Filter Results By:

Products

Applications

Manufacturers

Analog Input

measurable voltage value.received from a sensor.


Showing results: 616 - 630 of 763 items found.

  • 16-Channel 500kSa/s USB Modular Multifunction Data Acquisition

    U2354A - Keysight Technologies

    The U2354A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2354A to simulate simultaneous analog input acquisition.

  • 16-Channel 250kSa/s USB Modular Multifunction Data Acquisition

    U2352A - Keysight Technologies

    The U2352A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2352A to simulate simultaneous analog input acquisition.

  • ESI(Electronics Systems Integration Unit)

    MS 2004 - Meltronics Systemtech

    The ESI subsystem provides platform interfaces like Gyro and on board Radar Blanking. This unit receives Analog and Digital GYRO inputs from ship and pre- trigger pulses from on board radars of the ship. This unit measures and provides the ship heading data to VARUNA ESM system. It also provides Heading, Roll and Pitch data to the ECM system. This unit also generates band wise composite ESM Rx. Blanking gates and provides all the required interfaces to ESM receiver, ECM System and System Controller units.

  • PXIe-5111, 350 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    785769-11 - NI

    PXIe, 350 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5111 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 350 MHz of analog bandwidth.

  • PXIe-5111, 350 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    785770-01 - NI

    PXIe, 350 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5111 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 350 MHz of analog bandwidth.

  • PXIe-5111, 350 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    785770-11 - NI

    PXIe, 350 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5111 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 350 MHz of analog bandwidth.

  • PXIe-5113, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    786375-11 - NI

    PXIe, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5113 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 500 MHz of analog bandwidth.

  • PXIe-5113, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    786375-01 - NI

    PXIe, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5113 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 500 MHz of analog bandwidth.

  • PXIe-5113, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    786405-01 - NI

    PXIe, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5113 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 500 MHz of analog bandwidth.

  • PXIe-5113, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope

    786405-11 - NI

    PXIe, 500 MHz, 3 GS/s, 8-Bit PXI Oscilloscope—The PXIe-5113 oscilloscope has two channels that sample up to 3 GS/s with flexible and programmable settings for coupling, input impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that facilitates high-speed data throughput and includes analysis functions. This device is ideal for automated and partially automated applications that require flexible measurement configurations and up to 500 MHz of analog bandwidth.

  • 1226 Auto Switch/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new version of the ptf 1226A Auto Switch that includes an additional switch channel (now 3 channels total) of RF, and/or Digital, and/or Time Code, Auto Switching, and a full Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1226 delivers up to thirty six channels of RF, Digital or Time Code frequency and/or timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others.Analog channels include a unique output level monitoring feature to provide remote indication of rms voltage output level.The unit can accept up to three pairs of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity. In addition RF channels include analog level monitoring. If the primary input on any auto switch channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • Test Pattern Generator Delay & AV Sync Analyzer

    VQDM-100 - VideoQ Inc

    Versatile compact and robust multi-purpose tool for R&D and glass-to-glass QA/QC Instant visual-aural quality estimation plus automatic latency, AV sync and 3D LR sync measurement Multi-channel time-line analysis, including video frames continuity testing 4 Light Sensors with vacuum caps, 4 Audio inputs (standard line levels) 2 channels of AV timing analysis, simultaneous measurements of Video and Audio Latencies Real time multi-channel data acquisition via USB port Unique sophisticated set of static and dynamic test patterns up to 1080p@60fps - see more details in separate VQL page Source of VQDM, VQMA2, and VQMA3 Test Patterns for VideoQ Analyzers Multi-format digital and analog AV outputs: HDMI, YPrPb, S-video, SPDIF, LR analog audio Networkable unit, easy expansion with any external USB storage device: live clips, user content, etc.

  • PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit

    APCI-3501-8 - TEAM SOLUTIONS, INC.

    *8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated

  • FMC-HPC ADC Board

    FMC121 - Sundance Multiprocessor Technology Ltd.

    The FMC121 provides two 16-bit A/D channels up to 1Gsps and two 16-bit D/A channels up to 1.4 Gsps data rate with a 2.8 GSPS update rate. The design is based on Texas Instruments’ ADS54J60 Analog-to-Digital converter and Texas Instruments DAC39J84 Digital-to-Analog converter. The sample clock can be supplied externally through a coaxial connection or supplied by an internal clock source (optionally locked to an external reference) for multi-channel synchronization. An external trigger input is available for timing synchronization. The FMC121 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).

  • 6 Digits Process Meter

    A6-PR - Chuan Sheng Electronics Co., Ltd.

    A6-PR 6 Digits Process Meter has been designed with high accuracy measurement, 6 digit display, flexible I/O functions and communication port for process measuring application.There are also build in 4x External Control Inputs, and can option 4x Relay outputs, 1x Analog output and 1x RS485 (Modbus RTU Mode) communication port with multi-functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.There was designed the zero tracking and stable tracking function in programming level.According to the application, user can set the function to get the suitable reading.

Get Help