Filter Results By:

Products

Applications

Manufacturers

Showing results: 1606 - 1620 of 2618 items found.

  • Plug Socet & Cord Testing

    Educated Design & Development, Inc.

    Flexing Tests: On flexible cables (or cords sets with fitted plugs), electric tools or hand lamps. Meets requirements of standards such as IEC 60335, IEC 60227, IEC 60745 and UL745. This product is for continuous bending tests of cables or cord sets fitted with plugs. The model F39 allows the simultaneous testing of two samples in it's standard version. This not only allows for substantial time savings, but also allows for the testing current circuits to be simplified by looping through the cables.

  • Varactor Tuning Diodes

    Macom Technology Solutions Holdings Inc.

    MACOM’s GaAs and Silicon varactor tuning diodes provide broadband performance ranging from 10 MHz to 70 GHz. They are ideal for high Q filter and VCO electronic tuning circuits and are available in die form, flip chip, plastic and ceramic packaging. These GaAs diodes boast a constant gamma series for higher frequency and high Q applications and silicon abrupt and hyper abrupt series in plastic packaging are suitable for high volume surface mount applications.

  • High-Standard Bench-Top Laser Source

    Shanghai Stone Communication tech Co., Ltd

    These bench-top laser source has built-in high-feature Semi-conductor laser device, it is the SM output, with less than 10MHz plus width. Based on the advanced micro-processor control system, this instrument integrated high precision ATC and ACC(APC) to control the electric circuit, in order to realize the high stable output of the laser device, and make the operation easily and directly. We also can provide user required communication port with the software to realize remote control from the PC.

  • Circulators

    Teledyne Lincoln Microwave

    The most common application of a circulator is as a duplexer, allowing the transmitter and receiver in a radio or radar unit to share a common antenna. Energy is transferred from the RF Source to the antenna during transmit, and from the antenna to the receiver during the receive cycle. In each case the circulator functions to isolate the inactive port from the propagated signal. Most importantly, the transmitter output is not passed to the receiver input, preventing the high transmitter power from damaging the sensitive receiver input circuits.

  • Switch Mainframe

    SW1001 - HIOKI E.E. Corp

    Switch between voltmeter and battery tester while testing. 66 channels max. (2-wire) to 18 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.

  • Copper PCB

    Amitron Corp.

    The Amitron process is capable of producing 20 plus ounces of finished copper and reliably spray coat a protective and consistent solder mask with imaged nomenclature. Amitron utilizes a unique process referred to as "Laminated Deposition". This combination of processes allows extreme copper thickness requirements to become very practical and cost effective. The process utilizes heavy base copper that when placed in our plating and etching systems will deliver consistent and reliable high power circuits.

  • Dip Coating Systems

    Specialty Coating Systems

    SCS Dip Coating systems, which are available in free-standing floor or tabletop models, are specifically designed for production applications that do not require large in-line systems. SCS dip coating systems can be used to apply a range of coatings, as well as photo-resists and solder masks, that are part of printed circuit board applications all with a level of precision that manufacturer's demand. Both SCS models include a host of features that make them an ideal choice for lab and production operations.

  • Super MUTT Deluxe Standard Edition

    #9008-SE - Innovative Products of America

    The Super MUTT places a load on the trailer's electrical circuits to identify wiring problems while providing remote control operation over both air brakes and lights. Built to facilitate a one-man testing operation, the Super MUTT reduces guesswork and inspection time to prevent failures that lead to expensive road calls and citations. The remote control allows for repetitive air brake actuation at each axle to reveal developing problems often missed by normal testing procedures.

  • Switch Mainframe

    SW1002 - HIOKI E.E. Corp

    Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.

  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • High Impedance Active Probes

    12C - Picoprobe

    A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.

  • High-Frequency Probe, 300 kHz to 3 GHz

    85024A - Keysight Technologies

    85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.

  • Phase Monitors

    North Atlantic Industries

    NAI''s AC- and DC-powered Phase Monitors are used to protect three-phase loads from damage due to phase reversals or phase absence. Contacts may be used to disconnect the load or to operate alarm circuits or both. Upon application of power, the output relay energizes if all phases are connected and the phase sequence is ABC. If any phase becomes disconnected or if the phase rotation is abnormal, the relay immediately de-energizes. These monitors are specifically designed for rugged defense and industrial applications.

  • Portable Pinhole Detector

    DZK-18 - Shanghai Dean Electrical Co., Ltd

    Online testing mode: round wireΦ0.05 -Φ5.0, flat wire B side Φ 3 - Φ 18Hand detection mode: round line diameter is not required, flat line width is not requiredTest length: 0-999 m to infinity (set by user)Detection speed: set by the userDefect short circuit current: 25±5uAResponse time: 5 ±1msWorking environment:0-40℃Relative humidity: 75% or lessOperating voltage: AC220V±5%Power consumption: <20W

  • For Overhead Distribution Line Current Tester With Power Flow Direction Record

    MHR-600 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Measuring and recording the average current values & power flow directions in the setting interval.・Easy to use, as an indirect hot-line work tool.・Memorized data can be outputted to USB memoryafter measurement.・For 6.6KV circuit, protection level IP64.

Get Help