Showing results: 1531 - 1545 of 2953 items found.
-
42-788-022-E -
Pickering Interfaces Ltd.
The 40-788-022-E (PXI) and 42-788-022-E (PXIe) are dual failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-042-E -
Pickering Interfaces Ltd.
The 40-788-042-E (PXI) and 42-788-042-E (PXIe) are dual failsafe SP8T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-022-E -
Pickering Interfaces Ltd.
The 40-788-022-E (PXI) and 42-788-022-E (PXIe) are dual failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-222-E -
Pickering Interfaces Ltd.
The 40-788-222-E (PXI) and 42-788-222-E (PXIe) are dual failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-122-E -
Pickering Interfaces Ltd.
The 40-788-122-E (PXI) and 42-788-122-E (PXIe) are dual failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-132-E -
Pickering Interfaces Ltd.
The 40-788-132-E (PXI) and 42-788-132-E (PXIe) are dual failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-012-E -
Pickering Interfaces Ltd.
The 40-788-012-E (PXI) and 42-788-012-E (PXIe) are dual failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-222-E -
Pickering Interfaces Ltd.
The 40-788-222-E (PXI) and 42-788-222-E (PXIe) are dual failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-112-E -
Pickering Interfaces Ltd.
The 40-788-112-E (PXI) and 42-788-112-E (PXIe) are dual failsafe SP10T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-122-E -
Pickering Interfaces Ltd.
The 40-788-122-E (PXI) and 42-788-122-E (PXIe) are dual failsafe SP10T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-132-E -
Pickering Interfaces Ltd.
The 40-788-132-E (PXI) and 42-788-132-E (PXIe) are dual failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-012-E -
Pickering Interfaces Ltd.
The 40-788-012-E (PXI) and 42-788-012-E (PXIe) are dual failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-112-E -
Pickering Interfaces Ltd.
The 40-788-112-E (PXI) and 42-788-112-E (PXIe) are dual failsafe SP10T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-212-E -
Pickering Interfaces Ltd.
The 40-788-212-E (PXI) and 42-788-212-E (PXIe) are dual failsafe SP12T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-212-E -
Pickering Interfaces Ltd.
The 40-788-212-E (PXI) and 42-788-212-E (PXIe) are dual failsafe SP12T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.