals simultaneously, or can be combined to measure multi-speed Synchros or Resolvers.Read more: http://www.naii.com/Angle-Position-Indicator-High-Accuracy/P196#ixzz3ztgONPA5

  • PMA Suite For The PSA/PSL-3000: 802.3at (30W) PSE's

    Sifos Technologies, Inc.

    *In-Depth System Testing of 802.3at and 802.3bt 2-Pair PSE's Using PSA-3000 or PSL-3000 instruments*Concurrently Analyze Up To 192 PSE Ports*Robust Emulation of Type-1, Type-2, and Type-3 (Class 4) PD's Including PoE LLDP*Assess PSE Power Administration Decisions*Assess PSE Power Management Behaviors*Static and Transient Reserve Capacity Analysis*Per-Port Variation and Uncertainty Analysis*Assess PSE Power Reliability Over Time*Colorful and Graphical Pop-Up Spreadsheet Reporting*Available to PSA-3000 and PSL-3000 as part of the Live PD Emulation license feature

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-01 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-02 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-04 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

  • PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device

    778758-01 - NI

    100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.

  • PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device

    778758-03 - NI

    100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.

  • PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device

    778758-02 - NI

    100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.

Get Help