DF-TV7 -
Teledyne Gas & Flame Detection
The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.All MultiFlame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU600 wireless hand-held unit that is approved for use in hazardous areas. The TLU600 can also be used for wireless testing of the optical and output circuits. The TLU600 can also be used for wireless testing of the optical and output circuits.
-
R.R.Transformers & Equipments
Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.
-
HR9100T -
HighReach Measuring & Controlling System Co.,Ltd
1. The circuit design selects high-quality power module components from the power supply part to select high-stability and reliable devices, which can completely replace the same type of imported instruments. 2. The patented sonic intelligent technology software can perform intelligent echo analysis the debugging and the any OTHER Special the without Steps. This Technology has Dynamic Thinking at The Functions of the Analysis and Dynamic. 3. Sound Wave at The Patented Technology of Our Company Makes at The Accuracy of at The Instrument Greatly Improved, at The Precision Liquid Level Reaches 0.25%, and IT CAN Resist various kinds of interference waves.4. This instrument is a kind of non-contact instrument, which does not directly contact with liquid., the instrument has a variety of installation methods. The user can use this manual to calibrate the instrument. 5. All input and output lines Of the instrument have lightning protection and short circuit protection.
-
MicroCalibir -
Teledyne DALSA
The latest advances in the integration of our in-house 12 μm microbolometer pixel technology with a deep-ADC ROIC circuit have resulted in the development of the small and lightweight MicroCalibir™. This compact, low-power uncooled thermal camera platform features the smallest VGA IR core module on the market making it ideal for OEM drones, handhelds, helmet-mounted and vehicular integration products.
-
ETAP Enterprise
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
Scientific Mes-Technik Private Ltd
Scientific offer wide range of function generators from 3 MHz to 10 MHz in general purpose and multifunction. Selection of waveform shapes apart from standard sine, triangle , square to ramp, pulse are available. SM5071 , SM5074 , SM5061 & SM5075 have built-in auto ranging frequency counter. The outputs are protected against short circuits and overload.
-
HIGHVOLT Prüftechnik Dresden GmbH
Is a passive linear circuit that produces an output voltage (Vout) that is a fraction of its input voltage (Vin). Voltage division is the result of distributing the input voltage among the components of the divider. A simple example of a voltage divider is two resistors connected in series, with the input voltage applied across the resistor pair and the output voltage emerging from the connection between them.
-
SERIES S400 TYPE RX I O/ I OACP -
K&S Engineering and Scientific Ltd
The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.
-
RX30/4P -
K&S Engineering and Scientific Ltd
The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.
-
YAVTB000 -
6TL Engineering
When wiring a test fixture, you often have a need to join three or more wires onto the same test point. This module solves this problem, adding test points for manual test probes and a 4 position DIP switch. Circuits 1 and 2 feature up to 5 poles in parallel to increase the space for power supply terminals.
-
E3650 -
Advantest Corp.
Amid the progress of multiple-exposure technology, and the development of finer-pitch and more complicated circuits, as well as increases in the number of masks and the number of measurement points on each mask, the size of wiring patterns formed on photomasks needs to be measured and evaluated stably with high precision. Advantest’s E3600 series meets the needs of state-of-the-art devices with high measurement repeatability and stable throughput.
-
Link Instruments
A Mixed Signal Oscilloscope (MSO) is a combination Logic Analyzer and Oscilloscope. Since all inputs sample simultaneously, it is easy to see the timing relationships of the digital and analog components of your circuit. The extra channels also allow for more complex triggering. All of our MSOs have Oscilloscope triggering, Logic Analyzer triggering, SPI triggering and I2C triggering.
-
M9130 -
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai M9130 optical receiving module is designed for ONU optical fiber network unit. This series of product with perfect detect and remote shutting off function adopts high sensitivity receiving tube and Huatai special low noise matching circuit. It is a kind of high index, low power consumption and high cost performance RFTV optical receiving unit.
-
M9226 -
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai M9226 optical receiving module is designed for ONU optical fiber network unit. This series of product with perfect detect and remote shutting off function adopts high sensitivity receiving tube and Huatai special low noise matching circuit. It is a kind of high index, low power consumption and high cost performance RFTV optical receiving unit.
-
Link Instruments
A Pattern Generator outputs digital data and is used to stimulate circuits. The data can be from user files, previously captured data or from the data creation wizard (editor) in the software. All of our Pattern Generators (digital word generators) are also Logic Analyzers and are controlled with easy-to-use Windows software. Some or all of the outputs are bi-directional and can be used to capture data.