Filter Results By:

Products

Applications

Manufacturers

Magnetic

attraction; of opposite polarity objects, magnets to ferrous materials and themselves.

See Also: Magnetic Test, Magnetic Field, Magnetic Head, Magnetic Susceptibility, Magnetic Flux, Magnetic Stripe, Magnetic Permeability, H-field, Core Loss


Showing results: 751 - 765 of 858 items found.

  • Transformer Oil Breakdown Tester

    JY6611S - Kingrun Instrument Co., Ltd.

    JY6611S transformer oil breakdown tester adopts completely new electromagnetic compatibility concept(EMC) which designed to avoid tester crash accident during testing, and also can still work well in high magnetic field.JY6611S also use advanced voltage breakdown control technology which will keep breakdown energy in a very low level, that will avoid pollution to oil sample during testing and make sure the test result are accurate and reliable.

  • Gaussmeter

    GM2 - Alpha Lab, Inc.

    The Model GM2 Measures the strength and polarity of magnetic field up to 30kG when using a standard probes, or 800 gauss (resolution 0.01 gauss) if an HS probe is used. Functions include DC, AC and peak hold along with a user-adjustable alarm which has three modes of operation. DC background field can be subtracted out either by pressing "Relative Zero" or by manually adjusting the offset. The meter includes battery, AC adapter analog output jack and calibration certificate. If a standard probe is used, resolution is 0.1 gauss up to 19,999.9 gauss, which is stronger than the field of any permanent magnet. This 5 digit display allows measurement of tiny difference in strong fields. Above 20kG the meter autoranges to a 30kG range.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • EMI Receiver System

    EMI-9KC/EMI-9KB - Lisun Electronics Inc.

    EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.

  • Hall Effect Measurement system

    HMS-3300 - ECOPIA

    Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.

  • Coaxial Switch, DC to 18 GHz, SPDT, 24 to 30 V Solenoids

    8761B - Keysight Technologies

    The Keysight 8761B is a single-pole, double-throw coaxial switch with excellent electrical and mechanical characteristics for 50 ohm transmission systems operating from dc to 18 GHz. It features broadband operation, long life, low SWR, excellent repeatability, and magnetic latching solenoids. The Keysight 8761B switch is small and lightweight, making it ideal for applications where space is limited. Because of its versatility and excellent electrical performance, it is well suited for automated testing and systems applications.

  • Coaxial Switch, DC to 18 GHz, SPDT, 12 to 15 V Solenoids

    8761A - Keysight Technologies

    The Keysight 8761A is a single-pole, double-throw coaxial switch with excellent electrical and mechanical characteristics for 50 ohm transmission systems operating from dc to 18 GHz. It features broadband operation, long life, low SWR, excellent repeatability, and magnetic latching solenoids. The Keysight 8761A switch is small and lightweight, making it ideal for applications where space is limited. Because of its versatility and excellent electrical performance, it is well suited for automated testing and systems applications.

  • Ultra Lightweight Multi-Spectral Imager

    Recon® V Ultra Lite - Teledyne FLIR

    Fully operational at less than three pounds, the breakthrough Recon V Ultra Lite provides mid-range target detection, recognition, recording and geo-location with an HD color camera and high sensitivity thermal channels. Powered by commercially available AA batteries, the unit has a run time greater than two and a half hours with smart power management. Combining with a highly accurate laser range finder, GPS, digital magnetic compass and intuitive user interface, targets can be quickly located 24/7.

  • Motor/Gasoline Engine RPM Detector

    OM-1500/1200 - Ono Sokki

    The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).

  • Highly Inductive Resistance Meter

    MR 8050 - Schuetz Messtechnik GmbH

    With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.

  • RF Architectural Shielding Products

    LBA Group, Inc

    EMI (Electromagnetic Interference) is often used interchangeably with RFI (Radio Frequency Interference). However, EMI can be any frequency of electromagnetic noise, whereas RFI is a relatively narrow range of electromagnetic noise on the EM spectrum. EMI Shielding can be used to mitigate electric and magnetic radiation across various spaces. Radio Frequency (RF) Shielding can be used to mitigate RFI with specifically designed enclosures that can block RFI. As well, RF Shielding can include application of RF Shielding paints, fabrics, and other materials.

  • Transformer Winding Resistance Meters

    TWA Advanced Series - Amperis sl

    The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.

  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

  • I2C Isolators

    Analog Devices Inc.

    Analog Devices’ family of isolated I2C isolators support a complete isolated I2C interface. This portfolio is based on our iCoupler® chip scale transformer technology. iCoupler is a magnetic isolation technology with functional, performance, size, and power consumption advantages compared to optocouplers. By integrating iCoupler channels with semiconductor circuitry, our technology enables a complete, isolated I2C interface with a small form factor. Our I2C isolators covers applications such as central office switching, networking, and power over Ethernet.

Get Help