- Pickering Interfaces Ltd.
product
PXI 8x SPST High Voltage Reed Relays
40-310-001
The 40-310/320 range of high voltage switching modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
Automatic Insulation Oil Dielectric(breakdown) Test
HDIIJ-80
HD Power Test Equipment Co.ltd
Automatic Insulation Oil Dielectric(breakdown) Tester is used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool, electric manufacturer and etc. It adopts full auto digital microcomputer, which has the function of high accuracy, strong anti-interference ability and safe reliability
-
product
Insulation Tester
61-797
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty
-
product
Insulation Tester, 250/400/1000V
61-795
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty
-
product
Automatic Insulation Oil Tester
KVIO-80
KV Hipot Power Test Equipment Co.,Ltd
Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.
-
product
Hi-Pot Testing
The CableEye HVX System combines our M3U tester with a high voltage module to provide Hi-Pot testing of insulation resistance and dielectric breakdown up to 1500Vdc and 1000Vac.
-
product
Partial Discharge
Is a localized dielectric breakdown (DB) (which does not completely bridge the space between the two conductors) of a small portion of a solid or fluid electrical insulation (EI) system under high voltage (HV) stress.
-
product
DC Hipot Testers
DPC series
UDEYRAJ ELECTRICALS PRIVATE LIMITED
DPC series hipots are used for proof testing of high voltage equipment in power engineering. Routine testing of the insulation and leakage is a necessary requirement for electrical equipments. Other areas include: Cable breakdown testing, capacitor charging and general laboratory use.
-
product
Capacitance & Tan-Delta Test System
TD-1
By measuring the electrical properties such as capacitance and Tan-Delta regularly on periodical basis, it is possible to ensure the operational unexpected breakdown. Dissipation factor (Tan Delta) is one of the most powerful off-line nondestructive diagnostic tool to monitor the condition of solid insulation of various high voltage equipment.
-
product
DC High Voltage Break Down Tester
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
product
AC High Voltage Break Down Tester
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
product
DC Hipot Testers
DPW Series
UDEYRAJ ELECTRICALS PRIVATE LIMITED
These portable testers have been designed to be used in testing high voltage equipment in power engineering. Routine testing of the insulation and leakage is a necessary requirement for surge arresters, cable breakdown testing, capacitor charging and other laboratory use.
-
product
LXI High Voltage Matrix 2-pole 300x2
60-310-302
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
LXI High Voltage Matrix 2-pole 200x2
60-310-202
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
Offline Stator Core Testing
Iris Power EL CID Evolution
The EL CID Evolution provides offline testing of inter-laminar insulation breakdown within a stator core. The only alternative to the Iris Power EL CID Evolution test is the Ring Flux (full flux) test. The Ring Flux test requires large power supplies, considerable manpower, and expensive infrared viewing cameras.
-
product
Connector Block, 50-Pin D-Type, Female
40-965A-050-F
The 40-965A-050-F connector block provides a simple method of connecting to 50-Pin D-Type connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximise copper cross-sectional area and insulation properties. Connector blocks have higher losses than a cable connection and the breakdown voltage is controlled by clearances to the metal shell. The metal shell includes an internal insulation barrier under the carrier board.
-
product
25-Pin D-Type Male Connector Block
40-965-025-M
This connector block provides a simple method of connecting to 25-Pin D-Type connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximise copper cross-sectional area and insulation properties. Connector blocks have higher losses than a cable connection and the breakdown voltage is controlled by clearances to the metal shell. The metal shell includes an internal insulation barrier under the carrier board.
-
product
25-Pin D-Type Female Connector Block
40-965-025-F
This connector block provides a simple method of connecting to 25-Pin D-Type connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximize copper cross-sectional area and insulation properties. Connector blocks have higher losses than a cable connection and the breakdown voltage is controlled by clearances to the metal shell. The metal shell includes an internal insulation barrier under the carrier board.
-
product
Connector Block, 78-Pin D-Type, Female
40-965A-078-F
The 40-965A-078-F connector block provides a simple method of connecting to 78-Pin D-Type connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximize copper cross-sectional area and insulation properties. Connector blocks have higher losses than a cable connection and the breakdown voltage is controlled by clearances to the metal shell.
-
product
LXI High Voltage Matrix 2-Pole 100x2
60-310-102
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing. The 60-310 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.
-
product
PXI 16x SPST High Voltage Reed Relays
40-310-101
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
PXI 12 Channel High Voltage Multiplexer
40-320-001
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
PXI 24 Channel High Voltage Multiplexer
40-320-101
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
product
Gas Chromatograph for Analyzing
GC2010D
Chongqing Kailian Yongrun Industrial Co.,Ltd.
