Showing results: 886 - 900 of 1185 items found.
-
50-200-008 -
Pickering Interfaces Ltd.
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
50-200-004 -
Pickering Interfaces Ltd.
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
3PK-NT007N -
Prokit's Industries Co., Ltd.
Multi-network cable tester is specified to quickly test by auto scanning the wires continuity, miss-wiring and polarization in your network cables, thin Ethernet (BNC)/10 Base-T (UTP/STP)/356A/ TIA-568A/TIA-568B/Token Ring. By using the attached remote terminator, you can easily test the cable whatever before or after the cables installed. It also allows you to test the ground of shielded twisted pairs cables.
-
Uprog -
RK-System
Uprog is universal device programmers family. It uses LPT parallel port or USB for communication with PC.Graphical interface of Uprog software is very confortable in usage for programming and testing tasks. Uprog programmers have 100% universal programming socket. They allow to put independly on any pin programming voltage (0-30V), power supply (1.8-8V), ground or clock, so this flexibility allow Uprog programmers to handle any device.
-
Osborne Transformer Corp.
Osborne’s Isolation Transformers are used to step-up, step-down and isolate voltages in single phase circuits. Isolation may be used to provide output circuit immunity from voltage spikes and noise (both common-mode and transverse-mode) present on the input system. The isolation can allow separate grounds on both the input and output sides of the transformer. Osborne also designs with a range of electrostatic shielding to provide several levels of noise immunity.
-
DSL Xpert™ -
TraceSpan Communications Ltd.
The patent-pending DSL Xpert multi-layer analyzer broke new ground as the only non-intrusive performance analysis solution for ADSL2Plus, ADSL2 and ADSL products. It is a modular tool designed for R&D and laboratory engineers engaged in the deployment of ADSL2Plus, ADSL2 and ADSL standard-compliant solutions. Cutting significant time from ADSL development, deployment, debugging and interoperability verification, DSL Xpert� accelerates time to market and return on investment.
-
CT8007 -
General Technologies Corp.
No ground wire means no wire tangles nor time lost searching for grounding points. High Impedance electronic circuitry. Negligible current draw ( 1 microampere) is 30,000 times less than regular lamp type testers. This gives complete safety when working around sensitive electronic control modules and sensors. Operating range between 6 and 28 Volt DC in battery powered systems
-
AudioJog Rack 8 -
CableJoG Ltd
There are 2 rows of 9 LED's corresponding to each of the possible connector pins and one for the screen (or ground) connection. As each pin is activated, the LED's indicate all connections associated with that pin, so that short, open and crossed circuits can be easily found. The LED's also show the possibility of high resistance or leakage connections. 2 LED's indicate a good digital network connection, either Straight through, or Crossed over.
-
294 -
SCI
Our Model 294 is a simple-to-use DC Hipot Tester with the built-in ability to test Ground Continuity (Low Current Continuity). The 294 DC Hipot Tester includes all the features you need to get the job done and move on. Make testing simple with common sense security settings. PLC Remote allows you to make DC Hipot Testing safer with Personal Protective Equipment (PPE).
-
297 -
SCI
Our Model 297 is a simple-to-use Hipot Tester with the built-in ability to easily test Insulation Resistance and Ground Continuity (Low Current Continuity) in a one-box solution. The 297 is capable of performing Hipot Tests in both AC & DC currents. Make testing simple with common sense security settings. PLC Remote allows you to make Hipot Testing safer with Personal Protective Equipment (PPE).
-
296 -
SCI
Our Model 296 is a simple-to-use Hipot Tester with the built-in ability to easily test Ground Continuity (Low Current Continuity). The 296 is capable of performing Hipot Tests in both AC & DC currents. You need a Hipot Tester that includes all the features you need to get the job done, the 296 has what you're looking for Make testing simple with common sense security settings.
-
780877-01 -
NI
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
783740-01 -
NI
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
779012-01 -
NI
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
5047 -
Abaco Systems Inc
The 5047 provides breakout of all ECM signals for debug, design validation and development. Plated through holes on the PCB allow soldering of probe wires to IO, Data, Power and Serial Identification signals. LEDs indicate presence of 3V, 5V, +12V, -12V and Ground. Elevates the ECM module by 2 mm and saves wear on the ECM carrier board connectors. Since this is a debug too there is no serial identification circuit.