Filter Results By:

Products

Applications

Manufacturers

Showing results: 211 - 225 of 270 items found.

  • 24 TTL Channels, Enhanced, Programmable I/O

    TL2 - North Atlantic Industries

    Function module TL2 provides 24 channels of TTL/CMOS transceiver functionality as either inputs or outputs. The transistor-transistor logic (TTL) employs transmitters with multiple emitters in gates having more than one input. TTL offers high switching speed and relative immunity to noisy systems. CMOS sensors provide image sensing technology by converting light waves into signals that are small bursts of current. These waves can be light or other electromagnetic radiation.

  • One Port Vector Network Analyser

    TE3001 - TrewMac Systems Pty Ltd

    The TE3001 One Port Vector Network Analyser is built for the professional who understands the calibration process and has a network analysis task to perform. The unit features a larger output signal than the TE3000 for better noise immunity, and is supplied with a 6 piece custom calibration kit to remove the effect of test fixtures and cables. Together, these features make the TE3001 ideal for broadcast and plasma applications that require a length of cable for connection and may be high in noise or interference.

  • NI-9265, 4-Channel C Series Current Output Module

    779334-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • NI-9265, 4-Channel C Series Current Output Module

    783733-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • NI-9265, 4-Channel C Series Current Output Module

    779334-02 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • sbRIO-9263 , Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module

    780876-01 - NI

    Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The sbRIO‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The sbRIO‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.

  • NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle

    865684-01 - NI

    NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9215, cDAQ-9171, and NI-9981 includes the NI-9215 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the NI-9981 Connector for strain relief and operator protection from high-voltage signals. The included NI-9215 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels.

  • C Series Voltage Input Module

    NI

    The C Series Voltage Input Module helps you work with voltage measurement applications. This module features isolation to separate channels from each other, from COM, or from earth ground for safety, noise immunity, and high common-mode voltage range. The module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. You can use included options such as configurable input ranges, output channels, various connectors, and enclosed or non-enclosed modules.The C Series Voltage Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Infrared Motion Sensor

    ENVIROMUX-IMD - Network Technologies Inc

    Registers movement in the area covered. Condition display via LED. Provides immunity from common-mode signals such as the effect of strong hot or cold air currents, variation in ambient temperature, background radiation and acoustic noise. 24 dual-element detection zones for long, mid and short range protections. Surface or corner mounting. Pulse count or single shot triggering. Good RFI protection. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Includes mounting bracket for installing the sensor to a ceiling or wall. Regulatory approvals: CE, RoHS.

  • LETIS

    Laplace Instruments Ltd.

    Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.

  • Low-Noise DC Bias

    Pulse Instruments

    Imaging devices, such as CCDs, IR FPAs, and CMOS image sensors, require DC bias with very low electrical noise to prevent contamination of the image. Image quality can also be enhanced by carefully tuning each bias voltage to extract the maximum signal/noise ratio out of an array. Pulse Instruments has decades of experience providing DC bias supplies with the flexibility required tocharacterize and test a variety of devices while maintaining the noise immunity required for satellite and astronomy applications.

  • Fiber optic thermometer systems

    TS Series - Micronor AG

    Micronor now offers a complete range of fiber optic temperature sensors, probes and interfaces for temperature measurement in challenging environments. TS series fiber optic temperature probes offer immunity to RF and microwave radiation along with wide temperature range, intrinsic safety and non-invasive use. The fiber optic temperature probes can operate over -200°C to +300°C (-328°F to +572°C), and withstand harsh and corrosive environments. Typical fiber optic temperature monitoring applications include:

  • CT / PT Analyzer

    CTPTA-504 - UDEYRAJ ELECTRICALS PRIVATE LIMITED

    UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.

  • C Series Voltage Output Module

    NI

    The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Antenna, Omni-Directional Wideband Discone

    EM-6105 | 10 KHz – 2 GHz - Electro-Metrics Corp.

    The EM-6105 is a broad band collinear array allowing very wide Omni-Directional frequency coverage in a single package. Below approximately 100 MHz, the EM-6105 acts as an active vertical rod which offers 10 to 12 dB more signal handling capability than competitive antennas (overload field strength: 2 V/meter) which greatly reduces intermodulation generated signals in a typical read world RF environment. In the congested spectrum above 100 MHz the antenna is passive and contributes no intermodulation products so the overload point is determined solely by the receiving instrument. This immunity to overload can often make the difference between useful signal output and an indecipherable jumble of spurious products and is accomplished without compromising sensitivity. The antenna collapses for convenient storage and transport. The EM-6105 is supplied with an EM-6106 Battery Pack.

Get Help