Filter Results By:

Products

Applications

Manufacturers

Bridge Amplifiers

Increase a transducers signal to measurable levels.


Showing results: 31 - 45 of 48 items found.

  • Interfaces And Control Boards

    Holding Informtest

    Acts as a bridge between a machine, motor controller, or PLC and related drive amplifier, feedback device and/or software.

  • 0-10V Load Cell Amplifier

    Type 132 - Datum Electronics, Ltd.

    The Type 132 Amplifier is designed to amplify the signal from any load cell with full bridge connection, allowing the user to use the data from the load cell in a more efficient and productive way.The Type 132 Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor. It can be calibrated to provide a 0-10V output for a fixed load range from the sensor.

  • 4-20mA Load Cell Amplifier

    Type 131 - Datum Electronics, Ltd.

    The Type Load Cell 131 Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor allowing the user to use the data from the load cell in a more efficient and productive way.The Type 131 Load Cell Amplifier is designed to interface to a full bridge strain gauge based load cell or similar sensor. It can be calibrated to provide a 4-20mA output for a fixed load range from the sensor.

  • High Speed Phase Inverter - Buffer

    WMA-IB-HS - Falco Systems

    The WMA-IB-HS can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision, high speed and low noise. Because of its high bandwidth, the WMA-IB-HS model is ideal for the Falco Systems WMA-100 or WMA-300 amplifiers. It can also be used with all other Falco Systems HV amplifiers, or even with high voltage amplifiers of another brand.

  • Ultra-low Noise Phase Inverter - Buffer

    WMA-IB-LN - Falco Systems

    The WMA-IB-LN can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision and ultra-low noise. The WMA-IB-LN model has been designed specifically for the Falco Systems WMA-200 high voltage amplifier. Two WMA-200 amplifiers combined with one WMA-IB-LN provide unprecedented noise performance and output voltage range.

  • Load Cell Amplifiers

    Datum Electronics, Ltd.

    Datum Electronics load cell amplifier range is designed to increase (or amplify) a signal, generated by a strain gauge load cells with a full bridge connection, pressure transducers or torque sensors, allowing the user to use the data from the load cell in a more efficient and productive way.

  • Remote Displays

    HS Series - Load Cell Central

    Load cell / scale remote displays are driven from another digital indicator or amplifier. Often used on bridge cranes and truck scales, or in any situation which the person needing to see the scales displayed weight is too far to see the smaller standard indicators. Many styles, digit sizes, indoor and outdoor models are available.

  • Programmable Signal Conditioning

    DTX 5000 Series - R.C. Electronics, Inc.

    The DTX-5000 Signal Conditioner Series provides up to 64 channels of state-of-the-art signal processing in a compact (5U) chassis. Using hybrid mixed-signal technology, high-performance analog circuitry is combined with Digital Signal Processing to give gain accuracy performance previously available only in larger customized modules. A simple-to-use graphical user interface running under the Windows 2000 operating system allows for ease of setup and either local or remote operation as a network-based instrument node. The suite of conditioner modules include a strain amplifier with internal bridge completion, a general-purpose instrumentation amplifier with selectable AC or DC coupling, a linearized thermocouple amplifier with cold-junction compensation, a frequency-to-voltage converter with dual inputs for direction sensing, and an ICP accelerometer amplifier with constant-current excitation.

  • Precision Resistor Network

    Analog Devices Inc.

    Analog Devices provides a portfolio of quad resistor networks with excellent matching specifications over the entire temperature range. All of our resistors can be accessed and biased independently, making them a convenient and versatile choice for any application that can benefit from matched resistors. Our resistor networks provide the precise ratiometric stability required in highly accurate difference amplifiers, voltage references, and bridge circuits.

  • Turnkey Laboratory Acquisition Systems

    Pacific Instruments, Inc.

    Series 6800 for laboratory applications is a ready-to-run, high performance measurement system. Enclosures are 3U rack mountable or can be used right on the desktop. 6800 units come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers, BNC for voltage or ICP/IEPE inputs or a 3-wire military grade connector.

  • Load Cell DIN Rail Signal Amplifier

    LCD20 - Mantracourt Electronics Ltd

    Our intelligent strain gauge bridge amplifier is a compact, stackable microprocessor based unit specifically designed to control and monitor process applications. Flexible connection to most load cells, pressure or strain gauges over a wide range of sensitivities. The unit provides isolated current 4-20mA and voltage 0-10V analogue outputs and two digital inputs. Two set point relays can be configured to set thresholds such as net, gross, peak and valley. Powered from a wide ranging DC supply, the DIN rail amplifier is supplied with 2 part screw connectors for ease of installation.

  • Turnkey Portable Acquisition Systems

    Pacific Instruments, Inc.

    Series 6800 for portable applications is a ready-to-run, high performance measurement system that is DC powered for mobile applications. All connections are front mounted for easy installation in tight places or on the go. 6800 systems come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers or BNC for voltage or ICP/IEPE inputs.

  • Signal Conditioning System

    28000 - Precision Filters, Inc.

    The Precision 28000 Signal Conditioning System makes it easy to manage a test with up to 256 channels of fully programmable transducer conditioning. Choose a mix of bridge, charge, IEPE w/TEDS, voltage (filter amplifier), strain, thermocouple, RTD/potentiometer, frequency, or other transducers. Self-tests traceable to NIST. 4, 8 and 16-slot rugged and transportable mainframes feature integrated cooling. Customize the 28000 for high-speed transient applications, static applications, or a combination of both.

  • Universal Signal Conditioner

    Model UDA - tecsis LP

    Model UDA is a universal signal conditioner and amplifier designed for use with all full bridge, strain gage-based transducers. Model UDA turns the analog signal into a user-selectable output of ±5Vdc, ±10Vdc, or 4-20mA. This versatile unit features selectable excitation of 2.5 or 5.0Vdc bridge voltage and has a wide DC power input range from 11 to 28Vdc to adapt to a variety of installations. Model UDA includes a wide zero and span adjustment range and a symmetry adjustment for applications requiring precision in both tension and compression. The configurable low pass filter actively removes unwanted high frequency signal components. The unit is housed in a rugged DIN-mountable enclosure with screw terminals to provide connection for power, analog output, shunt calibration, and sensor signals.

  • Energized Cable Sensor

    Hubbell Power Systems Inc

    The purpose of the Energized Cable Sensor is to allow the lineman to readily determine whether a URD cable is energized. The sensor consists of an amplifier which is designed to give a meter reading when the small AC voltage between the semi-conductive sheath and the concentric neutral of the energized URD cable is applied to the test probe. The amplifier is housed in a rugged phenolic case. Sensor may be used to check for energized condition on concentric-neutral cable below an elbow without test points. At cable mid-span (left), hose clamps bridge all strands of concentric neutral at the test location. Sensor’s neutral lead clips to one of the hose clamps. Tip on probe lead contacts only semi-conductive cable sheath to test for voltage presence.

Get Help