42-788-222-TE -
Pickering Interfaces Ltd.
The 40-788-222-TE (PXI) and 42-788-222-TE (PXIe) are dual failsafe SP12T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
40-788-132-TE -
Pickering Interfaces Ltd.
The 40-788-132-TE (PXI) and 42-788-132-TE (PXIe) are dual failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-788-132-TE -
Pickering Interfaces Ltd.
The 40-788-132-TE (PXI) and 42-788-132-TE (PXIe) are dual failsafe SP10T 22 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
42-785C-573-TE -
Pickering Interfaces Ltd.
The 40-785C-573-TE (PXI) and 42-785C-573-TE (PXIe) are triple failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-473-TE -
Pickering Interfaces Ltd.
The 40-785C-473-TE (PXI) and 42-785C-473-TE (PXIe) are triple failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-573-TE -
Pickering Interfaces Ltd.
The 40-785C-573-TE (PXI) and 42-785C-573-TE (PXIe) are triple failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-473-TE -
Pickering Interfaces Ltd.
The 40-785C-473-TE (PXI) and 42-785C-473-TE (PXIe) are triple failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-572-TE -
Pickering Interfaces Ltd.
The 40-785C-572-TE (PXI) and 42-785C-572-TE (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-572-TE -
Pickering Interfaces Ltd.
The 40-785C-572-TE (PXI) and 42-785C-572-TE (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-472-TE -
Pickering Interfaces Ltd.
The 40-785C-472-TE (PXI) and 42-785C-472-TE (PXIe) are dual failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-472-TE -
Pickering Interfaces Ltd.
The 40-785C-472-TE (PXI) and 42-785C-472-TE (PXIe) are dual failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-571-TE -
Pickering Interfaces Ltd.
The 40-785C-571-TE (PXI) and 42-785C-571-TE (PXIe) are single failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-571-TE -
Pickering Interfaces Ltd.
The 40-785C-571-TE (PXI) and 42-785C-571-TE (PXIe) are single failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
40-785C-471-TE -
Pickering Interfaces Ltd.
The 40-785C-471-TE (PXI) and 42-785C-471-TE (PXIe) are single failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
42-785C-471-TE -
Pickering Interfaces Ltd.
The 40-785C-471-TE (PXI) and 42-785C-471-TE (PXIe) are single failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.