Filter Results By:

Products

Applications

Manufacturers

Harmonic

Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.


Showing results: 271 - 285 of 324 items found.

  • MXG X-Series Microwave Analog Signal Generator, 9 kHz to 40 GHz

    N5183B - Keysight Technologies

    Get a fast, compact (2U) alternative to the PSG in the lab, depot or fieldAddress demanding tests of radar modules & systems with near-PSG levels of spectral purityCompensate for system loss & drive high-power amplifiers: +19 dBm output power, -55 dBc harmonics & -68 dBc spurious @ 20 GHzReduce calibration time with switching speed 600 sSimulate narrowband chirps & radar antenna scans with up to five internal function generators that can be used with AM, FM, OM pulse modulation

  • NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    783311-01 - NI

    ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.

  • Digital Power Meter (High Accuracy Model)

    LS2050 - Lisun Electronics Inc.

    LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.

  • Power System Multimeter

    928A - Arbiter Systems, Inc.

    The Model 928A Power System Multimeter with Floating-Point DSP™ Digital Signal Analysis is an AC Power measurement instrument, providing outstanding performance and flexibility in a small, hand-held package. Not only does the Model 928A measure basic data and power quantities, but it also measures power quality including harmonics, flicker, sags, surges and interruptions. Incorporating a graphic LCD display, serial communications, real time clock and an unprecedented combination of features makes the Model 928A the ideal instrument for the power professional.

  • 3 Phase Power Analyzer

    Model LCD780 - Gopal Electronics

    3 Phase Power Analyzer LCD780 is multi-range power Analyzer with basic 0.07% R+R accuracy. 8 range of voltage, 8 range of current and total 64 range of power and power factor gives more accurate result. Harmonics Measurement Up to 31th order. USB Connectivity + Free Software. Refresh rate : 250ms / 500ms / 1000msThe gap less four-quadrant power measurement technique gives better accuracy at distorted waveforms or AC drive (VFD) operated power supply.

  • PXI-2798, 40 GHz, Dual-Transfer PXI Transfer Switch Module

    782358-01 - NI

    40 GHz, Dual-Transfer PXI Transfer Switch Module—The PXI‑2798 can route RF or microwave signals in automated test applications. Designed to operate with less than 1 dB insertion loss at up to 40 GHz, the PXI‑2798 appears almost invisible to signals at much lower frequencies as well. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2798 is also well-suited for passing high-order harmonics from RF upconverters or routing multiple sources to RF downconverters.

  • PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module

    778572-97 - NI

    26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • Load Pull

    Focus Microwaves

    All Focus tuners use extremely efficient calibration and tuning algorithms and control electronics based on LAN control (iTuner). This is a merger our proven tuner technology with state of the art control electronics to create the latest tuner generation. The on-board micro-processor and tuning firmware form a self-contained and fully calibrated test instrument. The micro-processor inside the tuner accepts ASCII format communication, via an industry standard TCP/IP interface, controls up to nine stepper motors (tuner axes) and executes interpolation and tuning functions for single probe (CCMT) tuners (one probe per frequency range). For tuners with more than one independent probe (MPT) covering the same frequency range to allow for harmonic tuning, external computing power is required, because of the exponentially growing number of combinations of tuner states (slug positions).

  • Voltage Controlled Oscillators

    Pasternack Enterprises, Inc.

    a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.

  • Voltage Variable Attenuators

    Pasternack Enterprises, Inc.

    a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.

  • Electronic Ballast Tester

    WT4000 - Lisun Electronics Inc.

    • Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.

  • Power Meter

    IT9100 Series - I-TECH Electronic Co., Ltd

    The IT9100 power meter can provide the maximum input of 1000 Vrms and 50 Arms and measurement bandwidth of 100 KHz, and can be easily used for measuring thevoltage, current, power, frequency, harmonics and other parameters. The standard configuration includes USB, GPIB, RS232 and LAN communication interfaces and also interfaces for USB-based peripheral devices. Users can save the measured parameters into the external storage medium. The basic voltage and current accuracy is 0.1%. Moreover, the power meter has rich integrating functions, such as the active power. It is widely applied in test of motors, household appliances, UPS, etc.

  • Eco-Power Meters

    Panasonic Automotive & Industrial Systems Europe GmbH

    Main unit expandable with up to 3 expansion unitsEach unit can measure up to 2 circuits (8 circuits with 3 expansion units)Accuracy: 0.2% for V, I and 0.5% for kWhPower quality measurements (THD and harmonic analysis up to the 31st order)Bidirectional energy measurement (energy produced and energy consumed)Demand measurementWeb server functionality integratedNo hub switch required2 Ethernet ports, 1 RS485 interface1 input, 2 outputsHour meter functionalityDIN rail mountingQuick wiring thanks to push-in terminalsIEC61010-1 CAT III

  • AC Power Sources

    CSW Series - AMETEK Programmable Power, Inc.

    The CSW Series represents a new generation of AC/DC power sources that address the increasing demands on test equipment to perform additional functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the Compact CSW Series is capable of handling complex applications that have traditionally required multiple systems. The sleek integrated approach of the CSW avoids cable clutter that is commonly found in test systems. All connections are made internally and the need for digital multimeters, power harmonics analyzers, and current shunts or clamps is eliminated.

  • ICE 3000 Series

    ICE3001 - Pole/Zero

    This subsystem is an agile filter for the SATCOM frequency band, capable of acting as either a receive or a transmit filter. It enables simultaneous operation of multiple transceivers in extreme cosite environments. The ICE3001 provides multiple poles of RF selectivity to reduce broadband noise, harmonics, and spurious signals for either receive or transmit applications. This filter is a highly integrated design incorporating complete Built-in-Test capability. The design has been qualified for military applications. A dual-mount tray is also available as an option for easy incorporation on your platform. Cost-effective modifications are available on the ICE3001.

Get Help