Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 175 items found.

  • High-Speed High-Voltage Power Amplifier

    Model 20/20C-HS - TREK, INC.

    The Model 20/20C-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all solid- state design for high slew rate, wide bandwidth and low noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

  • High-Speed High-Voltage Power Amplifier

    Model 10/40A-HS - TREK, INC.

    The Model 10/40A-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all-solid-state design for high slew rate, wide bandwidth and low-noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

  • Saluki SPA Series Solid State Power Amplifier (max. 23KW output power)

    Saluki Technology Inc.

    Saluki SPA series is a solid-state RF power amplifier with an output frequency of maximum 110GHz and an output power of a maximum of 23000W. Its design is based on the most advanced GaN technology in the industry, and its power output is efficient and reliable. The product has functions such as temperature and current detection, alarm protection and so on.The broadband solid state power amplifier is mainly used for testing and measuring instruments, Communication or interference, aviation control and other fields.*Customization Available*

  • Transimpediance Amplifiers

    Gamma Scientific Inc.

    The UDT TRAMP products are transimpedance amplifier (current-to-voltage) instruments that provide a low input impedance to accurately measure the short circuit current of phototransducers such as silicon and germanium photodetectors, vacuum photodiodes and photomultiplier tubes. The range includes the economically priced TRAMP, and for ultra precision and accuracy, the TIA-3000.

  • Light-to-Analog Sensors (Voltage)

    Renesas Electronics Corp.

    Renesas' light-to-voltage silicon optical sensors combine a photodiode array, a non-linear current amplifier and a micropower op amp on a single monolithic IC. Applications for these devices include display backlight control, keypad dimming, anti-glare mirror systems, and industrial and medical light sensing applications.

  • High Speed High Voltage Amplifier

    WMA-320 - Falco Systems

    The WMA-320 is a high voltage, wide bandwidth laboratory amplifier. Its high output voltage, current and wide bandwidth have been designed to serve the needs of a wide variety of high-tech experiments. The WMA-320 can be used for MEMS actuation, EO-modulators, PZT (piezo) positioners, ultrasonics, and many other applications.

  • High-Voltage Power Amplifier

    Model 40/15 - TREK, INC.

    The Model 40/15 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slewrate, wide bandwidth, and low-noise operation. It is configured as noninverting with a fixed gain of 4000 V/V and is protected against overvoltage and overcurrent conditions that may be generated by active loads or by output short circuits to ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or for use as feedback signals in a closed-loop system.

  • Light Sensor

    NaPiCa - Panasonic Industrial Devices Sales Company of America

    Visible light sensor (Silicon Photo IC) that detects light and converts into electrical current. Consists of a photodiode and built-in amplifier. Optical filter provides spectral response similar to human eye sensitivity. Applications include: LCD Backlight Control, Commercial and Residential Lighting Brightness Control, Security Lighting.

  • Single Phase Lock-In Amplifier

    SR510 - Stanford Research Systems, Inc.

     The SR510 and SR530 are analog lock-in amplifiers which can measure AC signals as small as nanovolts in the presence of much larger noise levels. Both the single phase SR510 and the dual phase SR530 have low-noise voltage and current inputs, high dynamic reserve, two stages of time constants, and an internal oscillator. 

  • Gated Integrator | Boxcar Averager

    GIA100 - Artifex Engineering GmbH & Co. KG

    The GIA100 gated integrator employs dual monolithic switched integrators. When paired with a photodiode, the boxcar amplifier measures the energy of single optical pulses. The GIA100 design results in very low leakage error, charge injection error and pickup. The precision input stage may be configured for current or voltage inputs.

  • Power Amplifier

    5241 - Magtrol Inc.

    The Model 5241 is a voltage-controlled power amplifier designed exclusively for Magtrol's Model HD-825 Hysteresis Dynamometer. Because of its double braking system, the HD-825 requires more than 4 amps of power in order to reach full torque. The 5241 (which can provide up to 5 amps of output current) is necessary in order to amplify the power between a 6200 or DSP6001 Controller (which both have a maximum current output of 1 amp) and the HD-825 Dynamometer.

  • Trip Amplifiers

    Datexel

    Datexel manufacture a large range of Trip Amplifiers and Process Limit Alarms that accept universal inputs and provide either relays or NPN or PNP transistor outputs. The DAT5028 is also an isolated signal converter and has a local display with up to 4 relays and is DIP switch programmable. The inputs can be Thermocouples, RTD, mV, mA, Resistance, Potentiometers or Voltage. They can be supplied fully configured set up by PC or DIP switches. The DAT5024 is a trip Amplifier / Temperature limit alarm for RTD's, Thermocouples, Voltage, Resistance and Current with the option of 1 or 2 relay outputs hysteresis and delay timers. The DAT5024 E range is an economical choice with DIP Switch programmable for voltage or current input. Either 1 relay or 2 relays (SPDT) are available with delay timers.

  • Multiplying Current Output D/A Converters

    Analog Devices Inc.

    Analog Devices offers a wide range of high precision, multiplying current output (IOUT) D/A converters (DACs) that feature ±1 LSB INL and DNL specifications, from 12-bit up to an industry-leading 18-bit resolution. Our portfolio includes single and multiple D/A converters in small packages with parallel or serial SPI interfaces. Multiplying current output R-2R D/A converters allow for an external amplifier that’s optimized for specific applications and that does not require reference buffering, which enables high linearity. The SoftSpan™ feature allows software selectable output spans, therefore eliminating the need to add precision gain stages and the associated external jumpers, precision resistors, and amplifier circuitry. Integrated precision resistors allow for reference inversion, bipolar offset, and offset and gain adjustment.

  • Operational Amplifiers

    ams AG

    Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.

  • Integrated

    Columbia Research Laboratories

    Columbia's Integrated Accelerometers are completely self-contained vibration measuring systems having a built-in amplifier within the housing. Low output impedance allows operation directly into standard readout equipment without auxiliary signal conditioning. This type of accelerometer must be powered by a constant current power supply like Columbia's model 5421.

Get Help