Filter Results By:

Products

Applications

Manufacturers

Carriers

Carrier devices are practical for adapting your product to a standard interface for testing on the bench or in the chamber.


Showing results: 706 - 720 of 732 items found.

  • SWB-2812, 16x9, 1 A, Reed Matrix Module for SwitchBlock

    781420-12 - NI

    16x9, 1 A, Reed Matrix Module for SwitchBlock - The SWB‑2812 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2817, 16x22, 0.3 A, Reed Matrix Module for SwitchBlock

    781420-17 - NI

    16x22, 0.3 A, Reed Matrix Module for SwitchBlock - The SWB‑2817 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • SWB-2812, 16x9, 1 A, Reed Matrix Module for SwitchBlock

    781421-12 - NI

    16x9, 1 A, Reed Matrix Module for SwitchBlock - The SWB‑2812 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.

  • Oscilloscope

    MOSTS6 - Holding Informtest

    *MOSTS6 is the first Russian instrument (oscilloscope) with a direct sampling rate (8bit ADC), 5 Gigasemp / s per channel. M-module MOSTs6 is designed to work as a part of information measuring systems based on the VXI bus magister as a digital oscilloscope. The M-module is made in the form of a triple-width mezzanine, is installed on a mezzanine carrier and is connected to it via a local information highway.*MOSTS6 is designed to convert instantaneous voltage values ​​of an electrical signal into a digital code, measure instantaneous voltage values, measure time intervals between two instantaneous voltage values ​​through two independent channels.MOSC6, according to the conditions of use, meets the requirements for measuring instruments of group 3 in accordance with GOST 22261-94.

  • Quality Measurement Tools for Voice, Audio/Visual and Data Payload analysis

    PEXQ - OPTICOM GmbH

    PEXQ is OPTICOM’s latest product for Windows offering a complete portfolio of quality measurement tools for voice, audio/visual and data payload analysis based on human perception. PEXQ provides mandatory features in the area of R&D for the development of new multimedia codecs as well as for multimedia equipment manufacturers. Besides lab testing PEXQ is also ideal for network operators and carriers to measure quality of service. PEXQ is founded on well established internationally standardized measurement algorithms such as PESQ (ITU-T Rec. P.862, P.862.1 (narrow band), P.862.2 (wide band); Perceptual Evaluation of Speech Quality) and completely new metrics for video quality testing like PEVQ (Perceptual Evaluation of Video Quality).

  • CompactPCI

    3U PMC Carrier - PCI EmbeddedComputer Systems

    This conduction cooled 3U CompactPCI single slot PMC provides an active interface between the CompactPCI bus (backplane) and a PCI Mezzanine Card (PMC). This product addresses the needs of aerospace, military, and rugged applications. It contains a thermal heat frame made of aluminum that fits together with conduction cooled PMC modules. Conduction cooling conducts heat away from the hot spots of the board and transfers the heat to the card edges and to the system chassis. No active ventilation is necessary inside of the system, which means the boards are sealed from the environmental influences found outside of the chassis. The heat frame and integrated wedge locks for the conduction cooling stiffens carrier and PMC module enabling the board to resist high shock and vibration.

  • CompactPCI

    6U PMC Carrier - PCI EmbeddedComputer Systems

    This conduction cooled 6U CompactPCI dual slot PMC provides an active interface between the CompactPCI bus (backplane) and a PCI Mezzanine Card (PMC). This product addresses the needs of aerospace, military, and rugged applications. It contains a thermal heat frame made of aluminum that fits together with conduction cooled PMC modules. Conduction cooling conducts heat away from the hot spots of the board and transfers the heat to the card edges and to the system chassis. No active ventilation is necessary inside of the system, which means the boards are sealed from the environmental influences found outside of the chassis. The heat frame and integrated wedge locks for the conduction cooling stiffens the carrier and PMC module enabling the board to resist high shock and vibration.

  • MIL-STD-1553 MCH

    M4K1553MCH - Excalibur Systems, Inc.

    The M4K1553MCH interface module for the multimode, multiprotocol, Excalibur 4000 family of carrier boards provide a complete solution for developing and testing 1553 interfaces and performing system simulation of the MIL-STD-1553 bus. The module handles all standard variations of the MIL-STD-1553 protocol.The M4K1553MCH contains 32k x 16 of dual-port RAM for Data blocks, Control registers, and Look-up tables. All Data blocks and Control registers are memorymapped and may be accessed in real time. The dual-redundant 1553 module may be programmed to operate in one of four modes of operation: Bus Controller, Remote Terminal, RT/Concurrent-Bus Monitor, and Bus Monitor. The M4K1553MCH comes complete with Windows software, and a C driver software library including source code.

  • Ethernet MACsec PHY

    Macom Technology Solutions Holdings Inc.

