Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1381 - 1395 of 1877 items found.

  • Digital to Analog Converter

    Texas Instruments

    20-bit digital-to-analog (D/A) converter offering 20-bit monotonic performance over the specified temperature range. It utilizes delta-sigma technology to achieve inherently linear performance in a small package at very low power. The resolution of the device can be programmed to 20 bits for Full-Scale, settling to 0.003% within 15ms typical, or 16 bits for Full-Scale, settling to 0.012% within 2ms max. The output range is two times the external reference voltage. On-chip calibration circuitry dramatically reduces low offset and gain errors.

  • Inductively Coupled Plasma Spectroscopy (ICP-OES/MS), ICP Analysis Services

    Evans Analytical Group®

    ICP-OES measures the light emitted at element-specific characteristic wavelengths from thermally excited analyte ions . This light emitted is separated and measured in a spectrometer, yielding an intensity measurement that can be converted to an elemental concentration by comparison with calibration standards. ICP-MS (ICP-Mass Spec) measures the masses of the element ions generated by the high temperature argon plasma. The ions created in the plasma are separated by their mass to charge ratios, enabling the identifcation and quantitation of unknown materials. ICP-MS offers extremely high sensitivity (i.e. low detection limits) for a wide range of elements

  • Ozone Meters

    PCE Instruments

    In this section you will find an ozone meter to determine the content of ozone in the air or in the water. The ozone meter is essentially used in environmental technology, but the ozone meter is also used in industrial processes. The ozone meter in water is necessary for water treatment or recycling facilities, such as disinfection processes. The handling of the ozone meter is very simple. The recalibration of the ozone meter can be made by the user at any time. The ozone meter in air requires a more complicated calibration, usually a sensor works for two years with optimal results (little variation) before having to be changed.

  • Plug and Play Potentiometer Input Module

    DSCUSB-PT - Mantracourt Electronics Ltd

    The DSCUSB-PT is a compact, high-precision potentiometer input module; converting a resistance based input (potentiometer) to a digital output. Can be used with resistance based sensors to indicate position, rotation and angle. Aimed at applications which require high accuracy. Simply by plugging the device into a PC, data can be extracted from the potentiometer input to the DSCUSB-PT for a wide range of applications. This is achieved using the DSCUSB Toolkit software, which is a simple configuration tool designed specifically for configuring DSCUSB modules. It allows configuration, calibration, logging and parameter management of the modules.

  • Pocket Digital & Long Stem Thermometers

    ThermoWorks

    Known for their rugged design and Super-Fast® response time, ThermoWorks pocket digital thermometers are in widespread use in restaurants, food plants, labs, and by health inspectors throughout the world. Choose from a variety of designs, probe lengths, and temperature ranges as well as water resistance, NSF certification, and trim calibration functions. All models feature big, easy-to-read digits and fit easily into lab coat, apron, or shirt pockets. Perfect for chefs, line cooks, concrete curing, and food production lines.

  • PRECISION GAUGE

    PX-7 - Dakota Ultrasonics

    The PX-7 is our basic precision gauge model. The PX series are packaged in an aluminum extruded body, with nickel plated aluminum end caps. The PX series gauges are typically used for thin material applications. This gauge has the ability to calibrate to a variety of different materials using a one point calibration option. Some of the features include: Scan feature (allowing the user to scan an area for the minimum thickness), alarm mode (audible & visual), differential mode (+/- from nominal thickness value), and RS232 port out.

  • Range-Doppler Target Generators

    ATG9100 - Innovative Technical Systems

    The ATG-9100 is an example of a laboratory-quality instrument that will simulate complex target motion. Microwave signals from the speed camera enter the instrument through an integrated antenna which is then downconverted and digitized. Target simulation data is added to the digitized signal to provide range and Doppler information. The modified digital data is then converted back to an IF and upconverted to the original microwave frequency of the speed camera and radiated back through the antenna. Since the ATG-9100 can be phase-locked to an external 10 MHz reference standard, this instrument is suitable for use as a calibration standard for speed cameras.

  • Speed Switch

    SCP1000/SCP2000 - Electro-Sensors, Inc.

