40-963-050-SF-HV -
Pickering Interfaces Ltd.
Ideal for user created termination schemes where the termination is to be on the front or remotely connected to the module by cable. Suitable cables for this product are detailed in the data sheet. Interfacing PCBs should be designed with suitable clearances for the voltage the application requires.
-
40-963-050-SM-HV -
Pickering Interfaces Ltd.
Ideal for user created termination schemes where the termination is to be on the front or remotely connected to the module by cable. Suitable cables for this product are detailed in the data sheet. Interfacing PCBs should be designed with suitable clearances for the voltage the application requires.
-
C104DFX-2SB-1A -
Pickering Interfaces Ltd.
This 104-pin female D-type connector allows users to create their own cable assemblies. Cable connection is via solder buckets - supplied without backshell. This connector is suitable for use with Pickering modules that use the 104-pin D-type connector.
-
92-960-044-F -
Pickering Interfaces Ltd.
This connector is designed to allow users to directly terminate cables with soldered connections. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical precautions are observed.
-
CL360 -
Klein Tools, Inc.
200A AC, 600V AC, 1000V DC, 60MΩ, Audible ContinuityWide jaw for measuring current in cables up to 3/0 sizes; accommodates cables of diameter up to 0.58-Inch (14.7mm)Non-contact voltage tester integrated into the jaw
-
Macom Technology Solutions Holdings Inc.
MACOM offers high-performance linear equalizers for use in high speed copper connections for Ethernet, InfiniBand and Fibre Channel. The product line supports NRZ and PAM-4 multi-level signal connectivity and builds upon MACOM’s long-standing expertise in equalizers for broadcast video applications. The equalizers can support up to 112Gbps per lane data rates for 50 Gbps to 800 Gbps copper cable assemblies. In addition to copper cables, the linear equalizer can be used for wired backplane and on-board applications. Adding linear equalization to a passive copper cable can enable the same copper cable to carry higher data rates for longer distances. MACOM’s new linear equalizer product line can extend a typical copper cable’s performance to 7.5 meters at 56 Gbps and 5 meters at 112 Gbps data rates. Customers can consider active copper cables as an alternative to passive copper cables or active optical cables. Key benefits include low power consumption from a single 3.3V supply, low latency, hardware and microcontroller management modes. The products are suitable for SFP, QSFP, QSFP-DD and OSFP connector form factors.
-
PHG 80 TD -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
PHG 70 TD -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
McGan Technology
The Wire Testing Unit (WTU) is used in conjunction with the MMPD-8K kit or the MM5KV Kit purchased with the optional HV Red Wire and is used to easily test the continuity of electrosurgical cables used to connect the electrosurgical generator either to the active handpiece (e.g. laparoscopic instruments or forceps) or to the return electrode which completes the circuit between the generator and the patient. If the conductor is broken without damage to the cable’s jacket it can remain unseen and could be put into use for the electrosurgical operation causing the system to not properly function. By using the WTU you can test to ensure that the cables have continuity prior to actual usage in the operating room. This does not preclude the other tests that should be performed on these cables such as visually examining the cable for jacket damage including cracks, pinholes and abrasions and manually flexing the cable.
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH8158 is a device for measuring the common mode interference voltage of unshielded twisted pair cables. Cable testing according to CISPR 16-1-2. The equipment under test (EuT) and auxiliary equipment (AE) are directly connected to the corresponding ports. The port adopts RJ-45 socket (the distribution conforms to T568A/B.) This equipment is divided into three specifications: CAT3, CAT5, and CAT6, and the corresponding equipment is selected according to the cable model.
-
Optical Wavelength Laboratories
MULTI-PAIR FIBER LINKS are becoming more common than single pair fiber links for high speed communications, especially in data center environments. OWL DataCenter 12 Series test kits automatically test 12-fiber MPO cables and links without requiring cassettes or fanout cables. Higher density connections (i.e. 24, 36, 48, 60 or 72) can also be tested with MPO break-out cables.
-
cPCI-J2-SCSI -
Dynamic Engineering
Ribbon cable is used between the rear IO and SCSI connector. The lengths are reasonably well matched. The cable is short. The design is intended for lower speed IO - 10 MHz and below. Above 10 Mhz there may be some attenuation.
-
310113421 -
Virginia Panel Corporation
The G12 Rear cover is designed to connect to the Receiver in a Table top configuration and act as a mean to hide the cables that are running back to the testing equipment. This works well with applications where the cables are running down to a lower level below the G12.
-
92-960-025-M -
Pickering Interfaces Ltd.
This accessory is designed to allow users to directly terminate a cable with soldered connections to the connector. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical precautions are observed.
-
40-963-096-SM -
Pickering Interfaces Ltd.
Ideal for user created termination schemes where the termination is to be on the front of the product or remotely connected to the module by cable. Suitable cables for this product are detailed in the data sheet. Interfacing PCBs should be designed with suitable clearances for the voltage the application requires.