    IEEE 802.1AE Media Access Control Security (MACsec) is an industry standard security technology that provides secure communication for Ethernet traffic. MACOM’s wire-speed Ethernet MACsec PHY products offer highly scalable and cost-effective encryption solutions to address the data security issues in wireless, carrier, data center and cloud networks. Combining MACOM’s strength in high speed, high performance mixed-signal I/O and industry leading CMOS silicon technology, MACOM’s MACsec PHY products provide line-rate encryption and authentication at a very low power-footprint that enables encryption at wire-speed on every port. They are ideal for adoption on switch/router line cards, data center interconnect (DCI) transponder and wireless xHaul aggregation systems to provide security function in addition to the connectivity to optical and copper modules.

  • Dual Vapor Gravimetric Sorption Analyzer

    DVS Resolution - Surface Measurement Systems

    DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.

  • 60 GHz WR-15 Waveguide Tx Module

    PEM010 - Pasternack Enterprises, Inc.

    The PEM010 is a highly integrated millimeter wave transmitter that covers the 60 GHz global unlicensed spectrum allocations packaged in a standard waveguide module. Transmitter architecture is a double conversion, sliding IF with wide bandwidth capability through the up-conversion chain from baseband to carrier. The I/Q interface accepts analog baseband signals which provides for flexibility in design and applications. The baseband input optionally supports FSK/MSK modulation for non-coherent applications. The transmitter incorporates a complete waveguide interface with low-loss transition between the chip and the WR15 waveguide port. The integrated package is small and lightweight, with a simple to use multi-pin ST4 connector for power, reference clock, digital control port and baseband signals. Either of two reference clocks can be used for setting 540 MHz or 500 MHz channel spacing.

  • MIL-STD-1760

    M4K1553Px(S)-1760 - Excalibur Systems, Inc.

    The M4K1553Px(S)-1760 interface module for the multimode, multiprotocol, Excalibur 4000 family of carrier boards provide a complete solution for developing and testing MIL-STD-1760 interfaces and performing system simulation of the MIL-STD-1760 bus. The module handles all standard variations of the MIL-STD-1760 protocol.Each M4K1553Px-1760 multi function module contains 64K bytes of dual-port RAM for Data blocks, Control registers, and Look-up Tables. All Data blocks and Control registers are memory mapped, and may be accessed in real time. Each of the independent dual redundant M4K1553Px-1760 modules may be programmed to operate in one of three modes of operation: Remote Terminal, Bus Controller/Concurrent-RT, and Bus Monitor. In addition, modules 1 and 3 can be programmed to operate as Concurrent monitors, to modules 0 and 2 respectively.

  • Broadband Diagnostics

    TruVizion - ZCorum

    TruVizion gives you a comprehensive view into the health of your cable or DSL network, including up to 90 days of historical data.PreEqualization Analyzer lets you quickly find upstream impairments like reverse splitters, loose or corroded connectors and bad wiring. Plus, you can be proactive and actually fix those problems before they affect service for your subscribers.RF Inspector is an inexpensive app that can do what a meter can do, except it can do it on a tablet from wherever you happen to have Internet access. That means in the office, at home, or in the field.Upstream Analyzer shows you the RF signals for all ports and modems on your Cisco CMTS without any additional equipment, cabling or connectors, and yes, you can see ingress under the carrier with one click.

  • OnyxFX FlexorSet 4-Ch. 250 MHz A/D, 2-Ch. 800 MHz D/A - 3U VPX

    Model 5973-312 - Pentek, Inc.

    - Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Four 250 MHz 16-bit A/Ds- One digital upconverter- Two 800 MHz 16-bit D/As- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 and 3) interface up to x8- User-configurable gigabit serial interface- Optional optical Interface for backplane gigabit serial interboard communication- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-66.4 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Also available as Model 7070-312- See comparable JadeFX Xilinx Kintex UltraScale FPGA Family:Model 5983 JadeFX Kintex UltraScale Processor and FMC Carrier - 3U VPX

  • Compact Digital Receiver

    DCR822 - Lectrosonics, Inc.

    The DCR822 compact 2-channel digital receiver with analog and digital audio outputs utilizes the Lectrosonics signature digital architecture with remarkable audio quality and ultra-low latency. The receiver includes an extended operating range rivaling the best analog and Digital Hybrid Wireless® systems with continuously tunable tracking filters covering 470.100 - 614.375 MHz. The innovative Vector Diversity technology raises the bar for digital transmission integrity with two RF front ends per channel, and a unique phase-matching system. The extremely robust RF front ends of the receiver will hold up in severe RF environments and close carrier spacing, whether analog or digital. The DCR822 has a flexible output routing scheme, allowing a variety of applications including Talkback. And, a digital recorder at 24 bits, 48 kHz is included – and records up to 4 audio tracks on a front-mounted microSD card.

Get Help