Filter Results By:

Products

Applications

Manufacturers

Insulation Test

Check of a materials ability to prevent or reduce transmission.

See Also: Impulse Winding Testers


Showing results: 286 - 300 of 427 items found.

  • Digital H.V. Insulation Tester(12kV)

    7012 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Test insulation resistance up to 20TΩ (20000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 24 insulation test voltages :   500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,   3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,   6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,   9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV ● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) :  ● 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1   CAT IV 600V   EN 61010-2-030    EN 61326-1

  • Multimeter Electronic Test Leads Kit

    AstroAI Corp.

    VERSATILE KIT includes 2 alligator clips with removable insulation, 2 extended range plunger mini-hooks with pass-through banana plugs, 2 heavy duty test probes, 2 42” lead extensionsUNIVERSALLY COMPATIBLE with either 0.16” banana plugs or shrouded banana plugs on all ends

  • Ringwave Generators

    Hilo Test

    Ring wave or oscillatory wave are pulsed onset, damped oscillatory waves as it can be but triggered in low-, medium- and high-voltage systems in data networks as a noise voltage by switching operations, lightning strikes and insulation breakthroughs in cable runs. The Ringwave Immunity tests for electrical equipment are described in the basic EMC standards.

  • Insulation / Continuity Tester Proving Unit

    PU250 - Di-Log

    The PU250 allows simple and quick check of insulation resistance and continuity for all makes of I/R testers.Regular checks outside of the formal calibration process are required for compliance with BS7671 and Part P.Proving unit to enable compliance to the requirement to maintain records of regular checks on the measurement characteristics and accuracy of test instruments.

  • Electrical Safety Multi-Analyzer

    TOS9300 Series - Kikusui Electronics Corp.

    The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • Insulation & Multifunction Tester (LCD Display)

    1153 AI - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1154 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1152 MF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1155 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • High Voltage Tester

    Neutronics Manufacturing Co.

    The AC /DC High Voltage Test Set that we offer to our clients is widely used at electrical maintenance departments and workshops. It is chiefly used to perform routine maintenance of numerous electrical devices and equipment. Apart from that, this product is used to check the quality of insulation provided in any electrical device.

  • Continuity of Insulation Tester (High Voltage Method)

    ZGQ-16B - Shanghai Dean Electrical Co., Ltd

    Executive standard: GB/T4074.5-2008/IEC60851-5;Inspection standard: JB/T4279.13-2008Meet GB/T6109-2008 standard requirementsUsed to test the Insulation continuity (namely the pinhole number of enameled wire sample per unit length) of enameled round wires with nominal conductor diameter ranging from0.05mmto1.60mm;8 level test voltages can be selected by pressing button: 350V, 500V, 750V, 1000V, 1500V, 2000V, 2500V and 3000V;Test length ranging 0~99m;Application of SCM control.Automatically complete test process, display wire testing length and pinhole number;Brushless driving motor, guide pulley and take up pulley are equipotent.The electrode insulation to ground, using high resistance material of non-hygroscopic, no leakage, no tracking, easy to clean, Insulation thickness can ensure long-term 3000V voltage effect.Circuit board is subject to anti-static and moistureproof and long-time aging treatment, has more stable quality and higher durability;

  • High Voltage Tracking Resistance (HVTR)

    UL 746A - National Technical Systems

    The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).

  • Guardian Hipot Tester AC/DC/IR/SCAN

    19050 - Chroma Systems Solutions, Inc.

    The Chroma Guardian 19050 series of Hipot Testers are comprised of three models. The Guardian 19052 is equipped for AC/DC/IR Hipot testing and insulation resistance (IR) measurements. The Guardian 19053 combines both AC and DC Hipot tests and IR measurements with 8HV scan channel capabilities. The Guardian 19054 combines both AC and DC Hipot tests and IR measurements with 4HV scan channel capabilities.

  • Test Sets For Diagnostic Testing

    NEO TELE-TRONIX PVT. LTD

    Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.

Get Help