Showing results: 1 - 15 of 95 items found.
-
KIT -
Altanova Group
The Line impedance kit is composed of two modules, STLG and STSG. The kit is meant to be used with STS 5000, STS 4000 and eKAM in order to perform Line Impedance test.
-
LISN -
Com-Power Corporation
LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.
-
-
TBOH01 -
TekBox Singapore Pte. Ltd.
The TBOH01 5H LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.
-
44LS1 -
North Atlantic Industries
NAI’s 44LS1 is a 100-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides 22.5 to 30 VDC at 100 Watts to all downstream DC/DC converters.
-
VPX56-3HU -
North Atlantic Industries
NAI's VPX56-3HU is a rugged, high-performance 500-Watt Output +28 VDC Input 3U VPX AC/DC Power Line Conditioner designed for aerospace, defense, and industrial markets. This off-the-shelf power supply plugs directly into a standard VPX conduction cooled chassis and protects downstream DC-DC converters from MIL-STD-704 transients, low-voltage conditions and power interruptions, providing up to 50 milliseconds of holdup time at up to 500-Watts. Continuous Background Built-In-Test (BIT) and I2C communication are included.
-
-
EMCTEST
The LISN (Line Impedance Stabilization Network) or AMNs (Artificial Mains Networks) is a device to create a known impedance on power lines of electrical equipment during electromagnetic interference testing. Frequency range: 150kHz a 30MHz
-
Schwarzbeck Mess Elektronik
In addition to EMI measurement with LISNs (Line Impedance Stabilisation Networks, Artificial Mains Networks), Probes are used for Terminal or Line voltage measurement.LISNs are required to feed the Equipment under Test (EuT) with mains power, to reduce external line interference, to offer the EuT a standardized impedance and to route the extracted r.-f. voltage to the EMI receiver.
-
BroadWave Technologies, Inc.
Impedance matching pads from BroadWave eliminate impedance discontinuity (mismatches) without introducing reflection to the circuit. Custom units are available in a variety of impedance and connector types from DC to 4 GHz. BroadWave Technologies impedance matching pads preserve signal integrity by matching virtually any transmission line.
-
Teledyne LeCroy
Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 1kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.
-
CITS880s -
Polar Instruments Inc
Finer geometries and thinner copper can present a challenge for fabricators measuring impedance on leading edge PCBs. The CITS880s answers that challenge with the introduction of Launch Point Extrapolation (LPE). LPE extrapolates the TDR response back to a point close to the start of the transmission line effectively allowing to users more accurately to measure the instantaneous or incident impedance of the line.
-
Si9000e -
Polar Instruments Inc
With its fast, accurate, frequency-dependent transmission line modelling, the new Si9000e is designed to model transmission line loss, impedance at given frequencies and extract full transmission line parameters over a wide range of popular PCB transmission lines (over 90 structures).
-
2126 NA -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Built-in earth tester.● Built-in loop/psc tester. 0.03-2000Ω (software ctrl).● Built-in voltmeter.● Built-in wiring checker.● One push button smart control.● Display L-N and L-E voltages. 50 to 280Vac (sine).● Display line path impedance. 0.01-2000Ω (software ctrl).● Display earth path impedance. 0.01-2000Ω (software ctrl).● Display neutral path impedance. 0.01-2000Ω (software ctrl).● Display psc line to neutral. 6kA@230Vac supply.● Display psc line to earth. 6kA@230Vac supply.● Re-scroll through previous results.● Bat. ok/low battery indicator.● Auto off function.● Color-coded test leads.● Rugged case.● Ultra low power consumption.