Transformer uses oil as coolant and insulator. Gases are formed within the transformer oil due to natural aging, faults from oxidation, vaporization, oil breakdown, electrolytic action or insulation decomposition. Because the transformer oil bathes each internal component, dissolved gases in the transformer oil contain lots of diagnostic information. Meanwhile, the transformer is very expensive to be replaced, so monitoring these gases is very important to know the current quality of transformer or even when the transformer should be removed from service before failure. Presence of each gas composition and its concentration indicates possible failure of transformer.
-
product
High Voltage Tester For Hair Dryer & Hair Straightner
Every electrical apparatus or machine consists of two distinct sections - one which carries the electricity, and other which is isolated (insulated) from the electric currents. The former may be called the `Live' side whiles the latter `Earth’ side. A person near about the apparatus or handling it can safely touch the Earth side, but not the live side, for obvious reasons. To ensure that the isolation of the two sections is effected properly, the apparatus is tested by subjecting it to a Voltage much higher than the normal working Voltage. If the insulation is good, it stands the test without breakdown otherwise high electrical stress punctures the insulation at its weakest spot foretelling a later calamity to unwary user. Government Department- when buying electrical equipments- and all reputable manufacturers test every piece of equipment by this test called HIGH VOLTAGE TEST. It weeds out poorly insulate apparatus.
-
product
Fully Automatic Transformer Oil Test Set
OTS-A series
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
product
High Voltage, Continuity & Hipot, Cable & Wire Harness Test Systems
CableEye HVX, HVX-21
CAMI Research Inc. (CableEye®)
Fast ● Simple ● Precise
Advanced wiring analyzer scans for continuity (opens, shorts), miswires, resistance, capacitance, components (resistors, diodes, LEDs, capacitors) dielectric breakdown, insulation resistance, intermittent connections
HVX (Item 829) 1500 Vdc, 1000 Vac
HVX-21 (Item 829A) 2100 Vdc, 1200 Vac
For diagnostic and Pass/Fail Testing — Permits expanded testing (compared to models in our low voltage product line) for insulation resistance (IRI) and dielectric breakdown (DWV).
All CableEye testers are suitable for production, fault diagnosis, QC (Quality Control), assembly, and prototyping of standard or custom cables. Each combines test, fault location, design, documentation, labeling, and database storage in one instrument. Tests can be performed on long cables (with or without connectors) or no cables (e.g. connectors, backplanes, PCBs, components).
Standard Features & Benefits:- USB certified, PC-based tester for a versatile, fast, robust system with long life-cycle.
- Multilingual, dynamic, graphic-rich display (netlist & wiring schematic) provides clarity and speeds diagnostics.
- 128 Test Points, expandable to 1024 providing flexibility as your product line changes.
- User-selectable voltage to each connection group in the cable simplifies an otherwise complex process, accelerating testing.
- Programmable Ramp Up, Ramp Down, Dwell Time (same as Test Time), Trip Current, and Trip Delay (same as Soak Time) adds versatility.
- Current leakage detected during HV test phase provides a measure of insulation resistance up to 1 GΩ (HVX) and 5 GΩ (HVX-21) - any leakage current exceeding a preset limit reveals the presence of moisture, flux, or other contamination on exposed contacts.
- Real-time screening for intermittent connections for pinpointing elusive faults and improving quality.
- Automation scripting in a simple, intuitive language allowing non-programmers to reduce operator error by automating repetitive steps.
- Pop-Up Work Instructions. choose the exact amount of detail, imagery, language and automation you need to ensure your work instructions and tests are carried out flawlessly.
- Flexible tolerancing: optionally define as percentages or absolute terms, as well as asymmetrically (e.g. +0%/-10%) for improved yields.
- Barcode-tracking & archival data-logging to achieve error-proof test process and improved traceability & productivity.
- Print PASS/FAIL labels, test reports (with or without color wiring schematics/netlists) and log reports to satisfy ISO9000 reporting requirements.
- Compatible with laptop and touchscreen PCs for fieldwork and rack/off-bench mounting.
Includes:
CB29 board set (Item 759) for bare wire connections; comprehensive PC software with Database of >200 standard cables; 2 yr Product Support Subscription comprising Warranty, free tech support, and free software upgrades.
Select Add-On Options:
Hardware: 128-point Expansion Modules (attach to base); 4-Wire Kelvin Resistance Measurement, 1 mΩ at 1 A; Advanced Measurements; External Measurement Instrument Port (e.g. 10 GΩ Isolation at 100 V); Remote Control Connector for Deadman Switch; Environmental Sensor
Software: PinMap™ fixture editor, Connector Designer™ connector editor, or Autobuild™ guided assembly modules