Showing results: 4741 - 4755 of 5251 items found.
-
FE44S -
Rohde & Schwarz GmbH & Co. KG
The R&S®FE44S external frontend can extend the frequency range up to 44 GHz for Rohde&Schwarz signal and spectrum analyzers as well as signal generators. The R&S®FE44S enables signal up and downconversion directly at the device under test (DUT), lowering cable losses, increasing sensitivity and delivering more power at the antenna in an OTA environment. The R&S®FE44S uses a single RF connector to further reduce the number of antennas in over the air testing.
-
ENVIROMUX-WSS -
Network Technologies Inc
Rugged anemometer. 3-cup rotor pressed on a stainless steel shaft. Reed switch and magnet providing one pulse per rotation. Rotor diameter: 5 inches. Speed range: ~ 3 mph to 125+ mph (~5 kph to over 200 kph). Rugged Delrin body with bronze and Rulon bushings. Flat aluminum mounting bracket with 2 holes. esigned to be mounted on top of a pole or bracket. 100 feet of exterior grade wire. Maximum cable length: 1000 ft (305m).
-
780968-01 -
NI
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
780968-02 -
NI
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
785041-01 -
NI
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
784507-01 -
NI
50-Pin Male IDC to 66-Pin Female Screw, Breakout for sbRIO Terminal Block - The sbRIO Breakout Box is a 2 mm insulation-displacement contact (IDC) connector breakout that provides easy access to the multifunction I/O and digital I/O connectors on CompactRIO Single-Board Controllers. The connector breakout provides screw-terminal access to the onboard I/O, which eliminates the need to create a custom cable. You can use this accessory at your desk or mount it directly to the controller for an alternative wiring solution during deployment.
-
M9187A -
Keysight Technologies
The M9187A has 32 input channels that can be used for comparing inputs to user-defined thresholds between 0.3V and 50V, with 12mV setting resolution. Each input is protected up to 100V. In addition, the 32 output channels use a high current to drive the output high or low, and are capable of sourcing 0.4A from the high side or 0.5A sink from the low side of each channel. These outputs are protected against over-voltage or over-current conditions. Choose from the durable connector block or the standard cable connections.
-
34939A -
Keysight Technologies
The Keysight 34939A is a high density general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 64 independent single-pole, single-throw (SPST) relays that can switch 1A and carry 2A. This module can be used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The relays are 100V, 1A contacts and can handle up to 60W. Standard 78-pin Dsub connectors allow for use with standard cables, screw terminal blocks, or mass interconnect solutions.
-
Staubli Group
High-quality connection solutions for precise measuring, testing and examination. Whether low or medium voltage range, whether precise test runs or preventive measuring and testing: With an extensive portfolio of specific components and cables, Stäubli always ensures perfect and reliable contact between the measuring instrument and the points, objects and systems to be tested. In addition, we are a proven partner of leading manufacturers of measuring instruments in this field, for example for equipping them with high-quality sockets. Every product meets all quality and safety standards.
-
786502-01 -
NI
The PCIe-1477 works well for deployment systems and features a user-programmable FPGA for onboard image processing. Placed directly in the image path, FPGAs can acquire and process images with closed-loop control without CPU intervention. This technology is also suitable for high-throughput system architectures to preprocess image data on the FPGA and then send the data to the CPU for further processing and decision-making. The PCIe-1477 also supports Power over Camera Link (PoCL), which you can use to power cameras through PoCL-enabled cables.
-
783087-02 -
NI
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
783087-01 -
NI
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
ZET 7070 -
ZETLAB Company
Basic delivery scope with digital transducers for laboratory use includes the following: interface converter ZET 7070, power supply module 220V→ +24V, measuring line connector ZET 7001 (these components are mounted on a din-rail 300 mm); cable USB 2.0 A→B – length 1,8 m; terminal resistance 120 Ohm (for industrial use — steel plug); CD with ZETLAB SENSOR software, enabling connection of up to 60 digital sensors; set of operational documentation.
-
N9951A -
Keysight Technologies
44 GHz max frequency Carry world's most integrated handheld W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in a single sweep Simultaneously measure all four S-parameters Make accurate SA measurements ( 0.5 dB) without needing warm-up Easily measure average and pulse power with a USB sensor
-
N9950A -
Keysight Technologies
32 GHz max frequency Carry world's most integrated handheld W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in a single sweep Simultaneously measure all four S-parameters Make accurate SA measurements ( 0.5 dB) without needing warm-up Easily measure average and pulse power with a USB sensor