    Features• Internal sensor• Over-or under-speed config., 1-990 rpm• 1 DPDT relay output (SCP1000), 2 SPDT relay outputs (SCP2000)• Built-in start delay• Dial-in calibration does not require power• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Works with Electro-Sensors magnetic pulser discs / wraps• Explosion proof housing• UL Listed Class I, Div I (C, D) Class II, Div I (E, F, G)

  • Acquisition Of Strain Gauges, Isolated, 18-bit

    APCI-3300-8 - TEAM SOLUTIONS, INC.

    18-bit resolution, unipolar, 16-bit accuracy 8 differential inputs for strain gauges Voltage range 0 to + 2.5 V 8 independant voltage sources for the connected pressure sensors Output voltage for the voltage sources 5 V, 40 mA Gain and offset calibration Calculation of the pressure value through software Programmable gain 16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz 4 digital input channels, 24 V and 3 digital output channels, Open Collector, isolated

  • Air Quality Analysis

    Thermo Fisher Scientific Inc.

    Ambient Gas Monitoring: We offer a variety of analyzers for the ambient monitoring of the criteria pollutant gases, including CO, NOX, SO2, and others such as CH4 and CO2. Source Gas Monitoring (Emissions Monitoring): Experience reliable measurement in your process for emissions compliance every time.Ambient Particulate Monitoring: Experience our monitoring technology and gain the power to do more than just inform.Emissions Calibrators: For continuous monitoring of mercury in exhaust stacks, waste incinerators, and cement kilns, or multi-gas models to control the calibration of gas concentrations.

  • Service Management Software

    CERDAAC - Simco Electronics

    CERDAAC® is an advanced software service that integrates calibration, maintenance, and service management for assets serviced by SIMCO, internal departments, or other service vendors.A secure cloud-based service, CERDAAC is a proven solution that helps thousands of organizations increase efficiency, improve compliance, and reduce costs. CERDAAC provides advanced asset and service workflow management and visibility into service status, program spending, quality compliance, key performance metrics, and more.Learn more about CERDAAC Service Manager and SIMCO Manager, as well as the optional Compliance Module.

  • Digital Miniature Multi Channel Analyzer

    MCA 527 - Baltic Scientific Instruments, Ltd

    Automated base line restorer and threshold adjustmentAutomated or manual pole zero adjustment without oscilloscopeSystem dead time and count rate indicationDead time correctionAutomated spectrum recordingPeak stabilizationBasic analysis functions (energy calibration, FWHM, peak area and integral calculations, spectrum stripping and smoothing)File menu: write/read functions with drive/path - and file pick list functionsSetup menu: ADC, Amplifier, Presets, Memory splitting, MCA mode, MCS mode, Multi spectral recording mode, automated instrument configuration using setup file

  • Bluetooth® Enabled Nitrate & Temperature Pen

    UltrapenX2™ PTBT6 - Myron L Company

    *Nitrate Concentration (ppm N or ppm NO3-) or mV*1 and 2 Point Calibration Options*Proprietary ISE Sensor Design*Built-in Double Junction Reference Electrode*Compatible with EPA Approved Standard Method 4500-NO3-D*Live or Hold Mode – User Selectable*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)

  • pHTestr® 10 Waterproof BNC Pocket pH Tester

    OAKTON Instruments

    Simply choose the electrode best suited for your application, connect the pHTestr BNC 10, calibrate, and measure. Change electrodes to suit your application without having to purchase another meter. Order electrodes separately. Large display and tactile keypad allow for easy calibration along with USA and NIST auto-buffer recognition. Hold function freezes reading on the display for easy recording. Additional features include Valox® sensor housing, self-diagnostic error messages, a battery-life indicator, and an auto-off function to maximize battery life.

  • Moisture Meters

    Traceable Products

    Traceable® Moisture Meter displays material, wood, wood product, and paper moisture content 9.0 to 30.0% with a resolution of 0.1% and an accuracy of ±(4% of the reading plus 5 digits). Memory contains nine material groups such as fiberboard, construction material, and calibrations for 150 types of wood. For all other products, user establishes reference moisture readings. Once programmed, the meter reports directly in percent moisture. Simply touch a material to measure moisture. Takes only seconds. Jumbo-size digits are 1-3/8 inches high.

Get Help