Filter Results By:

Products

Applications

Manufacturers

Showing results: 2566 - 2580 of 2707 items found.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

  • Single Phase AC Power Source

    APS51 Series - Twintex Electronics Co., Ltd

    ★ Full range adjustable output: Low 1-150V, High 150.1~300V, resolution 0.1V★ Output frequency: 45-250Hz★ Fast output key for 110V/220V and 50Hz/60Hz★ Panel lock function★ 3 sets memories for voltage and frequency settings★ Unlimited rotary knob for voltage and frequency adjustment, minimum step 0.001★ Strong overload capacity, overload 300% within 2s★ Withstand transient current 1.5 times of rated current within 0.1s★ Response time less than 20ms for 100% load and unload★ 5 digits high accuracy LED display for voltage, current, frequency, active power, power factor★ With soft-start function, set voltage rise time (0~99.999s), avoid damage by surge current during load start-up★ Over load, over current, over temperature and short circuit protections★ RS232 interface

  • High Frequency Infrared Carbon and Sulfur Analyzer

    CS-8820 - Wuxi Tianmu Instrument Technology Co., Ltd.

    1. Infrared detector with low noise, high sensitivity and high stability. 2. The modular design of the whole machine improves the reliability of the instrument. 3. The electronic balance is automatically connected. 4, WINDOWS full Chinese operation interface, easy to operate, easy to master. 5. Dynamic display of various data and carbon in the analysis process. 6, measuring linear range is wide, and can be expanded. 7, high-frequency circuit design is reasonable, high-frequency furnace power is adjustable, suitable for different material sample analysis requirements. 8. The automatic cleaning device of the burner can reduce the influence of dust on the analysis results. 9. The burner heating device makes the conversion rate of sulfur tend to be consistent, which improves the stability of sulfur determination. 10, measuring linear range is wide, and can be expanded. 11. The software is fully functional, providing more than forty functions such as file help, system monitoring, channel selection, mathematical statistics, result correction, breakpoint correction, and system diagnosis.

  • ASA240

    Electron Plus

    The ASA240 Analog Signature Analyser will assist you in testing, diagnosing and troubleshooting printed circuit boards without powering them (known as ‘power-off testing’).Connected via USB to a compatible PC running our own free software, with the ASA240 you can easily capture, measure and compare known good signatures (from your ‘golden’ board) with signatures from your suspect board. The built-in gate/bias generator (+/-10V, 100ohm source impedance) can be used to help test active components such as SCR’s, opto-couplers, small relays, TRIAC’s etc. An external dual footswitch can be connected to the ASA200 and can be user configured to control various functions.The built switching matrix (40 x 2) is easily configured from the software and maybe used with adaptors (such as DIP or SO) to speed up testing of boards, or maybe connected to a ‘bed-of-nails’ to facilitate rapid testing of boards in production.With the ASA240 we set out to bring the incredibly powerful technique of Analog Signature Analysis to engineers and repair shops at an affordable price.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • Radiation Microdosimeters

    Teledyne Defense Electronics

    Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.

  • Split Type Ultrasonic Level Gauge

    HR9100D - HighReach Measuring & Controlling System Co.,Ltd

    1. Stable and reliable / We select high-quality modules and key components from the power supply part to select high-stability and reliable devices, which can directly initiate imported instruments. 2, patented technology / one ring patented sound wave intelligent technology software can Intelligent outgoing analysis without any debugging and other special steps, this technology has the function of dynamic thinking, dynamic analysis 3, high precision / sound wave intelligence owned by our company The patented technology greatly improves the accuracy of the ultrasonic level gauge, the Liquid level accuracy reaches ±0.2%, can resist various interference wavesThe instrument is a non-contact instrument, not Direct contact with liquid, so the failure rate is low. The instrument provides a variety of installation methods, users can use this . The Instrument Manual Calibrate to 5. The Protection of The Level of Multiple Protection / IP67 & Instrument Reaches; INPUT and Output Lines All have have Lightning Protection and Short Circuit Protection.

