Showing results: 1981 - 1995 of 2707 items found.
-
4101 IN -
Standard Electric Works Co., Ltd
● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
-
783467-01 -
NI
51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.
-
783466-01 -
NI
51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.
-
Megger Group Ltd.
Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.
-
JYK II -
Kingrun Instrument Co., Ltd.
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
CRY2100 Series -
CRYSOUND
CRY2100 series noise sensor has tiny structure and is equipped with precision measurement microphone which guarantees a good temperature and humidity characteristics. Noise sensor which integrates with signal conditioning circuit and DSP chip can provide dynamic range up to 110dB, and measure the ambient noises as low as 25 dBA. Noise sensor also has an RS-485 bus interface which can support Modbus RTU protocol, and a 4-20mA analog signal output port.
-
Technology Products
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.
-
North Atlantic Industries
NAI''s AC- and DC-powered Phase Monitors are used to protect three-phase loads from damage due to phase reversals or phase absence. Contacts may be used to disconnect the load or to operate alarm circuits or both. Upon application of power, the output relay energizes if all phases are connected and the phase sequence is ABC. If any phase becomes disconnected or if the phase rotation is abnormal, the relay immediately de-energizes. These monitors are specifically designed for rugged defense and industrial applications.
-
DZK-18 -
Shanghai Dean Electrical Co., Ltd
Online testing mode: round wireΦ0.05 -Φ5.0, flat wire B side Φ 3 - Φ 18Hand detection mode: round line diameter is not required, flat line width is not requiredTest length: 0-999 m to infinity (set by user)Detection speed: set by the userDefect short circuit current: 25±5uAResponse time: 5 ±1msWorking environment:0-40℃Relative humidity: 75% or lessOperating voltage: AC220V±5%Power consumption: <20W
-
MS 1606 -
Meltronics Systemtech
The PowerBus is used to service printed circuit boards, instruments and systems, which has Micro controller / Microprocessor. The PowerBus has RS232 Communication for PC interface. The PowerBus connects to the UUT through the microprocessor / micro controller socket. The UUTs microprocessor / micro controller is removed from the UUT and it is replaced by the PowerBus. The Power Bus adapts microprocessor specific function as pin layouts, status / control function, interrupt handling, timing and memory and I / O addressability.
-
MCH Instruments Co.,Ltd.
Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)
-
Computer Conversions Corporation
1.2VA, 1.5VA, 4.5VA and 5VA Models60 or 400, & 60 and 400 Hz. Models to 22 KHz.Trouble Free Isolated Reference Inputs & Signal OutputsUltra High Efficiency, Low DistortionSelf Powered off the AC Reference Input (DSP Series)Internal Cool AC-Pulsating Supplies (DSP Series)Very Low Loss & Heat DissipationFULLY INTEGRATED, NO EXTERNAL COMPONENTS REQUIREDVery High Resistance to Shock and VibrationHigh Reliability Throughout ImplementationIsolated, Transient, Therrnally & Short Circuit Protected Outputs
-
ENVIROMUX-M-DCS -
Network Technologies Inc
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.
-
Wave3D CMD -
CEMWorks Inc.
Wave3D CMD 'command-line' controlled suite of tools is designed for large-scale parametric modeling of electromagnetic phenomena using High-Performance Computing (HPC) facilities and Cloud computers. The package utilizes the same computational engine based on MLFMA aided Moment Method solution of the Surface-Volume Integral Equation as the Wave3D CAD package. Method of Moment analysis with multilayered media Green's function enables efficient analysis of wide range of 3D planar applications such microstip antennas, microwave circuits, and interconnects.
-
Fairview Microwave Inc.
Fairview Microwave’s single-pole single-throw (SPST) and double-pole double-throw (DPDT) PIN diode waveguide switches feature fully integrated WR-10 and WR-12 waveguide ports and cover popular E-band (60 to 90 GHz) and W-band (75 to 110 GHz) frequencies. Switch circuits integrate low loss Fin-line assemblies with high performance GaAs beam-lead diodes that results in 4 dB insertion loss, greater than 25 dB of Isolation and fast switching speed < 300 nsec.