Calibration References

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services


Showing results: 31 - 45 of 124 items found.

  • Portable Calibration System

    HD9120 - Delta OHM S.r.L.

    HD9120 is an acoustic calibrator that, in accordance with the Circular Prot. RU 34143 of 02 December 2011, allows qualified technicians to perform calibrations of sound level meters for comparison with a reference sound level meter.

  • RF Reference Sources

    Fluke Calibration

    The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.

  • Analytical Reference Materials & Standards

    Agilent Technologies

    Agilent, now with former Ultra Scientific, offers a comprehensive portfolio of analytical standards, reference materials and certified reference materials for environmental, food safety, elemental analysis, instrument calibration, tuning mixes, and more.Reference materials and certified reference materials are substances that are tested to be homogenous and have fixed values of its concentrations. These standards are a critical component of your application workflow - from sample prep, instruments, columns, supplies, and services. The success of your analysis depends upon the quality of your reference material. All Agilent standard reference materials have been manufactured to the highest quality in an ISO 9001, ISO 17025 and 17034 accredited facilities to ensure the accuracy of your analyses.If you need a custom reference material, partner with us to design and develop a custom standard to your specifications.

  • Comb Generator, 10 MHz To 110 GHz

    U9391M - Keysight Technologies

    U9391M comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Calibration

    Seibersdorf Labor GmbH

    During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.

  • Dipole Antenna

    AD-100 - Com-Power Corporation

    The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.

  • Portable Battery Coolant/Glycol Refractometer with ATC (°F) -

    Extech RF40 - Extech Instruments Corporation

    This portable battery coolant/glycol Refractometer is easy to operate refract meters provide accurate and repeatable measurements on easy to read scales. The RF40 measures the freezing point of automotive coolants (propylene glycol and ethylene glycol) and indicates the specific gravity of battery acid and provides a quick reference of battery charge condition. Complete with one year warranty, case, calibration screwdriver, plastic pipette and calibration solution.

  • Comb Generator, 10 MHz to 67 GHz

    U9391G - Keysight Technologies

    The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Comb Generator, 10 MHz to 26.5 GHz

    U9391C - Keysight Technologies

    The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Comb Generator, 10 MHz to 50 GHz

    U9391F - Keysight Technologies

    The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.

  • Four Position Meter Test Bench

    TB41 - Calmet Smart Calibration Devices

    The Calmet TB41 Four Position Meter Test Bench is used for calibration and simultaneously testing up to four single and three phase electromechanical and electronic acitve and reactive electricity meters with accuracy referenced to an internal reference meter (class 0.02% or 0.04%).

  • Vector And Scalar Mixer / Converter Measurements

    S95083B - Keysight Technologies

    The Keysight S95083B measurement software includes the scalar mixer / converter plus phase (SMC+Phase) measurement class. It provides fully calibrated conversion gain / loss, relative phase, and absolute group delay measurements of mixers and converters without the need for reference or calibration mixers. Eliminating the calibration mixer requires a U9391C / F / G comb generator and an external DC power supply. A vector mixer characterization (VMC) is also included for measuring group delay of frequency-converting devices. VMC can be used to characterize a user-supplied calibration mixer.

  • Blackbody / Reference Infrared Source

    HGH Infrared Systems

    Blackbodies are reference sources used for testing infrared systems. They are required in industry for calibration of pyrometers, infrared line scanners or cameras. In laboratories, they are part of benches for characterisation of complex optronic systems. HGH offers a wide range of blackbodies to cover all Customers needs.

  • Extractometer

    Dynatest - PASI srl

    *Extractometer used to measure and check the strength of fixing parts*Test carried out with a four-arm wheel or (and) the hydraulic pump with crank*Results on a pointer/digital indicator with peak value*Lightweight and easy to handle*Simple and quick setting up*Appropriate for on site testing*Packaged in a transport case (with a set of optional accessories)*Revolution counter for the crank*Delivered with a calibration results and the copy of the calibration report for the reference standard sensor

  • Meter Test & Calibration

    Kongter Test & Measurement Co., Limited

    Kongter offers a whole line of products for meter test and calibration including portable power source, standard reference meter and meter test system. All products are accredited to the highest production standards with different options of measurement accuracy (class 0.05 and class 0.1).These enable them to cover different applications for test and calibration of different types of energy meters, electric transducers, indicating meters and so on.