  • Ultrasonic Liquid Level Difference Meter

    HR9100L - HighReach Measuring & Controlling System Co.,Ltd

    1. Stable and reliable / We select high-quality modules and key components from the power supply part to select high-stability and reliable devices, which can directly initiate imported instruments. 2, patented technology / one ring patented sound wave intelligent technology software can Carry out intelligent echo analysis without any debugging and other special steps, this technology has the function of dynamic thinking, dynamic analysis 3, high precision / sound wave intelligence owned by our company The patented technology makes the accuracy of TS-CJ ultrasonic level gauge greatly Improved, the liquid level precision reaches 0.3%, can resist various interference wavesThe instrument is a non-contact type. The meter does not directly contact the liquid, so the fault rate is lower. The meter provides a variety of installation methods, and The user can use this manual to calibrate the meter. 5. The protection level of multiple protection/instrument reaches IP65; all output and input lines have lightning protection and short circuit protection.

  • 40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger

    SD750100G - Zhejiang Sandi Electric Co., Ltd

    40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%

  • Open Source Logic Analyzer

    Logic Pirate - Seeed Technology Inc.

    8 channels 256,000 Samples recording size 20 MHz sampling speed, can potentially be overclocked to 60 MHz No compromise on sample size when combining different speeds or number of channels Simple configurable edge detection triggers on all inputs (simple OR trigger) Configurable ratio of samples from before and after the trigger (rolling sample buffer) 5 V tolerant inputs (LOW-level voltage < 0.8 V, HIGH-level voltage > 2.0 V) About 500 kB/s transfer speed to the PC (256 kSamples take about 0.5 seconds) Data capturing can be stopped from the host software anytime Cross platform host software for Windows, OS X, and Linux DIY-friendly 0603 parts and SOIC packages used on a 2-layer board On board 3.3 V regulator can supply up to 400 mA to an external circuit Tiny 3cm x 3cm PCB Firmware updates via built-in USB bootloader Probe cables and acrylic case available from Seeed Studio Open source PCB (EAGLE) and firmware files

  • High Voltage 50 Ω Pulse Generator

    TLP-8010A - High Power Pulse Instruments GmbH

    *Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components

  • TestCentre

    ARC Technology Solutions

    ARC has experience with complex, commercially available test executives that are available for high volume production needs. Often times, when you don’t need the horsepower of a full featured executive, you are left with creating a specifically defined test program or crafting your own test sequencer. Rather than go down this path and spending your time on architecture, TestCentre brings a simple, yet elegant solution to this all-common problem. Used in many of ARC’s standard test stations, the robust, sequence based architecture of TestCentre, allows you to focus on the testing task at hand. While having some of the more advanced features found in high-end test executives, TestCentre, when mixed with RF analyzers and PXI based test solutions are a great, low cost solution to help solve your everyday testing requirements. Along with TestCentre and an ARC supplied rack-based test platform, your test challenges can be solved in doing circuit card testing, assembly/module level testing, or depot repair troubleshooting tasks.

  • *Pulse Characterization Sensors

    mks Ophir

    Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω

  • Cloud-Ready Physical Verification Signoff Solution

    Pegasus Verification System - Cadence Design Systems

    The Cadence® Pegasus® Verification System is a cloud-ready physical verification signoff solution, which enables engineers to deliver advanced-node integrated circuits (ICs) to market faster. The groundbreaking technology delivers up to 10X improved performance on DRC runs and reduces turnaround time from days to hours. The Pegasus system’s innovative architecture and native cloud processing provides an elastic and flexible computing environment. Customers can now achieve complete full-chip signoff DRC on advanced-node designs in a matter of hours, helping designers deliver products to market faster, or easily run multiple DRC signoff iterations, if needed, at the time of tapeout. The Pegasus system provides a massively parallel architecture. It is the first solution to combine a pipelined infrastructure with stream processing delivering near-linear scalability across 100s of CPUs. The Pegasus system’s gigascale technology enables full-chip signoff DRC in just a few hours versus days. As many designs continue to grow in complexity, the Pegasus system can scale to meet customers’ stringent time-to-market requirements.

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

Get Help