Filter Results By:

Products

Applications

Manufacturers

Calibration References

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services


Showing results: 106 - 120 of 124 items found.

  • Software

    Junction Measurement and Analysis - Materials Development Corporation

    A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.

  • Impedance Standards and Calibrators

    MEATEST, s.r.o.

    Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.

  • Lightning Sensor Breakout

    SEN-39001 - Playing With Fusion Inc

    Breakout board for the AS3935 digital lightning sensor based on the AMS reference design. Includes specially tuned antenna, SPI or I2C interfacing, and a wide 2.4V to 5.5V standard operating range. This innovative sensor is designed to interface with most current development systems and boards, including all current Arduino modules. The breakout board features an inductor (antenna) specially designed for this application, and the board ships fully calibrated. This ensures that you don't have to write a massive back-end to support low-level IC calibration, just focus on your final application!

  • Flow Tester

    Mass Flow - ATEQ Corp.

    At ATEQ, we carry both touch screen and digital mass flow leak testers models. Our products have a simple setup and are easy to operate.Since flow testing is typically used for calibration and leak detection, it is important that you have a reliable, accurate, and user-friendly mass flow air product on hand. Common uses for our mass flow testers include discovering fluid and potential gas leaks, as well as occlusion testing. It is imperative that both objects you test with this type of instrument carry nearly identical reference volumes.

  • pH 700 Benchtop pH Meter

    OAKTON Instruments

    The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.

  • Ultra Low Noise, Rubidium Frequency Standard.

    A10-M - Quartzlock (UK) Ltd.

    Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.

  • Sound Level Calibrator

    TM 100 - Kusam Electrical Industries Limited

    • Standard : Confirms to IEC 942 Class 1.• Output Sound Level : 94dB and 114dB under reference.• Accuracy : ±0.3dB (20°C, 760 mm Hg)• Frequency of 1000 ± 0.1% Hz allows calibration with A / B / C or D weighting networks or linear.• Low Battery Indicator (LED).- Operating Temperature range : -10 ~ +50 C- Storage Temperature range : -40 ~ +65 C (with batteries removed).- Temperature Coefficient : 0 ~ 0.01 dB / C• Calibration of “1 and ½” ceramic microphones.• Altitude Effects : Approx. 0.1 dB decrease for each 2000 feet increase in altitude fromsea level to 12,000 feet elevation, or comparable atmospheric pressure change(approx. every 50 mm of Hg decrease).• Battery : Single 9V transistor Battery. (NEDA 1604)• Battery Life : Approx 100 hours.• Dimension : 48 x 48 x 138mm

  • Spectrum Analysis For E5081A Up To 20 GHz

    S960904B - Keysight Technologies

    The Keysight S960904 spectrum analyzer (SA) software application adds high-performance spectrum analysis to the E5081A ENA-X up to 20 GHz. With fast-stepped FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The application enables simultaneous spectrum measurements using test and reference receivers. The multichannel SA pairs with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application uses source-power and receiver-response calibration and fixture de-embedding, providing highly accurate in-fixture and on-wafer spectrum measurements.

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Fully Automatic Colorimeter

    DRK103C - Shandong Drick Instruments Co., Ltd.

    (1)5 inch TFT color LCD touch screen, the operation is more humanized, new users can be mastered in a short period of time using the method.(2)Simulation of D65 lighting lighting, using CIE1964 complementary color system and CIE1976 (L*a*b*) color space color difference formula.(3)The motherboard brand new design, using the latest technology, CPU uses 32 bits ARM processor,improve the processing speed, the calculated data is more accurate and rapid electromechanical integration design, abandon cumbersome testing process of the artificial hand wheel is rotated, the real implementation of the test program, a determination of the accurate and efficient.(4)Using d/o lighting and observation geometry, diffuse ball diameter 150mm, diameter of the testing hole is 25mm.(5) A light absorber, eliminate the effect of specular reflection.(6)Add printer and imported thermal printer, without the use of ink and color, no noise when working, fast printing speed.(7) Reference sample can be physical, but also for data,? Can store up to ten only memory reference information.(8) Has the memory function, even if the long-term shutdown loss of power, memory zeroing, calibration, standard sample and a reference sample values of the useful information is not lost.(9) Equipped with a standard RS232 interface, can communicate with computer software.

  • Spectrum Analysis For E5081A Up To 44 GHz

    S960907B - Keysight Technologies

    The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Ion 700 Benchtop Meters

    OAKTON Instruments

    Oakton benchtop 700-series meters are designed for use in crowded laboratory settings. Compact footprint of less that 6" x 7" (16 x 18 cm) conserves valuable space, while the large, dual-display LCD provides excellent visibility—even from a distance. Ion 700 meter measures pH, mV, relative mV, ion concentration and temperature. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Models feature five-point pH calibration with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers. Meters additionally feature ion concentration calibration of up to 5 points. Meter features include Auto-Hold, selectable °F or °C measurement, and easy recall of electrode slope or offset. The convenient pull-out quick reference card keeps procedures handy at all times. Use 700-series meters with any pH, ORP, or ISE electrodes with a BNC connector.

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

Get Help