Showing results: 2521 - 2535 of 5237 items found.
-
192190-01 -
NI
RJ50 10-pin Modular Plug to DB-9 (Male), 1m
-
510109339 -
Virginia Panel Corporation
PCB Adapter, ITA, QuadraPaddle, 192 Position, to PCB-Mounted 2x68 Pin Female SCSI Connector.
-
-
Weshine Electric Manufacturing Co., Ltd
Cable harness tester is used for test and measure wire cable harness,wire harness, like as : auto cable, audio cable, power cable, network cable, telephone cable, USD cable, HDMI cable,video cable, etc. .
-
System Software 3 -
BAUR Prüf- und Messtechnik GmbH
The BAUR system software is a cable testing, cable diagnostics and cable fault location package. It enables efficient monitoring of the condition of cable networks in combination with BAUR cable fault location, testing and diagnostics systems.
-
LKZ-720 -
Sonel S.A.
*Detection of wires and cables (live or not)**detection of cables in ceilings, walls and floors,**detection of breaks in cables,**tracing cables in building installation,**locating power points and switches in buildings,**locating short circuits between leads,**tracing shielded cables,**tracing cables in metal ducts.*Identification of fuses on the distribution board.*Tracing underground cables.*Tracing conductive water and heating pipelines.*Non-contact detection of live cables.
-
System Software 4 -
BAUR Prüf- und Messtechnik GmbH
The BAUR system software is a cable fault location, cable testing and cable diagnostics package. It enables efficient maintenance of cable networks in combination with BAUR titron systems.
-
72-6706 -
Tenma
The Tenma Multi-Network and Modular Cable Tester easily reads the correct pin configuration of 10Base-T cable (Category 5, 5e and 6), 10Base-2 cable (coax), RJ-45 and RJ-11 modular cables, 356A, TIA-568A/568B and Token Ring cable by comparing transmitting end to the corresponding receiving end
-
TDR 500 -
BAUR Prüf- und Messtechnik GmbH
Handheld Time Domain Reflectometer. The handheld time domain reflectometer TDR 500 and TDR 510 are used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on life cables through the measurement category CAT IV / 600 V (with separation filter)* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
PCE Instruments
A cable detector can locate open power cables, either live or without current, up to 300 V. A cable detector can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power to the cable being tested.Many cable detector devices can also locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy. A cable detector provides a safe way to test wall sockets for which no electrical plans or wiring information is available about the cables or their output. A cable detector is very versatile, as it ensures speed and safety when making holes in walls, ceilings and floors.
-
PCE Instruments
A cable detector can locate open power cables, either live or without current, up to 300 V. A cable detector can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power to the cable being tested.Many cable detector devices can also locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy. A cable detector provides a safe way to test wall sockets for which no electrical plans or wiring information is available about the cables or their output. A cable detector is very versatile, as it ensures speed and safety when making holes in walls, ceilings and floors.
-
TDR-410 -
Sonel S.A.
*Location damaged power cables.*Fault location copper telecom cables.*Coaxial cable fault location.*Fault location wiring infrastructure.*Detection of breaks, short circuits, damage caused by dampness and other changes in impedance of the cable.*Graphic depiction of damage the cable with automatic indication the distance to fault on the screen.
-
SC48RJ -
Whirlwind Music Distributors, Inc.
The SC48RJ Tester provides rapid, positive testing for NL4 and NL8 type multiline speaker cables, RJ45 type data cables and XLR cables.
-
Honeywell International Inc.
To install the optional cable sensor, simply plug it into the detector. The entire length of cable is an extended sensor. Additional 4 foot cable sensors (sold separately) can be connected to extend the cable and increase water sensing area even more. Note: The cable sensor jack is NOT for plugging in a power adapter. Doing so could damage the detector.**
-
SBM-1.0 -
Dynamic Load Monitoring Ltd.
The DLM Saddleback is a line tension monitor suited for more delicate cable, including telecommunication cables or large cable where a Running Line Monitor is unsuitable.