Filter Results By:

Products

Applications

Manufacturers

Dielectric Test

Check of a materials ability to prevent or reduce transmission.

See Also: Tan Delta


Showing results: 91 - 105 of 152 items found.

  • Transformer Oil Dielectric Breakdown Voltage Tester

    MG-II - Chongqing Kailian Yongrun Industrial Co.,Ltd.

    The dielectric breakdown voltage test (BDV test) is an important test to determine the breakdown voltage of insulating oils. After a certain period, transformer oil will be degraded, and there are moisture, gas and impurity in oil. Then, the quality of transformer oil is affected. So it is necessary to test the transformer oil. BDV test is one of the most common tests to insulating oils.

  • Automatic Oil Tan Delta & Resistivity Kit

    MOTR - The Motwane Manufacturing Company

    Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.

  • High Voltage Switch

    6TL Engineering

    FastATE technology: Modular, scalable and top flexible approach Minimum wiring and easy maintenance 19” rack, 1U, 2U, 4U or 6U depending on number of Channels Ideal for Hipot test, dielectric strenght test, High value resistors measurement. CE compilant, ESD safe CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available

  • Rubber Testing Equipment

    Dongguan Amade Instruments Technology Co., Ltd

    Rubber testing equipment are used to test the physical properties, chemical properties, thermal properties of uncompounded and compounded rubbers at prescribed conditions to help manufactures or researchers in comprehending the characteristics, updating the formula and improving product quality. Including volatile component, ash content, Mooney viscosity, vulcanization curve, Mooney scorch time, hardness, tensile properties, tearing, the compression performance, impact, friction resistance, fatigue resistance, peel strength, vertical & horizontal combustion, smoke density, limiting oxygen index, the flame spread rate, the surface resistance, surface resistivity, volume resistivity, the breakdown voltage, dielectric strength, dielectric loss, antistatic properties, Aging test (UV, Xenon lamp, carbon arc lamp, ozone) etc.

  • Precision Impedance Meter

    1689 - IET Labs

    The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.

  • Power Transformer Automatic Test Device

    XD71 - Hangzhou Xihu Electronic Institute

    The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.

  • High Voltage Tracking Resistance (HVTR)

    UL 746A - National Technical Systems

    The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).

  • High-Precision High-Voltage Capacitance Bridge

    QS30A - Shanghai Launch Electric Co., Ltd.

    QS30A high-voltage bridge takes use of combined line of current-comparator and Schering bridge. It is featured by reliable and easy operation, high precision, good linearity, automatic process of data, direct display on the panel capacitance, dielectric loss tgδ, test voltage and current flowing through the standard capacitor (Icn). It is widely used and reliable.

  • Digital 5KV High Voltage Insulation Tester

    Model KM 6305IN - Kusam Electrical Industries Limited

    • Microprocessor-controlled.• Tests insulation resistance up to 10 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V.• AC / DC Voltmeter.• Short-circuit current up to 5mA• PI (Polarization Index) indication.• DAR (Dielectric Absorption Ratio) indication.• Auto-ranging on all insulation ranges.

  • Testing Services

    ION Corporation

    *Programmable Multipoint Tester*Over 8,000 programmable test points (DWV, Capacitance, Insulation Res., 2/4-Wire Resistance, etc.)*1500VDC / 1000 VAC Dielectric Withstanding Voltage (DWV)/ Hi-Pot (Programmable Dwell times)*Full Electronics laboratory complete with state of the art testing equipment*Custom Unit Testing (Designing of Specialized Test fixtures)*EMI Testing*Temperature and Humidity Testing*Shock Testing*Vibration Testing*Sand and Dust / Altitude Testing*Military Qualification Tests Performed

  • Impulse Spark Tester

    IT-25B - Clinton Instrument Company

    While most military standards now favor high frequency spark testing over impulse spark testing, the IT-25B Impulse Spark Tester is available for use in some aeronautic applications that still specify the impulse method. The IT-25B meets the test requirements of military specifications MIL-C-13777E, MIL-W-16878, and NEMA standards for hook-up wire used in high temperature wire applications. This method is favored as an alternate to a wet dielectric test.

  • Hipot Tester

    Sentinel - Seaward Electronic Ltd

    The Sentinel series of test instruments has been built to provide a cost effective, yet powerful solution to hipot testing, whether on a production line or in a laboratory environment for compliance testing purposes. With the ability to perform either 5kV AC or 6kV DC dielectric strength tests and up to 500VA AC power output the Sentinel series can aid testing to many international safety standards including IEC, EN, UL and CSA to name but a few.

  • Insulation & Multifunction Tester (OLED Display)

    1152 MF-M - Standard Electric Works Co., Ltd

    ● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ratio (DAR).● BS 16 edition.

  • Insulation & Multifunction Tester (OLED Display)

    1155 TMF-M - Standard Electric Works Co., Ltd

    ● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Polarization index (PI).● Dielectric Absorption Ratio (DAR).● BS 16 edition.

  • Multifunctional Safety Tests

    LXinstruments GmbH

    Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test

Get Help