Filter Results By:

Products

Applications

Manufacturers

Harmonic

Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.


Showing results: 286 - 300 of 324 items found.

  • Test Analysis for Land Seismic Systems

    Testif-i Land - Verif-i Ltd

    Testif-i Land is an independent, powerful and cost effective software suite that allows you independently process instruments, source and receiver tests to confirm that the equipment is performing correctly and within specification. The software includes modules to perform comprehensive analysis of vibrator wireline similarity test data. Analysis includes a harmonic intensity plot which can highlight problems such as sub-harmonics which may not be seen on numerical results. Geophone pulse tests can be analysed using the receiver response module and test data from third party geophone testers can be graphed and statistics produced for ease of interpretation.

  • CCFL Ballast Tester

    WT2000A-CCFL - Lisun Electronics Inc.

    This tester is specially designed for analyzing the electrical characteristics of CCFL Electronic Ballast, meets the test requirements in international standard• Input characteristics analysis: measure Vrms, Irms, W, PF, Hz, phase angle Measure THD, 0 to 39th harmonic components, Accuracy: ±(0.4% reading+0.1% range+1 digit)• Output characteristics analysis: measure lamp voltage, lamp current, lamp power, oscillatory frequency, crest factor of lamp current, Accuracy: Class 2• Interface RS-232C provided for easier communication with PC for printing test report

  • sbRIO-9227, Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    781118-01 - NI

    Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The sbRIO‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the sbRIO‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics. Non-enclosed modules are designed for OEM applications.

  • PCI I/O Module for Sound and Vibration

    JSV-4461-PCI - Jumho Electric Corporation

    2-channel ICP analog voltage inputMaximum sample rate: 204.8KS/s; simultaneous acquisitionAnalog-to-digital converter: delta-sigma, 24 bitsPhase Accuracy < 0.05deg@10KHzMaximum analysis bandwidth:96 KHzInput range from ± 42.4 V to ± 316 mV Coupled Mode: AC, DCDigital filter: user-defined low pass, high pass, band pass, band stopDynamic range: 118 dB; harmonic distortion: -107dB; channel crosstalk: -138dBICP current: 0-4 mA, optional 2-channel analog output range: ±10 V; update rate: 204.8 kS/s

  • NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783107-01 - NI

    250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-02 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-01 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • Solid State GaN (Gallium Nitride) Amplifiers

    Fairview Microwave Inc.

    Fairview Microwave’s solid state GaN (Gallium Nitride) power amplifiers (also called SSPAs) feature broad frequency bands ranging from 30 MHz to 7.5 GHz and very high gain levels from 43 to 60 dB. These GaN SSPAs also show impressive harmonic response (-15 to -20 dBc) under worst case conditions. Saturated output power levels range from 10W to 100W with 20% to 35% Power Added Efficiency (PAE). All of our high power solid state GaN amplifiers from Fairview have internally regulated single voltage supplies. Our GaN SSPAs are designed to withstand environmental conditions such as humidity, altitude, shock and vibration with an operating temperature ranges from -40°C to +85°C. Some models are also equipped with integrated heat sinks and cooling fans. Most designs are EAR99.

  • Saluki SE2031 DSP Lock-In Amplifier

    Saluki Technology Inc.

    SE2031 Digital Lock-in Amplifier provides an excellent performance within its bandwidth from 1 mHz to 10 MHz. With the advantage of the latest digital signal processing technology and high-speed 16-bit ADC, SE2031 can easily detect the phase and the magnitude of weak signals overwhelmed by various large noise. The performance of SE2031 is as good as other lock-in amplifier brands, even better in some certain parameters, such as measurement accuracy, SNR, dynamic reserve. Otherwise, SE2031 integrates some special functions like multiple harmonic measurement, which meets the needs of scientific research and industrial application well.

  • Test Compliance

    CTS Series 3.2 - AMETEK Programmable Power, Inc.

    The CTS Series is a complete, turn-key compliance test system for EN IEC 1000-3-2 (Harmonics) Including A14, EN IEC 1000-3-3 (Flicker) and various EN IEC 1000-4 AC immunity tests. Consisting of an AC power source, a power analysis conditioning system (PACS) and a PC based data acquisition system, the CTS provides a complete turn-key solution for IEC testing. The Windows™ based CTS software performs the IEC tests and generates detailed test reports. Comprehensive data files are stored on disk to allow post test analysis.

  • PXI-2598, 26.5 GHz, 50 Ω, Dual-Transfer PXI Transfer Switch Module

    778572-98 - NI

    26.5 GHz, 50 Ω, Dual-Transfer PXI Transfer Switch Module—The PXI‑2598 is a general-purpose switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2598 is also well suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking to predict relay lifetime and reduce unexpected system downtime.

  • Multifunctional Meter

    CPM-80 - Chuan Sheng Electronics Co., Ltd.

    CPM-80 multifunction power analyzer provide high accuracy single phase and three-phase energy measuring and displaying, energy accumulating, power quality analysis, data logging and data communication. CPM-80 series meters are able to measure bidirectional, four quadrants kWh and kVarh. It provides maximum/minimum records for power usage and power demand parameters. Hardware standard built in a RS485 Modbus communication port , 4 Digital inputs, 2 Relay outputs, LCM and 2MB flash for data-logging. In addition , also provide TOU , voltage and current THD, harmonics up to the 63rd and auto wiring change via software .

  • AC Electronic Load

    IT8600 Series - I-TECH Electronic Co., Ltd

    IT8600 is ITECH latest series of AC/DC electronic loads with power range 0~14.4 kVA and adjustable frequency 45 Hz ~ 450 Hz. The unique oscilloscope waveform display function of IT8600's can display input voltage & current as waveform. It is equipped with measurement modes for different parameters such as inrush current, peak value, effective value, PF (power factor). Voltage harmonics measurement capacity is up to 50th. The built-in RS232, GPIB, LAN and USB communication interfaces are for reliable and fast control. IT8600 is the perfect solution for testing UPS, inverters, AC power supplies and relevant AC electronic components etc.

  • Materials Lab XM

    Ametek Scientific Instruments

    The Materials Lab XM product provides a fully integrated reference grade time domain and AC measurement platform. No need to switch sample connections between techniques. Time domain measurements include I-V (current voltage) characterization as well as fast pulse techniques. AC testing techniques include everything from single-sine analysis, to multisine / Fast Fourier Transform for faster low frequency analysis, to harmonics and intermodulation for testing linearity and breakdown of materials. Measurements of electrical impedance spectroscopy (EIS), admittance, permittivity and capacitance are all provided from the XM-studio MTS software platform, together with integrated equivalent circuit analysis functionality.

  • Adjustable High Frequency Reference Ballast

    HCS-109A - Lisun Electronics Inc.

    HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)

Get Help