Filter Results By:

Products

Applications

Manufacturers

Similar Topics: Cables

Cable

purposed group of wires or a single optic fiber.

See Also: Cable Assembly, Cables


Showing results: 4891 - 4905 of 5251 items found.

  • Ethernet Tester

    ProPlex IQ - TMB

    Ethernet tester for entertainment production applications. Designed with input from production and staging professionals as an all-in-one device, it provides feedback and analysis on any Ethernet protocol, as well as network troubleshooting. It can act as a DMX cable tester, DMX receiver/transmitter, DMX timing analyzer, DMX recorder, RDM controller, or a bidirectional Ethernet-DMX gateway. It is also a PoE tester that can determine the capabilities of any connected PoE source. Finally, it can check SMPTE timecode or act as an LTC receiver/analyzer, and LTC transmitter, and users can use it to update Solaris/ProPlex firmware without a PC.

  • Dual Range Non-Contact Voltage Tester

    NCVT-2 - Klein Tools, Inc.

    Automatically detects and indicates low voltage (12-48V AC) and standard voltage (48-1000V AC) allowing broad application.Non-contact detection of standard voltage in cables, cords, circuit breakers, lighting fixtures, switches, outlets and wires.Non-contact detection of low voltage in security, entertainment, communications, environmental control, and irrigation systems.High intensity, bright green LED indicates the tester is operational and aids in illuminating the workspace.Digitally controlled ON/OFF power button.Auto power-off feature conserves and extends battery life.Microprocessor controlled low-battery indicator.CAT IV 1000 Volt rating provides expanded operation and protection.

  • Portable Dew Point Monitor

    1500 - Edgetech Instruments

    The Model 1500 is a self contained system; not only is there no field assembly required, there’s no need to carry around a myriad of individual components such as control boxes, sensors, cables, pumps, and power cords. Simply attach the sample line, adjust the flow (with the integral flow meter) and turn on the power. Within minutes you’ll be collecting field dew point data with the same chilled mirror accuracy of a lab standard hygrometer. And with a nominal battery life of 12 hours, you will be able to collect for the entire shift or spot check your processes for several days.

  • Motion Based Waves

    Aanderaa Data Instruments AS

    Accurate Motion Based wave measurements are critical in applications such as offshore wind farm development, navigation, cable laying, breakwater building, and bridge construction.Waves also result in continuous loads on marine structures, including docks, moorings, and offshore platforms.Motion Based Waves are challenging to measure. Variables to consider when collecting wave data include the depth of the measuring device, proximity to shore, wave types, and available infrastructure from which to measure.Several methods for measuring motion based waves are available, and careful selection of the best approach is needed to get the optimal result.

  • Low-Profile High-Performance IEEE488 GPIB Interface for PCI Bus

    LPCI-3488A - ADLINK Technology Inc.

    ADLINK LPCI-3488A GPIB controller interface card, fully compatible with the IEEE 488 instrumentation control and communication standard, is capable of controlling up to 14 stand-alone instruments via IEEE 488 cables. It is designed to meet the requirements for high performance and maximum programming portability. The built-in 2KB FIFO and a block transfer mode provide up to 1.5 MB/s GPIB transfer rate. With the APIs that are compatible with NI-488.2* and VISA support, the LPCI-3488A provides the greatest compatibility with your existing applications and instrument drivers. (* NI-488.2 mentioned here is the trademarks and properties of National Instruments Corporation.)

  • Closed-Link Field Test Kit

    630 - The Eastern Specialty Company

    TESCO’s Closed-Link Field Test Kit (Catalog No. 630) with Power Factor has been designed to reduce the weight of field test equipment to the lowest possible limit when testing electric meters without potential links or with the links closed. The unit is protected within its ergonomic carrying case by a durable powder coated aluminum shell. The total weight of the meter test kit including leads, and digital reference standard is only 30 lbs! The test kit carrying case also incorporates ample storage space for the cable set and other tools.

  • PXIe-8301, Thunderbolt™ 3 PXI Remote Control Module

    785679-01 - NI

    Thunderbolt™ 3 PXI Remote Control Module—The PXIe-8301 enables laptop control of a PXI Express chassis over a Thunderbolt™ 3 connection. Using a Gen 3 x4 PCI Express link, the PXIe-8301 allows up to 2.3 GB/s of sustained data throughput between the chassis and laptop over a Thunderbolt 3 USB Type-C cable. An additional Thunderbolt 3 port allows for connecting additional Thunderbolt or USB-C devices. Thunderbolt and the Thunderbolt logo are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries.

  • This Computer-on-Module Starter Kit

    COM Express Type 6 Starter Kit Plus - ADLINK Technology Inc.

    The Type 6 Starter Kit Plus consists of a COM Express Type 6 module with ATX size Type 6 reference carrier board that offers one PCI Express x16 slot with proprietary pinout for DDI adapter card that convert DDI signal to DP or HDMI signal, one PCI Express graphics x16 slot, one PCI Express x4 slot, three PCI Express x1 slots, Serial ATA, VGA, LVDS, USB3.0/2.0, Gigabit LAN and Super I/O. All necessary cables are included.

  • Digital Interconnect Test System, Reference Solution

    Keysight Technologies

    When you need to measure advanced S-parameters with a fast, low-cost and easy-to-use test solution, the Digital Interconnect Test System gives you a significant edge. It provides a full 32-port vector network analyzer (VNA) configured within a single PXI chassis – ideal for high-speed cable testing. And lets you test any linear passive interconnect faster and easier, including backplanes, connectors and PCBs. Sharpen your edge with Keysight’s Digital Interconnect Test System that enables signal integrity characterization of multiport interconnect products.

  • NI TB-2640B Terminal Block for NI 2532B as 1-Wire 4x128 Matrix Topology Without Column Protection Resistors

    782385-01 - NI

    Screw Terminal, Ribbon, 4x128, 1-Wire PXI Module Matrix Terminal Block - The TB-2640B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 1-wire 4x128 matrix. You can directly connect the TB-2640B to the front panel I/O connectors … of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2640B also provides optional isolation resistors to protect the reed relays from capacitive loads.This 782385-01 card does NOT have 100 Ohm protection.

  • PXI Matrix Switch: 8x32, 1-Wire, 100Vrms/2A, Armature Relays

    M9122A - Keysight Technologies

    The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.

  • 110 GHz Frequency Extender, Pulsed DC Bias

    N5293AX52 - Keysight Technologies

    The Keysight N5293AX52 is a broadband frequency extension module designed for use with Keysight’s new PNA / PNA-X-based millimeter-wave solutions. It is a compact, lightweight, and ruggedize frequency extender module with built-in bias tee for pulsed DC bias operation. It interfaces with the Keysight N5292A test set controller. The modules allow users to extend the frequency coverage of a base PNA / PNA-X Series network analyzers to a range of 10 MHz to 110 GHz. For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • Handheld Water Quality Meters

    LAQUA PD220 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • Compact HD Thermal Camera

    FLIR A8580 MWIR - Teledyne FLIR

    FLIR A8580 MWIR cameras provide the crisp imagery, accurate temperature measurement, and streamlined analysis features needed for industrial, military, and manufacturing R&D applications. The 1.3 MP detector produces high definition thermal images, while the suite of manual and remote focus lenses allow users to maximize the number of measurement pixels on their target. Simple, single cable connectivity using Gigabit Ethernet or CoaXPress provides complete camera control plus data capturing in FLIR Research Studio software, so users can analyze and understand data faster than ever before.

Get Help