  • Fault Locator

    VM-510FFL+ - Vivax-Metrotech Corp

    Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.

  • Insulation tester

    C.A 6528 - Chauvin Arnoux Metrix

    The CA 6528 insulation tester is ideal for maintenance and repair operations on electrical equipment such as motors, cables, etc. Thanks to its "hands-free" bag, the CA 6528 insulation tester can be used without any constraints in the field. The shockproof sheath with stand (props) ensure stability on horizontal surfaces.

  • Insulation testers

    MX 409 - Chauvin Arnoux Metrix

    The MX 409 insulation tester is ideal for maintenance and repair operations on electrical equipment such as motors, cables, etc. Thanks to its "hands-free" bag, the MX 409 insulation tester can be used without any constraints in the field. The shockproof sheath with stand (props) ensure stability on horizontal surfaces.

  • Mobile Cable Fault Location System

    Syscompact 2000 - BAUR Prüf- und Messtechnik GmbH

    Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods

  • High-voltage Testers

    Kharkovenergopribor Ltd.

    Operational safety and reliability of electrical equipment and cables directly depend on the dielectric strength of the insulation. Portable and mobile high-voltage testers from KharkovenErgoPribor Ltd. are used for acceptance and operational testing of substation equipment and cable lines, as well as for checking the reliability of personal electrical safety equipment. Our testers range is represented by test systems that allow conducting high-voltage tests with DC and AC voltage, testing polymer insulated cables with very low frequency, testing and locating faults in cable sheath, as well as performing the initial burning of insulation on damaged sections of cable lines.

  • Service Drop Locator

    VM-560 - Vivax-Metrotech Corp

    The VM-560 is a general-purpose locator used to detect buried pipe and cable services in a variety of situations. With a 50/60Hz passive power locating frequency and three active frequencies, the VM-560 locator will meet the requirements of those wishing to detect the presence of active power cables and to trace short ranges. The VM-560 transmitter also has the additional frequency of 8kHz Fault-find so it can be used to detect the presence of ground to sheath faults on cable when used with the VM-510 Stand Alone A-Frame fault locator.

  • 50-Watt Rack Mount Transmitter

    FLS-2 - Vivax-Metrotech Corp

    Fiber optic cables are a critical part of modern life due to the vast amount of data they carry to support businesses, internet users, and emergency services. The cost of losing these services, even temporarily, is immeasurable. The FLS-2 system is designed to assist in locating, monitoring and providing damage prevention to these cables. The FLS-2 high-performance, high-power rack-mounted transmitter is typically mounted in a re-gen staton, customer access point, or central office. The FLS-2 transmits a locate tone on the metallic sheath of the fiber cable over vast distances to ensure the cable can be located quickly and accurately, even in congested areas.

  • Cable Fault Locators

    Fiberinthebox

    Cable Fault Locator is a device used for short circuit faults, cable cuts, resistive faults, intermittent faults, and sheath faults. Fiberinthebox supply cable fault locator for power cable, optical fiberal cable, etc. Fault Location in Power Cable is designed to locate cable faults, pinpointing the fault location, route tracing, cable identification, voltage withstand test and cable information management. It can locate all kinds of cable faults for all voltage level cables, including open circuit, short circuit, low insulation, high insulation and flashover faults, etc. Most power cables were buried underground, invisible, and out of reach, with modern new power cable fault locater, it can find the fault point quickly, solve problems immediately and restore power supply.

  • VLF Testing and Diagnostics Unit

    Viola TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences

  • VLF Testing and Diagnostics Unit

    Frida TD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight

  • Mobile Cable Fault Location System

    BAUR Syscompact 4000 - BAUR Prüf- und Messtechnik GmbH

    Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle

  • Low-Temperature Impact Device

    DWC-1 - Lisun Electronics Inc.

    This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally