Showing results: 751 - 765 of 1871 items found.
-
VAPORTRON® -
Buck Research Instruments, LLC
The Vaportron is a humidity generator for calibrating a wide variety of humidity sensors. It is extremely accurate and stable over a wide range of temperatures and humidities. It has numerous options for a wide variety of calibration applications.
-
BMP Testing and Calibration Services Inc.
BMP Testing and Calibration Services, Inc. utilizes the latest thermal measurement equipment to analyze low to medium-conductivity materials, from ceramics, plastics, and polymers to coatings, composites, liquids, and building materials.
-
К2М-100 Series -
Micran Co. Ltd.
*Operating Frequency Range: 100 MHz*Measurements per Connection*All S-Parameter Measurement (256 states)*SOLT Calibration*Measurement Profile Save*Full and Cross Measurement Result Analysis
-
10784A -
Keysight Technologies
The Keysight 10784A Base provides a mounting plate for the 10785A Optics Height Adjuster and Post. The 10784A is an accessory complementing a family of measurement optics and lasers that constitute the 5530 Laser Calibration System.
-
Keysight Technologies
Keysight supplies a wide variety of optics for different calibration measurements. Choose individual optics or a pre-configured kit. Select desired measurement type from the chart or individual optics listed below.
-
Model 26 / 26 H -
Kusam Electrical Industries Limited
The multi-functional field process calibrator with high accuracy and stability, which can provide powerful measurement or output functions & other special functions to meet all the calibration work for field process control.
-
LXinstruments GmbH
Small test system based on the LXinstruments OTP2 system platform. The system is used for assembly, final test and calibration of measuring instruments for chemical analysis in a high mix / medium volume environment.
-
Applied Image, Inc.
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
AD-4530 -
A&D Company, Ltd.
Low cost digital indicator for various applications. Suitable for measurement of load, pressure, torque, tension and more at an affordable price.Digital Zero (DZ) stores zero data at any measurement point. This function can also be used to tare weight. Measurement can simply be restarted when it was interrupted by a loss of power.Power on zero function adjusts to zero when the power is turned on.Digital filter provides stable measurement results.Digital span calibration. Easy calibration just by inputting the rated output of a sensor. No need to use a mass.
-
Mountz Inc.
The EZ-TorQ III makes torque control easier and more available across every aspect of the line from the calibration lab to the assembly station. Highly portable and user friendly, this battery powered torque validation hub can be easily carried around the assembly line to spot check tools as part of a QA program or used at assembly stations for quick and easy torque tool validation and calibration. The new smart phone like touch-screen interface breaks down barriers and ensures quick and easy validation of different ranges as needed.
-
Piranha4 Multispectral -
Teledyne DALSA
The new Piranha4 quadlinear RGB + NIR / Mono cameras provide industry leading speeds to meet future requirements of higher throughput in multi-spectral imaging applications.Based on Teledyne DALSA’s unique CMOS linescan technology, the Piranha4 multi-spectral camera delivers superb color plus near-infrared (NIR) fidelity, spectrally independent outputs, all in a compact footprint and with an easy to use interface. New features include multiple regions of interest for data reduction and regional calibration, sub-pixel spatial correction, white balance and color calibration tools.
-
DA-130N -
MRC ltd.
Measuring method Natural Oscillation typeMeasurement object Liquid sample test materialsRange 0.0000 ~ 2.0000 g/cm3Precision 0.001 g/cm3Resolution 0.0001 g/cm3Temperature range 0 ~ 40.0CTemperature compensation Up to 10 entries for temperature compensation coefficient and converted temperatureAutomatic calibration All density values of pure water needed for auto calibration can be stored.Number of data 1,100 samplesExternal outputPC or Printer can be connected. (not both) IrDA interface is standard equipped. Connection via RS-232C requires optional infrared RS converter (98-029-0007).
-
SolGel Technologies GmbH
The fields of application for photodiode-based UV radiometers are diverse. In their ease of use and ease of use, they represent a very good alternative or supplement to spectrometers. UV sterilization processes or as a measuring device for risk assessment at the workplace. Our devices are subject to strict regulations for production and calibration. Since 2013 we are subject to quality management according to ISO9001. Our calibration laboratory uses PTB traceable references and works according to DAkkS-DKD-MB-3 specifications and the CIE 220: 2016 technical report. Below, we present a selection of our measurement solutions.
-
Eltel Industries
This calibration box is used to routinely check and inspect test sets. The portable calibrator offers one Capacitance, three Tan Delta and four Resistivity values. The maximum operating voltage is 500V AC/DC.
-
VeriGAP -
AMETEK Drexelbrook
Ultrasonic technology is a great choice for high or low-level liquid level measurement requirements in a wide variety of liquids. These ultrasonic sensors require no calibration and are not affected by changes in electrical properties of the material being measured.